Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2025/07/03 11:59
From version 58.4
edited by Karry Zhuang
on 2024/04/20 16:52
on 2024/04/20 16:52
Change comment:
There is no comment for this version
To version 56.2
edited by Karry Zhuang
on 2024/04/20 15:47
on 2024/04/20 15:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,11 +18,6 @@ 18 18 19 19 = 2. Calibrate Digits Readings = 20 20 21 - 22 -The data cable should be connected to the AIS (note: there is no camera on this side), while the computer should be connected on the other side. 23 - 24 -[[image:image-20240420164123-15.jpeg]] [[image:image-20240420164123-16.jpeg]] 25 - 26 26 == 2.1 Calibrate a Water Meter == 27 27 28 28 === 2.1.1 Introduce === ... ... @@ -46,8 +46,6 @@ 46 46 47 47 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 48 48 49 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 50 - 51 51 (% class="box warningmessage" %) 52 52 ((( 53 53 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software. ... ... @@ -71,7 +71,7 @@ 71 71 72 72 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %) 73 73 74 -The computer's drawing tool canbe used to open thelatest bmp image and get the coordinates of the digital wheel dial, as shownbelow. Based on theformatof thedigital wheeldial, wecan obtain each coordinate point of the currentuse dial.The (x,y) coordinate on the imageis locatedat thebottom left corner.67 +The computer's drawing tool should be used to open the most recent bmp image and get the coordinates of the digital wheel dial, as shown in the picture below. Also, we need to obtain each coordinate point of the current dial following the format of said digital wheel dial. It's important to note that the (x,y) coordinate of the mouse on the image corresponds to its bottom left corner. 75 75 76 76 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]](% title="Click and drag to resize" %) 77 77 ... ... @@ -112,8 +112,11 @@ 112 112 113 113 (% title="Click and drag to resize" %) 114 114 115 -== 2.2 Calibration PowerMeter ==108 +== 2.2 Calibration power meter == 116 116 110 + 111 +== 2.1 Calibrate a Power Meter == 112 + 117 117 === 2.2.1 Introduce === 118 118 119 119 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy. ... ... @@ -135,8 +135,6 @@ 135 135 136 136 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 137 137 138 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 139 - 140 140 (% class="box warningmessage" %) 141 141 ((( 142 142 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software. ... ... @@ -158,7 +158,7 @@ 158 158 159 159 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]] 160 160 161 -The computer's drawing tool canbe used to open thelatest bmp image and get the coordinates of the digital wheel dial, as shownbelow. Based on theformatof thedigital wheeldial, wecan obtain each coordinate point of the currentuse dial.The (x,y) coordinate on the imageis locatedat thebottom left corner.155 +The computer's drawing tool should be used to open the most recent bmp image and get the coordinates of the digital wheel dial, as shown in the picture below. Also, we need to obtain each coordinate point of the current dial following the format of said digital wheel dial. It's important to note that the (x,y) coordinate of the mouse on the image corresponds to its bottom left corner. 162 162 163 163 [[image:image-20240420153316-11.png||height="569" width="755"]] 164 164 ... ... @@ -197,7 +197,7 @@ 197 197 [[image:1713595371004-125.png]] 198 198 199 199 200 -== 2.3 Calibration GasMeter ==194 +== 2.3 Calibration gas meter == 201 201 202 202 === 2.3.1 Introduce === 203 203 ... ... @@ -221,8 +221,6 @@ 221 221 222 222 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 223 223 224 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 225 - 226 226 (% class="box warningmessage" %) 227 227 ((( 228 228 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software. ... ... @@ -238,13 +238,13 @@ 238 238 239 239 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]] 240 240 241 -This gasmeter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.233 +This power meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure. 242 242 243 243 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4. 244 244 245 245 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]] 246 246 247 -(% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool canbe used to open thelatest bmp image and get the coordinates of the digital wheel dial, as shownbelow. Based on theformatof thedigital wheeldial, wecan obtain each coordinate point of the currentuse dial.The (x,y) coordinate on the imageis locatedat thebottom left corner.239 +(% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool should be used to open the most recent bmp image and get the coordinates of the digital wheel dial, as shown in the picture below. Also, we need to obtain each coordinate point of the current dial following the format of said digital wheel dial. It's important to note that the (x,y) coordinate of the mouse on the image corresponds to its bottom left corner. 248 248 249 249 [[image:image-20240420153139-10.png||height="530" width="710"]] 250 250 ... ... @@ -256,7 +256,7 @@ 256 256 257 257 The "Digit wheel" option is the digital wheel dial. 258 258 259 -Now we are calibrating the digital wheel face of the gasmeter. Here we select "digit wheel".251 +Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel". 260 260 261 261 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]] 262 262
- image-20240420164123-15.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -229.3 KB - Content
- image-20240420164123-16.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -142.6 KB - Content