Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2024/12/13 11:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,6 +18,11 @@ 18 18 19 19 = 2. Calibrate Digits Readings = 20 20 21 + 22 +The data cable should be connected to the AIS (note: there is no camera on this side), while the computer should be connected on the other side. 23 + 24 +[[image:image-20240420164123-15.jpeg]] [[image:image-20240420164123-16.jpeg]] 25 + 21 21 == 2.1 Calibrate a Water Meter == 22 22 23 23 === 2.1.1 Introduce === ... ... @@ -41,7 +41,7 @@ 41 41 42 42 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 43 43 44 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14 49 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 45 45 46 46 (% class="box warningmessage" %) 47 47 ((( ... ... @@ -107,16 +107,13 @@ 107 107 108 108 (% title="Click and drag to resize" %) 109 109 110 -== 2.2 Calibration powermeter ==115 +== 2.2 Calibration Power Meter == 111 111 112 - 113 -== 2.1 Calibrate a Power Meter == 114 - 115 115 === 2.2.1 Introduce === 116 116 117 117 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy. 118 118 119 -=== 2.2.2 Fix Sensor to a Water Meter ===121 +=== 2.2.2 Fix Sensor to a Power Meter === 120 120 121 121 Do the following with EVB_Board 122 122 Debug Board SW12=[off on] : FT4222H SPI Slave mode ... ... @@ -133,7 +133,7 @@ 133 133 134 134 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 135 135 136 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14 138 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 137 137 138 138 (% class="box warningmessage" %) 139 139 ((( ... ... @@ -195,7 +195,7 @@ 195 195 [[image:1713595371004-125.png]] 196 196 197 197 198 -== 2.3 Calibration gasmeter ==200 +== 2.3 Calibration Gas Meter == 199 199 200 200 === 2.3.1 Introduce === 201 201 ... ... @@ -207,11 +207,11 @@ 207 207 Debug Board SW12=[off on] : FT4222H SPI Slave mode 208 208 AIoT Board SW123456=[off off off off off off] 209 209 210 -(% aria-label="image-20240419174248-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174248-4.png||data-widget="image" height="419" width="419"]](% style="background-image: ; background-image: url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background: rgba(220, 220, 220, 0.5); display: none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)(%%) (% aria-label="image-20240419174159-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174159-3.png||data-widget="image" height="420" width="556"]](% title="Click and drag to resize" %)212 +(% aria-label="image-20240419174248-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174248-4.png||data-widget="image" height="419" width="419"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)(%%) (% aria-label="image-20240419174159-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174159-3.png||data-widget="image" height="420" width="556"]](% title="Click and drag to resize" %) 211 211 212 212 Use a hot glue gun and several sticks to attach for stabilizing the AIS. Adjust the height of the sticks so that the AIS can clearly view the numbers on the gas meter. 213 213 214 -[[image:image-20240420152258-9.jpeg||height=" 931" width="698"]]216 +[[image:image-20240420152258-9.jpeg||height="524" width="698"]] 215 215 216 216 (% title="Click and drag to resize" %) 217 217 ... ... @@ -219,7 +219,7 @@ 219 219 220 220 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 221 221 222 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14 224 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 223 223 224 224 (% class="box warningmessage" %) 225 225 (((