Details

Page properties
Content
... ... @@ -18,6 +18,11 @@
18 18  
19 19  = 2. Calibrate Digits Readings =
20 20  
21 +
22 +The data cable should be connected to the AIS (note: there is no camera on this side), while the computer should be connected on the other side.
23 +
24 +[[image:image-20240420164123-15.jpeg]] [[image:image-20240420164123-16.jpeg]]
25 +
21 21  == 2.1 Calibrate a Water Meter ==
22 22  
23 23  === 2.1.1 Introduce ===
... ... @@ -41,7 +41,7 @@
41 41  
42 42  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
43 43  
44 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
49 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
45 45  
46 46  (% class="box warningmessage" %)
47 47  (((
... ... @@ -107,16 +107,13 @@
107 107  
108 108  (% title="Click and drag to resize" %)​
109 109  
110 -== 2.2 Calibration power meter ==
115 +== 2.2 Calibration Power Meter ==
111 111  
112 -
113 -== 2.1 Calibrate a Power Meter ==
114 -
115 115  === 2.2.1 Introduce ===
116 116  
117 117  This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
118 118  
119 -=== 2.2.2 Fix Sensor to a Water Meter ===
121 +=== 2.2.2 Fix Sensor to a Power Meter ===
120 120  
121 121  Do the following with EVB_Board
122 122  Debug Board SW12=[off on] : FT4222H SPI Slave mode
... ... @@ -133,7 +133,7 @@
133 133  
134 134  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
135 135  
136 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
138 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
137 137  
138 138  (% class="box warningmessage" %)
139 139  (((
... ... @@ -195,7 +195,7 @@
195 195  [[image:1713595371004-125.png]]
196 196  
197 197  
198 -== 2.3 Calibration gas meter ==
200 +== 2.3 Calibration Gas Meter ==
199 199  
200 200  === 2.3.1 Introduce ===
201 201  
... ... @@ -207,11 +207,11 @@
207 207  Debug Board SW12=[off on] : FT4222H SPI Slave mode
208 208  AIoT Board SW123456=[off off off off off off]
209 209  
210 -(% aria-label="image-20240419174248-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174248-4.png||data-widget="image" height="419" width="419"]](% style="background-image: url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background: rgba(220, 220, 220, 0.5); display: none; background-image: url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background: rgba(220, 220, 220, 0.5); display: none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(%%) (% aria-label="image-20240419174159-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174159-3.png||data-widget="image" height="420" width="556"]](% title="Click and drag to resize" %)​
212 +(% aria-label="image-20240419174248-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174248-4.png||data-widget="image" height="419" width="419"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(%%) (% aria-label="image-20240419174159-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174159-3.png||data-widget="image" height="420" width="556"]](% title="Click and drag to resize" %)​
211 211  
212 212  Use a hot glue gun and several sticks to attach  for stabilizing the AIS. Adjust the height of the sticks so that the AIS can clearly view the numbers on the gas meter.
213 213  
214 -[[image:image-20240420152258-9.jpeg||height="931" width="698"]]
216 +[[image:image-20240420152258-9.jpeg||height="524" width="698"]]
215 215  
216 216  (% title="Click and drag to resize" %)​
217 217  
... ... @@ -219,7 +219,7 @@
219 219  
220 220  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
221 221  
222 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
224 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
223 223  
224 224  (% class="box warningmessage" %)
225 225  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0