<
From version < 57.1 >
edited by Karry Zhuang
on 2024/04/20 16:41
To version < 59.1 >
edited by Karry Zhuang
on 2024/04/20 17:30
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,15 +3,12 @@
3 3  
4 4  
5 5  
6 -**Table of Contents:**
7 7  
8 -{{toc/}}
9 9  
10 10  
11 11  
12 12  
13 13  
14 -
15 15  = 1. Overview =
16 16  
17 17  AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
... ... @@ -18,6 +18,11 @@
18 18  
19 19  = 2. Calibrate Digits Readings =
20 20  
18 +
19 +The data cable should be connected to the AIS (note: there is no camera on this side), while the computer should be connected on the other side.
20 +
21 +[[image:image-20240420164123-15.jpeg]] [[image:image-20240420164123-16.jpeg]]
22 +
21 21  == 2.1 Calibrate a Water Meter ==
22 22  
23 23  === 2.1.1 Introduce ===
... ... @@ -41,7 +41,7 @@
41 41  
42 42  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
43 43  
44 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
46 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
45 45  
46 46  (% class="box warningmessage" %)
47 47  (((
... ... @@ -107,16 +107,13 @@
107 107  
108 108  (% title="Click and drag to resize" %)​
109 109  
110 -== 2.2 Calibration power meter ==
112 +== 2.2 Calibration Power Meter ==
111 111  
112 -
113 -== 2.1 Calibrate a Power Meter ==
114 -
115 115  === 2.2.1 Introduce ===
116 116  
117 117  This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
118 118  
119 -=== 2.2.2 Fix Sensor to a Water Meter ===
118 +=== 2.2.2 Fix Sensor to a Power Meter ===
120 120  
121 121  Do the following with EVB_Board
122 122  Debug Board SW12=[off on] : FT4222H SPI Slave mode
... ... @@ -133,7 +133,7 @@
133 133  
134 134  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
135 135  
136 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
135 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
137 137  
138 138  (% class="box warningmessage" %)
139 139  (((
... ... @@ -195,7 +195,7 @@
195 195  [[image:1713595371004-125.png]]
196 196  
197 197  
198 -== 2.3 Calibration gas meter ==
197 +== 2.3 Calibration Gas Meter ==
199 199  
200 200  === 2.3.1 Introduce ===
201 201  
... ... @@ -219,7 +219,7 @@
219 219  
220 220  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
221 221  
222 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
221 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
223 223  
224 224  (% class="box warningmessage" %)
225 225  (((
image-20240420164123-16.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +142.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0