Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2024/12/13 11:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,15 +3,12 @@ 3 3 4 4 5 5 6 -**Table of Contents:** 7 7 8 -{{toc/}} 9 9 10 10 11 11 12 12 13 13 14 - 15 15 = 1. Overview = 16 16 17 17 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. ... ... @@ -18,6 +18,11 @@ 18 18 19 19 = 2. Calibrate Digits Readings = 20 20 18 + 19 +The data cable should be connected to the AIS (note: there is no camera on this side), while the computer should be connected on the other side. 20 + 21 +[[image:image-20240420164123-15.jpeg]] [[image:image-20240420164123-16.jpeg]] 22 + 21 21 == 2.1 Calibrate a Water Meter == 22 22 23 23 === 2.1.1 Introduce === ... ... @@ -41,7 +41,7 @@ 41 41 42 42 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 43 43 44 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14 46 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 45 45 46 46 (% class="box warningmessage" %) 47 47 ((( ... ... @@ -107,16 +107,13 @@ 107 107 108 108 (% title="Click and drag to resize" %) 109 109 110 -== 2.2 Calibration powermeter ==112 +== 2.2 Calibration Power Meter == 111 111 112 - 113 -== 2.1 Calibrate a Power Meter == 114 - 115 115 === 2.2.1 Introduce === 116 116 117 117 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy. 118 118 119 -=== 2.2.2 Fix Sensor to a Water Meter ===118 +=== 2.2.2 Fix Sensor to a Power Meter === 120 120 121 121 Do the following with EVB_Board 122 122 Debug Board SW12=[off on] : FT4222H SPI Slave mode ... ... @@ -133,7 +133,7 @@ 133 133 134 134 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 135 135 136 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14 135 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 137 137 138 138 (% class="box warningmessage" %) 139 139 ((( ... ... @@ -195,7 +195,7 @@ 195 195 [[image:1713595371004-125.png]] 196 196 197 197 198 -== 2.3 Calibration gasmeter ==197 +== 2.3 Calibration Gas Meter == 199 199 200 200 === 2.3.1 Introduce === 201 201 ... ... @@ -219,7 +219,7 @@ 219 219 220 220 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 221 221 222 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14 221 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 223 223 224 224 (% class="box warningmessage" %) 225 225 (((
- image-20240420164123-16.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +142.6 KB - Content