... ... @@ -41,8 +41,6 @@
41 41  
42 42  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
43 43  
44 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
45 -
46 46  (% class="box warningmessage" %)
47 47  (((
48 48  (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
... ... @@ -133,8 +133,6 @@
133 133  
134 134  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
135 135  
136 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
137 -
138 138  (% class="box warningmessage" %)
139 139  (((
140 140  (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
... ... @@ -219,8 +219,6 @@
219 219  
220 220  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
221 221  
222 -Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14
223 -
224 224  (% class="box warningmessage" %)
225 225  (((
226 226  (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
... ... @@ -236,7 +236,7 @@
236 236  
237 237  [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
238 238  
239 -This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
233 +This power meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
240 240  
241 241  If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
242 242  
... ... @@ -254,7 +254,7 @@
254 254  
255 255  The "Digit wheel" option is the digital wheel dial.
256 256  
257 -Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
251 +Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
258 258  
259 259  (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
260 260