Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2025/07/03 11:59
From version 56.4
edited by Karry Zhuang
on 2024/04/20 16:16
on 2024/04/20 16:16
Change comment:
There is no comment for this version
To version 58.5
edited by Karry Zhuang
on 2024/04/20 17:29
on 2024/04/20 17:29
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,6 +18,11 @@ 18 18 19 19 = 2. Calibrate Digits Readings = 20 20 21 + 22 +The data cable should be connected to the AIS (note: there is no camera on this side), while the computer should be connected on the other side. 23 + 24 +[[image:image-20240420164123-15.jpeg]] [[image:image-20240420164123-16.jpeg]] 25 + 21 21 == 2.1 Calibrate a Water Meter == 22 22 23 23 === 2.1.1 Introduce === ... ... @@ -41,6 +41,8 @@ 41 41 42 42 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 43 43 49 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 50 + 44 44 (% class="box warningmessage" %) 45 45 ((( 46 46 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software. ... ... @@ -105,16 +105,13 @@ 105 105 106 106 (% title="Click and drag to resize" %) 107 107 108 -== 2.2 Calibration powermeter ==115 +== 2.2 Calibration Power Meter == 109 109 110 - 111 -== 2.1 Calibrate a Power Meter == 112 - 113 113 === 2.2.1 Introduce === 114 114 115 115 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy. 116 116 117 -=== 2.2.2 Fix Sensor to a Water Meter ===121 +=== 2.2.2 Fix Sensor to a Power Meter === 118 118 119 119 Do the following with EVB_Board 120 120 Debug Board SW12=[off on] : FT4222H SPI Slave mode ... ... @@ -131,6 +131,8 @@ 131 131 132 132 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 133 133 138 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 139 + 134 134 (% class="box warningmessage" %) 135 135 ((( 136 136 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software. ... ... @@ -191,7 +191,7 @@ 191 191 [[image:1713595371004-125.png]] 192 192 193 193 194 -== 2.3 Calibration gasmeter ==200 +== 2.3 Calibration Gas Meter == 195 195 196 196 === 2.3.1 Introduce === 197 197 ... ... @@ -215,6 +215,8 @@ 215 215 216 216 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. 217 217 224 +Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 225 + 218 218 (% class="box warningmessage" %) 219 219 ((( 220 220 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
- image-20240420164123-15.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +229.3 KB - Content
- image-20240420164123-16.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +142.6 KB - Content