Last modified by Karry Zhuang on 2025/07/03 11:59

From version 181.1
edited by Karry Zhuang
on 2024/05/20 11:05
Change comment: There is no comment for this version
To version 185.1
edited by Karry Zhuang
on 2024/12/13 11:29
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,11 +19,11 @@
19 19  = 2. Calibrate Digits Readings =
20 20  
21 21  
22 -The factory default firmware of AIS Sensor is a digital wheel dial. It is recommended that the distance between the camera and the digital wheel dial be 3cm-7cm when installing AIS01-LB. Because the distance is too far, the camera's flash will not be able to illuminate the digital wheel dial to obtain readings.
22 +The factory default firmware of AIS Sensor is a digital wheel dial. It is recommended that the distance between the camera and the digital wheel dial be 3cm-7cm when installing AIS Sensor. Because the distance is too far, the camera's flash will not be able to illuminate the digital wheel dial to obtain readings.
23 23  
24 24  If you are using a [[pointer type dial>>http://wiki.dragino.com/xwiki/bin/view/Main/AI%20Image%20Sensor%20Calibration/#H2.5PressurePointerMeterCalibration]], just adjust the camera to fully see the entire dial.
25 25  
26 -According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
26 +According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=37ofkd06&dl=0 ]].
27 27  
28 28  Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
29 29  
... ... @@ -43,7 +43,7 @@
43 43  
44 44  Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
45 45  
46 -The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
46 +The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=dhm5wem4lgz5nhzmte7egrb0k&e=1&st=0cyy2w2o&dl=0]].
47 47  
48 48  [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
49 49  
... ... @@ -471,7 +471,7 @@
471 471  [[image:1714467112365-676.png]]
472 472  
473 473  
474 -Save as **a.jpg file** and click OK to generate a JPG file.
474 +Save as **image.jpg file** and click OK to generate a JPG file.
475 475  
476 476  [[image:1714467126476-110.png]]
477 477