Last modified by Karry Zhuang on 2025/07/03 11:59

From version 178.1
edited by Karry Zhuang
on 2024/05/16 17:26
Change comment: There is no comment for this version
To version 179.3
edited by Xiaoling
on 2024/05/17 09:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.karry
1 +XWiki.Xiaoling
Content
... ... @@ -1,9 +2,7 @@
1 -
2 2  **Table of Contents:**
3 3  
4 4  {{toc/}}
5 5  
6 -
7 7  
8 8  
9 9  
... ... @@ -14,22 +14,29 @@
14 14  
15 15  = 1. Overview =
16 16  
15 +
17 17  AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
18 18  
18 +
19 19  = 2. Calibrate Digits Readings =
20 20  
21 +
21 21  According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
22 22  
23 23  Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
24 24  
26 +
25 25  == 2.1 Calibrate a Water Meter ==
26 26  
27 27  === 2.1.1 Introduce ===
28 28  
31 +
29 29  This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
30 30  
34 +
31 31  === 2.1.2 Fix Sensor to a Water Meter ===
32 32  
37 +
33 33  The assembly necessitates the use of two screws, two spacers, and this specific device.
34 34  
35 35  Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
... ... @@ -44,23 +44,25 @@
44 44  
45 45  [[image:image-20240428165320-4.gif]]
46 46  
52 +
47 47  2. Proceed by fastening the device using the previously prepared screws and gaskets.
48 48  
49 49  [[image:image-20240428165354-5.gif]]
50 50  
57 +
51 51  3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
52 52  
53 53  [[image:image-20240428165412-6.gif]].
54 54  
62 +
55 55  The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
56 56  
57 57  [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
58 58  
59 59  
60 -
61 -
62 62  === 2.1.3 Calibration ===
63 63  
70 +
64 64  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
65 65  
66 66  For example, Select the corresponding serial port number, here 14.
... ... @@ -70,14 +70,18 @@
70 70  (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
71 71  )))
72 72  
73 -(% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
80 +(% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
74 74  
75 -Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
82 +(% title="Click and drag to resize" %)​
76 76  
77 -(% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]](% title="Click and drag to resize" %)​
84 +Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image" **to display the camera screen.
78 78  
79 -Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
86 +(% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]]
80 80  
88 +(% title="Click and drag to resize" %)​
89 +
90 +Click **"enable Raw" **and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
91 +
81 81  (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
82 82  
83 83  (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
... ... @@ -90,8 +90,10 @@
90 90  
91 91  The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
92 92  
93 -(% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]](% title="Click and drag to resize" %)​
104 +(% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]]
94 94  
106 +(% title="Click and drag to resize" %)​
107 +
95 95  Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
96 96  
97 97  The "Long dial" option is the long hand dial.
... ... @@ -133,16 +133,23 @@
133 133  
134 134  === 2.2.1 Introduce ===
135 135  
149 +
136 136  This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
137 137  
138 -=== 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)​(%%) ===
139 139  
153 +=== 2.2.2 Fix Sensor to a Power Meter ===
154 +
155 +(% class="wikigeneratedid" %)
156 +=== (% title="Click and drag to resize" %)​(%%) ===
157 +
140 140  You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
141 141  
142 142  [[image:image-20240429091325-1.png||height="706" width="535"]]
143 143  
162 +
144 144  === 2.2.3 Calibration ===
145 145  
165 +
146 146  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
147 147  
148 148  For example, Select the corresponding serial port number, here 14.
... ... @@ -152,14 +152,17 @@
152 152  (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
153 153  )))
154 154  
155 -(% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
175 +(% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
156 156  
157 -Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
177 +(% title="Click and drag to resize" %)​
158 158  
179 +Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image"** to display the camera screen.
180 +
159 159  (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
160 160  
161 -Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
162 162  
184 +Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
185 +
163 163  [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
164 164  
165 165  This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
... ... @@ -172,6 +172,7 @@
172 172  
173 173  [[image:image-20240420153316-11.png||height="569" width="755"]]
174 174  
198 +
175 175  (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
176 176  
177 177  The "Long dial" option is the long hand dial.
... ... @@ -211,10 +211,13 @@
211 211  
212 212  === 2.3.1 Introduce ===
213 213  
238 +
214 214  This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
215 215  
241 +
216 216  === 2.3.2 Fix Sensor to a Gas Meter ===
217 217  
244 +
218 218  You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
219 219  
220 220  [[image:image-20240429092436-2.png||height="676" width="519"]]
... ... @@ -222,6 +222,7 @@
222 222  
223 223  === 2.3.3 Calibration ===
224 224  
252 +
225 225  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
226 226  
227 227  For example, Select the corresponding serial port number, here 14.
... ... @@ -285,8 +285,10 @@
285 285  
286 286  [[image:1714358288601-933.png]]
287 287  
316 +
288 288  == 2.4 Digital wheel dial take point coordinate diagram ==
289 289  
319 +
290 290  4  numbers:
291 291  
292 292  (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -313,16 +313,21 @@
313 313  
314 314  === 2.5.1 Introduce ===
315 315  
346 +
316 316  The pressure pointer meter of the example is 1.6MPa range
317 317  
349 +
318 318  === 2.5.2 Fix Sensor to a Power Meter​ ===
319 319  
352 +
320 320  You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
321 321  
322 322  [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
323 323  
357 +
324 324  === 2.5.3 Calibration ===
325 325  
360 +
326 326  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
327 327  
328 328  For example, Select the corresponding serial port number, here 14.
... ... @@ -340,7 +340,7 @@
340 340  [[image:image-20240516163423-3.png]]
341 341  
342 342  
343 -Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
378 +Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
344 344  
345 345  [[image:image-20240516163501-4.png||height="482" width="694"]]
346 346  
... ... @@ -387,16 +387,17 @@
387 387  [[image:image-20240516164153-14.png]]
388 388  
389 389  
390 -
391 391  = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
392 392  
393 -
394 394  == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
395 395  
429 +
396 396  To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
397 397  
398 -=== (% id="cke_bm_3839S" style="display:none" %) (%%)3.1.1 The image date are obtained by serial port ===
399 399  
433 +=== (% style="color:inherit; font-family:inherit; font-size:23px" %)3.1.1 The image date are obtained by serial port(%%) ===
434 +
435 +
400 400  Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
401 401  
402 402  [[image:image-20240514161623-2.png||height="541" width="1439"]]
... ... @@ -408,6 +408,7 @@
408 408  
409 409  === 3.1.2 Combined image ===
410 410  
447 +
411 411  Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
412 412  
413 413  When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
... ... @@ -416,27 +416,27 @@
416 416  
417 417  [[image:1714467040612-103.png||height="134" width="649"]]
418 418  
419 -Click on the edit option to choose and convert.
420 420  
457 +Click on the **edit** option to choose and **convert**.
458 +
421 421  [[image:1714467065723-178.png||height="349" width="762"]]
422 422  
423 -Choose the Hex ASCII->Binary option and then click OK.
424 424  
462 +Choose the **Hex ASCII->Binary** option and then click OK.
463 +
425 425  [[image:1714467089355-837.png||height="366" width="336"]]
426 426  
427 -After the conversion is finished, click on "File" and choose "Save As".
428 428  
467 +After the conversion is finished, click on **"File"** and choose **"Save As"**.
468 +
429 429  [[image:1714467112365-676.png]]
430 430  
431 -Save as a.jpg file and click OK to generate a JPG file.
432 432  
472 +Save as **a.jpg file** and click OK to generate a JPG file.
473 +
433 433  [[image:1714467126476-110.png]]
434 434  
476 +
435 435  Open the saved JPG file to display the image transmitted by the AIS Sensor through the serial port.
436 436  
437 437  [[image:1714467134950-189.png]]
438 -
439 -=== ===
440 -
441 -
442 -= =