Last modified by Karry Zhuang on 2025/07/03 11:59

From version 175.1
edited by Karry Zhuang
on 2024/05/16 16:49
Change comment: There is no comment for this version
To version 179.3
edited by Xiaoling
on 2024/05/17 09:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.karry
1 +XWiki.Xiaoling
Content
... ... @@ -1,32 +1,40 @@
1 -
1 +**Table of Contents:**
2 2  
3 +{{toc/}}
3 3  
4 4  
5 5  
6 -**Table of Contents:**
7 7  
8 -{{toc/}}
9 9  
10 10  
11 11  
12 12  
13 13  
14 -
15 15  = 1. Overview =
16 16  
15 +
17 17  AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
18 18  
18 +
19 19  = 2. Calibrate Digits Readings =
20 20  
21 21  
22 +According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
23 +
24 +Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
25 +
26 +
22 22  == 2.1 Calibrate a Water Meter ==
23 23  
24 24  === 2.1.1 Introduce ===
25 25  
31 +
26 26  This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
27 27  
34 +
28 28  === 2.1.2 Fix Sensor to a Water Meter ===
29 29  
37 +
30 30  The assembly necessitates the use of two screws, two spacers, and this specific device.
31 31  
32 32  Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
... ... @@ -41,23 +41,25 @@
41 41  
42 42  [[image:image-20240428165320-4.gif]]
43 43  
52 +
44 44  2. Proceed by fastening the device using the previously prepared screws and gaskets.
45 45  
46 46  [[image:image-20240428165354-5.gif]]
47 47  
57 +
48 48  3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
49 49  
50 50  [[image:image-20240428165412-6.gif]].
51 51  
62 +
52 52  The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
53 53  
54 54  [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
55 55  
56 56  
57 -
58 -
59 59  === 2.1.3 Calibration ===
60 60  
70 +
61 61  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
62 62  
63 63  For example, Select the corresponding serial port number, here 14.
... ... @@ -67,14 +67,18 @@
67 67  (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
68 68  )))
69 69  
70 -(% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
80 +(% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
71 71  
72 -Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
82 +(% title="Click and drag to resize" %)​
73 73  
74 -(% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]](% title="Click and drag to resize" %)​
84 +Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image" **to display the camera screen.
75 75  
76 -Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
86 +(% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]]
77 77  
88 +(% title="Click and drag to resize" %)​
89 +
90 +Click **"enable Raw" **and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
91 +
78 78  (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
79 79  
80 80  (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
... ... @@ -87,8 +87,10 @@
87 87  
88 88  The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
89 89  
90 -(% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]](% title="Click and drag to resize" %)​
104 +(% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]]
91 91  
106 +(% title="Click and drag to resize" %)​
107 +
92 92  Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
93 93  
94 94  The "Long dial" option is the long hand dial.
... ... @@ -130,16 +130,23 @@
130 130  
131 131  === 2.2.1 Introduce ===
132 132  
149 +
133 133  This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
134 134  
135 -=== 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)​(%%) ===
136 136  
153 +=== 2.2.2 Fix Sensor to a Power Meter ===
154 +
155 +(% class="wikigeneratedid" %)
156 +=== (% title="Click and drag to resize" %)​(%%) ===
157 +
137 137  You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
138 138  
139 139  [[image:image-20240429091325-1.png||height="706" width="535"]]
140 140  
162 +
141 141  === 2.2.3 Calibration ===
142 142  
165 +
143 143  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
144 144  
145 145  For example, Select the corresponding serial port number, here 14.
... ... @@ -149,14 +149,17 @@
149 149  (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
150 150  )))
151 151  
152 -(% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
175 +(% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
153 153  
154 -Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
177 +(% title="Click and drag to resize" %)​
155 155  
179 +Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image"** to display the camera screen.
180 +
156 156  (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
157 157  
158 -Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
159 159  
184 +Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
185 +
160 160  [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
161 161  
162 162  This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
... ... @@ -169,6 +169,7 @@
169 169  
170 170  [[image:image-20240420153316-11.png||height="569" width="755"]]
171 171  
198 +
172 172  (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
173 173  
174 174  The "Long dial" option is the long hand dial.
... ... @@ -208,10 +208,13 @@
208 208  
209 209  === 2.3.1 Introduce ===
210 210  
238 +
211 211  This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
212 212  
241 +
213 213  === 2.3.2 Fix Sensor to a Gas Meter ===
214 214  
244 +
215 215  You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
216 216  
217 217  [[image:image-20240429092436-2.png||height="676" width="519"]]
... ... @@ -219,6 +219,7 @@
219 219  
220 220  === 2.3.3 Calibration ===
221 221  
252 +
222 222  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
223 223  
224 224  For example, Select the corresponding serial port number, here 14.
... ... @@ -282,8 +282,10 @@
282 282  
283 283  [[image:1714358288601-933.png]]
284 284  
316 +
285 285  == 2.4 Digital wheel dial take point coordinate diagram ==
286 286  
319 +
287 287  4  numbers:
288 288  
289 289  (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -310,16 +310,21 @@
310 310  
311 311  === 2.5.1 Introduce ===
312 312  
346 +
313 313  The pressure pointer meter of the example is 1.6MPa range
314 314  
349 +
315 315  === 2.5.2 Fix Sensor to a Power Meter​ ===
316 316  
352 +
317 317  You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
318 318  
319 319  [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
320 320  
357 +
321 321  === 2.5.3 Calibration ===
322 322  
360 +
323 323  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
324 324  
325 325  For example, Select the corresponding serial port number, here 14.
... ... @@ -337,7 +337,7 @@
337 337  [[image:image-20240516163423-3.png]]
338 338  
339 339  
340 -Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
378 +Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
341 341  
342 342  [[image:image-20240516163501-4.png||height="482" width="694"]]
343 343  
... ... @@ -384,16 +384,17 @@
384 384  [[image:image-20240516164153-14.png]]
385 385  
386 386  
387 -
388 388  = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
389 389  
390 -
391 391  == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
392 392  
429 +
393 393  To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
394 394  
395 -=== (% id="cke_bm_3839S" style="display:none" %) (%%)3.1.1 The image date are obtained by serial port ===
396 396  
433 +=== (% style="color:inherit; font-family:inherit; font-size:23px" %)3.1.1 The image date are obtained by serial port(%%) ===
434 +
435 +
397 397  Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
398 398  
399 399  [[image:image-20240514161623-2.png||height="541" width="1439"]]
... ... @@ -405,6 +405,7 @@
405 405  
406 406  === 3.1.2 Combined image ===
407 407  
447 +
408 408  Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
409 409  
410 410  When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
... ... @@ -413,27 +413,27 @@
413 413  
414 414  [[image:1714467040612-103.png||height="134" width="649"]]
415 415  
416 -Click on the edit option to choose and convert.
417 417  
457 +Click on the **edit** option to choose and **convert**.
458 +
418 418  [[image:1714467065723-178.png||height="349" width="762"]]
419 419  
420 -Choose the Hex ASCII->Binary option and then click OK.
421 421  
462 +Choose the **Hex ASCII->Binary** option and then click OK.
463 +
422 422  [[image:1714467089355-837.png||height="366" width="336"]]
423 423  
424 -After the conversion is finished, click on "File" and choose "Save As".
425 425  
467 +After the conversion is finished, click on **"File"** and choose **"Save As"**.
468 +
426 426  [[image:1714467112365-676.png]]
427 427  
428 -Save as a.jpg file and click OK to generate a JPG file.
429 429  
472 +Save as **a.jpg file** and click OK to generate a JPG file.
473 +
430 430  [[image:1714467126476-110.png]]
431 431  
476 +
432 432  Open the saved JPG file to display the image transmitted by the AIS Sensor through the serial port.
433 433  
434 434  [[image:1714467134950-189.png]]
435 -
436 -=== ===
437 -
438 -
439 -= =