Last modified by Karry Zhuang on 2025/07/03 11:59

From version 172.1
edited by Karry Zhuang
on 2024/05/16 16:41
Change comment: Uploaded new attachment "image-20240516164128-13.png", version {1}
To version 175.1
edited by Karry Zhuang
on 2024/05/16 16:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -60,7 +60,7 @@
60 60  
61 61  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
62 62  
63 -Choose the largest number of serial port, for example, Select the corresponding serial port number, here 14.
63 +For example, Select the corresponding serial port number, here 14.
64 64  
65 65  (% class="box warningmessage" %)
66 66  (((
... ... @@ -142,7 +142,7 @@
142 142  
143 143  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
144 144  
145 -Choose the largest number of serial port, for example, Select the corresponding serial port number, here 14.
145 +For example, Select the corresponding serial port number, here 14.
146 146  
147 147  (% class="box warningmessage" %)
148 148  (((
... ... @@ -221,7 +221,7 @@
221 221  
222 222  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
223 223  
224 -Choose the largest number of serial port, for example, Select the corresponding serial port number, here 14.
224 +For example, Select the corresponding serial port number, here 14.
225 225  
226 226  (% class="box warningmessage" %)
227 227  (((
... ... @@ -322,7 +322,7 @@
322 322  
323 323  Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
324 324  
325 -Choose the largest number of serial port, for example, Select the corresponding serial port number, here 14.
325 +For example, Select the corresponding serial port number, here 14.
326 326  
327 327  (% class="box warningmessage" %)
328 328  (((
... ... @@ -372,15 +372,19 @@
372 372  
373 373  5 End point scale value *100
374 374  
375 +After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit.
375 375  
377 +[[image:image-20240516164128-13.png||height="410" width="889"]]
376 376  
377 377  
380 +After the calibration process is completed, The AIS cannot move thereafter to avoid misreading.
378 378  
382 +it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
379 379  
384 +[[image:image-20240516164153-14.png]]
380 380  
381 381  
382 382  
383 -
384 384  = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
385 385  
386 386  
image-20240516164153-14.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +1.9 MB
Content