Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2025/07/03 11:59
From version 166.1
edited by Karry Zhuang
on 2024/05/16 16:39
on 2024/05/16 16:39
Change comment:
Uploaded new attachment "image-20240516163955-8.png", version {1}
To version 177.1
edited by Karry Zhuang
on 2024/05/16 17:26
on 2024/05/16 17:26
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,15 +3,10 @@ 3 3 4 4 5 5 6 -**Table of Contents:** 7 7 8 -{{toc/}} 9 9 10 10 11 11 12 - 13 - 14 - 15 15 = 1. Overview = 16 16 17 17 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. ... ... @@ -18,7 +18,10 @@ 18 18 19 19 = 2. Calibrate Digits Readings = 20 20 16 +According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]]. 21 21 18 +Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]]. 19 + 22 22 == 2.1 Calibrate a Water Meter == 23 23 24 24 === 2.1.1 Introduce === ... ... @@ -60,7 +60,7 @@ 60 60 61 61 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 62 62 63 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.61 +For example, Select the corresponding serial port number, here 14. 64 64 65 65 (% class="box warningmessage" %) 66 66 ((( ... ... @@ -142,7 +142,7 @@ 142 142 143 143 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 144 144 145 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.143 +For example, Select the corresponding serial port number, here 14. 146 146 147 147 (% class="box warningmessage" %) 148 148 ((( ... ... @@ -221,7 +221,7 @@ 221 221 222 222 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 223 223 224 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.222 +For example, Select the corresponding serial port number, here 14. 225 225 226 226 (% class="box warningmessage" %) 227 227 ((( ... ... @@ -322,7 +322,7 @@ 322 322 323 323 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 324 324 325 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.323 +For example, Select the corresponding serial port number, here 14. 326 326 327 327 (% class="box warningmessage" %) 328 328 ((( ... ... @@ -355,10 +355,36 @@ 355 355 [[image:image-20240516163622-6.png||height="648" width="666"]] 356 356 357 357 356 +Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon." 358 358 358 +[[image:image-20240516163910-7.png]] 359 359 360 360 361 +Fill in the values of the coordinates you just got, and it's best to get one and write one 361 361 363 +1 Coordinates of the starting point of the scale 364 + 365 +2 Coordinates of the center point of the dial 366 + 367 +3 Coordinates of the end of the scale 368 + 369 +4 Starting scale value 370 + 371 +5 End point scale value *100 372 + 373 +After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit. 374 + 375 +[[image:image-20240516164128-13.png||height="410" width="889"]] 376 + 377 + 378 +After the calibration process is completed, The AIS cannot move thereafter to avoid misreading. 379 + 380 +it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial. 381 + 382 +[[image:image-20240516164153-14.png]] 383 + 384 + 385 + 362 362 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) = 363 363 364 364
- image-20240516164007-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164028-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +300.5 KB - Content
- image-20240516164052-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164111-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164128-13.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +297.7 KB - Content
- image-20240516164153-14.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.9 MB - Content