Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2025/07/03 11:59
From version 165.1
edited by Karry Zhuang
on 2024/05/16 16:39
on 2024/05/16 16:39
Change comment:
Uploaded new attachment "image-20240516163910-7.png", version {1}
To version 176.1
edited by Karry Zhuang
on 2024/05/16 16:58
on 2024/05/16 16:58
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,7 +18,10 @@ 18 18 19 19 = 2. Calibrate Digits Readings = 20 20 21 +According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]]. 21 21 23 +Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]]. 24 + 22 22 == 2.1 Calibrate a Water Meter == 23 23 24 24 === 2.1.1 Introduce === ... ... @@ -60,7 +60,7 @@ 60 60 61 61 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 62 62 63 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.66 +For example, Select the corresponding serial port number, here 14. 64 64 65 65 (% class="box warningmessage" %) 66 66 ((( ... ... @@ -142,7 +142,7 @@ 142 142 143 143 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 144 144 145 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.148 +For example, Select the corresponding serial port number, here 14. 146 146 147 147 (% class="box warningmessage" %) 148 148 ((( ... ... @@ -221,7 +221,7 @@ 221 221 222 222 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 223 223 224 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.227 +For example, Select the corresponding serial port number, here 14. 225 225 226 226 (% class="box warningmessage" %) 227 227 ((( ... ... @@ -322,7 +322,7 @@ 322 322 323 323 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 324 324 325 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.328 +For example, Select the corresponding serial port number, here 14. 326 326 327 327 (% class="box warningmessage" %) 328 328 ((( ... ... @@ -355,10 +355,36 @@ 355 355 [[image:image-20240516163622-6.png||height="648" width="666"]] 356 356 357 357 361 +Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon." 358 358 363 +[[image:image-20240516163910-7.png]] 359 359 360 360 366 +Fill in the values of the coordinates you just got, and it's best to get one and write one 361 361 368 +1 Coordinates of the starting point of the scale 369 + 370 +2 Coordinates of the center point of the dial 371 + 372 +3 Coordinates of the end of the scale 373 + 374 +4 Starting scale value 375 + 376 +5 End point scale value *100 377 + 378 +After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit. 379 + 380 +[[image:image-20240516164128-13.png||height="410" width="889"]] 381 + 382 + 383 +After the calibration process is completed, The AIS cannot move thereafter to avoid misreading. 384 + 385 +it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial. 386 + 387 +[[image:image-20240516164153-14.png]] 388 + 389 + 390 + 362 362 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) = 363 363 364 364
- image-20240516163955-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164007-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164028-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +300.5 KB - Content
- image-20240516164052-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164111-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164128-13.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +297.7 KB - Content
- image-20240516164153-14.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.9 MB - Content