Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2025/07/03 11:59
From version 164.2
edited by Karry Zhuang
on 2024/05/16 16:38
on 2024/05/16 16:38
Change comment:
There is no comment for this version
To version 175.1
edited by Karry Zhuang
on 2024/05/16 16:49
on 2024/05/16 16:49
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -60,7 +60,7 @@ 60 60 61 61 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 62 62 63 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.63 +For example, Select the corresponding serial port number, here 14. 64 64 65 65 (% class="box warningmessage" %) 66 66 ((( ... ... @@ -142,7 +142,7 @@ 142 142 143 143 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 144 144 145 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.145 +For example, Select the corresponding serial port number, here 14. 146 146 147 147 (% class="box warningmessage" %) 148 148 ((( ... ... @@ -221,7 +221,7 @@ 221 221 222 222 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 223 223 224 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.224 +For example, Select the corresponding serial port number, here 14. 225 225 226 226 (% class="box warningmessage" %) 227 227 ((( ... ... @@ -322,7 +322,7 @@ 322 322 323 323 Open the software [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 324 324 325 - Choose the largestnumber of serial port, for example, Select the corresponding serial port number, here 14.325 +For example, Select the corresponding serial port number, here 14. 326 326 327 327 (% class="box warningmessage" %) 328 328 ((( ... ... @@ -355,10 +355,36 @@ 355 355 [[image:image-20240516163622-6.png||height="648" width="666"]] 356 356 357 357 358 +Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon." 358 358 360 +[[image:image-20240516163910-7.png]] 359 359 360 360 363 +Fill in the values of the coordinates you just got, and it's best to get one and write one 361 361 365 +1 Coordinates of the starting point of the scale 366 + 367 +2 Coordinates of the center point of the dial 368 + 369 +3 Coordinates of the end of the scale 370 + 371 +4 Starting scale value 372 + 373 +5 End point scale value *100 374 + 375 +After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit. 376 + 377 +[[image:image-20240516164128-13.png||height="410" width="889"]] 378 + 379 + 380 +After the calibration process is completed, The AIS cannot move thereafter to avoid misreading. 381 + 382 +it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial. 383 + 384 +[[image:image-20240516164153-14.png]] 385 + 386 + 387 + 362 362 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) = 363 363 364 364
- image-20240516163910-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.8 MB - Content
- image-20240516163955-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164007-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164028-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +300.5 KB - Content
- image-20240516164052-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164111-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20240516164128-13.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +297.7 KB - Content
- image-20240516164153-14.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.9 MB - Content