Last modified by Karry Zhuang on 2025/07/03 11:59

From version 146.2
edited by Karry Zhuang
on 2024/05/06 17:34
Change comment: There is no comment for this version
To version 149.1
edited by Karry Zhuang
on 2024/05/08 14:18
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -339,9 +339,9 @@
339 339  
340 340  **Step 2**:  Use ACT button to activate LHT52 and it will auto join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
341 341  
342 -=== 3.1.1 Uplink Payload (Fport~=5) ===
342 +=== 3.1.1 Uplink Payload (Fport~=2) ===
343 343  
344 -The uplink payload includes totally 14 bytes. Uplink packets use FPORT=5 and (% style="color:#4472c4" %)**every 20 minutes**(%%) send one uplink by default.
344 +The uplink payload includes totally 14 bytes. Uplink packets use FPORT=2 and (% style="color:#4472c4" %)**every 20 minutes**(%%) send one uplink by default.
345 345  
346 346  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:370px" %)
347 347  |=(% style="width: 60px;background-color:#4F81BD;color:white" %)**Size(bytes)(% style="display:none" %) (%%)**|=(% style="width: 60px;background-color:#4F81BD;color:white" %)2|=(% style="width: 80px;background-color:#4F81BD;color:white" %)4|=(% style="width: 80px;background-color:#4F81BD;color:white" %)4|=(% style="width: 60px;background-color:#4F81BD;color:white" %)4
... ... @@ -349,7 +349,7 @@
349 349  
350 350  [[image:1714374026505-898.png||height="200" width="736"]]
351 351  
352 -Payload Example(FPort=5):(% style="background-color:yellow" %)**0D 32 66 29 AF E0 00 00 00 02 00 05 E3 B0**
352 +Payload Example(FPort=2):(% style="background-color:yellow" %)**0D 32 66 29 AF E0 00 00 00 02 00 05 E3 B0**
353 353  
354 354  === 3.1.2 BAT- Battery information ===
355 355  
... ... @@ -509,11 +509,32 @@
509 509  
510 510  = 4. Configure AIS Sensor using AT commands =
511 511  
512 -== 4.1 System Management Commands ==
512 +== 4.1 Configure Methods ==
513 513  
514 -=== 4.1.1 Change Uplink Interval ===
515 515  
515 + configure method:
516 516  
517 +* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
518 +* AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
519 +* LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
520 +
521 +== 4.2 General Commands ==
522 +
523 +
524 +These commands are to configure:
525 +
526 +* General system settings like: uplink interval.
527 +* LoRaWAN protocol & radio related command.
528 +
529 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
530 +
531 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
532 +
533 +== 4.3 Commands special design for AIS Sensor ==
534 +
535 +=== 4.3.1 Change Uplink Interval ===
536 +
537 +
517 517  Feature: Change LoRaWAN End Node Transmit Interval.
518 518  
519 519  
... ... @@ -546,7 +546,7 @@
546 546  
547 547  (% style="display:none" %) (%%)
548 548  
549 -== 4.1.2 Request the server to send an ACK ==
570 +== 4.3.2 Request the server to send an ACK ==
550 550  
551 551  
552 552  (% style="color:blue" %)**AT Command: AT+PNACKMD**
... ... @@ -568,7 +568,7 @@
568 568  0x34 00  ~/~/Same As AT+PNACKMD=0
569 569  
570 570  
571 -=== 4.1.3 Set Interrupt Mode ===
592 +=== 4.3.3 Set Interrupt Mode ===
572 572  
573 573  
574 574  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -605,9 +605,11 @@
605 605  * Example 2: Downlink Payload: 06000003  **~-~-->**  AT+INTMOD1=3
606 606  * Example 3: Downlink Payload: 06000102  **~-~-->**  AT+INTMOD2=2
607 607  
608 -== 4.1.4 Clock logging (Since firmware version v1.2.1) ==
629 +=== ===
609 609  
631 +=== 4.3.4 Clock logging (Since firmware version v1.2.1) ===
610 610  
633 +
611 611  Sometimes when we deploy lots of end nodes in field. We want all sensors sample data at the same time, and upload these data together for analyze. In such case, we can use clock loging feature.
612 612  
613 613  We can use this command to set the start time of data recording and the time interval to meet the requirements of the specific collection time of data.