From version < 9.1 >
edited by Edwin Chen
on 2023/04/16 13:43
To version < 11.1 >
edited by Edwin Chen
on 2023/04/16 17:51
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -319,8 +319,6 @@
319 319  [[Humidity>>path:#HHumidity:]]
320 320  )))
321 321  
322 -
323 -
324 324  ==== (% style="color:#4472c4" %)**Battery:**(%%) ====
325 325  
326 326  Sensor Battery Level.
... ... @@ -364,24 +364,26 @@
364 364  
365 365  == 2.4 Payload Decoder file ==
366 366  
367 -In TTN, use can add a custom payload so it shows friendly
365 +In TTN, use can add a custom payload so it shows friendly reading
368 368  
369 -In the page **Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder** to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B >>https://github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B]]
367 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from:
370 370  
369 +[[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B >>https://github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B]]
371 371  
371 +
372 372  == 2.5 Datalog Feature ==
373 373  
374 374  
375 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, D2x-LB will store the reading for future retrieving purposes.
375 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes.
376 376  
377 377  
378 378  === 2.5.1 Ways to get datalog via LoRaWAN ===
379 379  
380 380  
381 -Set [[PNACKMD=1>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.13AutoSendNone-ACKmessages]], D2x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,D2x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
381 +Set [[PNACKMD=1>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.13AutoSendNone-ACKmessages]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
382 382  
383 -* a) D2x-LB will do an ACK check for data records sending to make sure every data arrive server.
384 -* b) D2x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but D2x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if D2x-LB gets a ACK, D2x-LB will consider there is a network connection and resend all NONE-ACK Message.
383 +* a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server.
384 +* b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.
385 385  
386 386  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
387 387  
... ... @@ -390,7 +390,7 @@
390 390  === 2.5.2 Unix TimeStamp ===
391 391  
392 392  
393 -LHT65N uses Unix TimeStamp format based on
393 +S31x-LB uses Unix TimeStamp format based on
394 394  
395 395  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="image-20220523001219-11.png" height="97" width="627"]]
396 396  
... ... @@ -406,17 +406,17 @@
406 406  === 2.5.3 Set Device Time ===
407 407  
408 408  
409 -User need to set SYNCMOD=1 to enable sync time via MAC command.
409 +User need to set **SYNCMOD=1** to enable sync time via MAC command.
410 410  
411 -Once D2x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to D2x-LB. If D2x-LB fails to get the time from the server, D2x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
411 +Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
412 412  
413 413  **Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
414 414  
415 415  
416 -=== 2.5.4 Datalog Uplink payload  FPORT~=3 ===
416 +=== 2.5.4 Datalog Uplink payload (FPORT~=3) ===
417 417  
418 418  
419 -The Datalog poll reply uplink will use below payload format.
419 +The Datalog uplinks will use below payload format.
420 420  
421 421  **Retrieval data payload:**
422 422  
... ... @@ -464,7 +464,7 @@
464 464  
465 465   Stop time: 60066DA7= time 21/1/19 05:27:03
466 466  
467 -**LHT65N will uplink this payload.**
467 +**S31x-LB will uplink this payload.**
468 468  
469 469  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-13.png?width=727&height=421&rev=1.1||alt="image-20220523001219-13.png" height="421" width="727"]]
470 470  
... ... @@ -490,7 +490,7 @@
490 490  == 2.6 Temperature Alarm Feature ==
491 491  
492 492  
493 -D2x-LB work flow with Alarm feature.
493 +S31x-LB work flow with Alarm feature.
494 494  
495 495  
496 496  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-D20-D22-D23%20LoRaWAN%20Temperature%20Sensor%20User%20Manual/WebHome/image-20220623090437-1.png?rev=1.1||alt="image-20220623090437-1.png"]]
... ... @@ -500,7 +500,7 @@
500 500  == 2.7 Frequency Plans ==
501 501  
502 502  
503 -The D2x-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
503 +The S31x-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
504 504  
505 505  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
506 506  
... ... @@ -510,19 +510,18 @@
510 510  
511 511  **Firmware download link:**
512 512  
513 -[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
513 +[[https:~~/~~/www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0>>https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]
514 514  
515 515  
516 += 3. Configure S31x-LB =
516 516  
517 -= 3. Configure D2x-LB =
518 -
519 519  == 3.1 Configure Methods: ==
520 520  
521 521  
522 -D2x-LB supports below configure method:
521 +S31x-LB supports below configure method:
523 523  
524 524  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
525 -* AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]].
524 +* AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
526 526  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
527 527  
528 528  == 3.2 General Commands ==
... ... @@ -538,10 +538,10 @@
538 538  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
539 539  
540 540  
541 -== 3.3 Commands special design for D2x-LB ==
540 +== 3.3 Commands special design for S31x-LB ==
542 542  
543 543  
544 -These commands only valid for D2x-LB, as below:
543 +These commands only valid for S31x-LB, as below:
545 545  
546 546  
547 547  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -582,69 +582,64 @@
582 582  Sensor will upload Device Status via FPORT=5. See payload section for detail.
583 583  
584 584  
585 -=== 3.3.3 Set Alarm Thredhold ===
584 +=== 3.3.3 Set Temperature Alarm Threshold: ===
586 586  
586 +* **AT Command:**
587 587  
588 -(% style="color:#4472c4" %)**1.  Set for All Probes:**
588 +**AT+SHTEMP=min,max**
589 589  
590 -(% style="color:#037691" %)**AT+18ALARM=min,max**
590 +* When min=0, and max≠0, Alarm higher than max
591 +* When min≠0, and max=0, Alarm lower than min
592 +* When min≠0 and max≠0, Alarm higher than max or lower than min
591 591  
592 -* When min=0, and max≠0, Alarm trigger when higher than max
593 -* When min≠0, and max=0, Alarm trigger when lower than min
594 -* When min≠0 and max≠0, Alarm trigger when higher than max or lower than min
594 +Example:
595 595  
596 -**Example:**
596 + AT+SHTEMP=0,30   ~/~/ Alarm when temperature higher than 30.
597 597  
598 - AT+18ALARM=-10,30  ~/~/ Alarm when < -10 or higher than 30.
598 +* **Downlink Payload:**
599 599  
600 +**0x(0C 01 00 1E)**  ~/~/Set AT+SHTEMP=0,30
600 600  
601 -* (% style="color:#037691" %)**Downlink Payload:**
602 +**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)**
602 602  
603 -0x(0B F6 1E)   ~/~/ Same as AT+18ALARM=-10,30
604 604  
605 -(note: 0x1E= 30, 0xF6 means: 0xF6-0x100 = -10)
605 +=== 3.3.4 Set Humidity Alarm Threshold: ===
606 606  
607 +* **AT Command:**
607 607  
608 -(% style="color:#4472c4" %)**2.  Set for Separate Probe:**
609 +**AT+SHHUM=min,max**
609 609  
610 -(% style="color:#037691" %)**AT+18ALARM=min,max,index**
611 +* When min=0, and max≠0, Alarm higher than max
612 +* When min≠0, and max=0, Alarm lower than min
613 +* When min≠0 and max≠0, Alarm higher than max or lower than min
611 611  
612 -Index:
615 +Example:
613 613  
614 -* 1: Temperature_Red
615 -* 2: Temperature_White
616 -* 3: Temperature_Black
617 + AT+SHHUM=70,0   ~/~/ Alarm when humidity lower than 70%.
617 617  
618 -**Example:**
619 +* **Downlink Payload:**
619 619  
620 - AT+18ALARM=-10,30,1   ~/~/ Alarm when temperature_red < -10 or higher than 30.
621 +**0x(0C 02 46 00)**  ~/~/Set AT+SHTHUM=70,0
621 621  
623 +**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))**
622 622  
623 -* (% style="color:#037691" %)**Downlink Payload:**
624 624  
625 -0x(0B F6 1E 01)   ~/~/ Same as AT+18ALARM=-10,30,1
626 +=== 3.3.5 Set Alarm Interval: ===
626 626  
627 -(note: 0x1E= 30, 0xF6 means: 0xF6-0x100 = -10)
628 -
629 -
630 -=== 3.3.4 Set Alarm Interval ===
631 -
632 -
633 633  The shortest time of two Alarm packet. (unit: min)
634 634  
635 -* (% style="color:#037691" %)**AT Command:**
630 +* **AT Command:**
636 636  
637 -AT+ATDC=30  ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes.
632 +**AT+ATDC=30**  ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes.
638 638  
634 +* **Downlink Payload:**
639 639  
640 -* (% style="color:#037691" %)**Downlink Payload:**
636 +**0x(0D 00 1E)**     **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes
641 641  
642 -0x(0D 00 1E)     **~-~-->** Set AT+ATDC=0x 00 1E = 30 minutes
643 643  
639 +=== 3.3.6 Get Alarm settings  (什么FPORT?) ===
644 644  
645 -=== 3.3.5 Get Alarm settings  (什么FPORT?) ===
646 646  
647 -
648 648  Send a LoRaWAN downlink to ask device send Alarm settings.
649 649  
650 650  * (% style="color:#037691" %)**Downlink Payload:  **(%%)0x0E 01
... ... @@ -658,9 +658,11 @@
658 658  
659 659  * Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message.
660 660  
661 -=== 3.3.6 Set Interrupt Mode ===
662 662  
663 663  
657 +=== 3.3.7 Set Interrupt Mode ===
658 +
659 +
664 664  Feature, Set Interrupt mode for GPIO_EXIT.
665 665  
666 666  (% style="color:blue" %)**AT Command: AT+INTMOD**
... ... @@ -689,10 +689,11 @@
689 689  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
690 690  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
691 691  
688 +
692 692  = 4. Battery & Power Consumption =
693 693  
694 694  
695 -D2x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
692 +S31x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
696 696  
697 697  [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
698 698  
... ... @@ -708,7 +708,7 @@
708 708  == 6.1 How to use AT Command via UART to access device? ==
709 709  
710 710  
711 -See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
708 +See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]
712 712  
713 713  
714 714  == 6.2 How to update firmware via UART port? ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0