From version < 73.1 >
edited by Bei Jinggeng
on 2023/11/13 17:56
To version < 73.4 >
edited by Xiaoling
on 2023/11/15 08:52
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -54,6 +54,8 @@
54 54  * Downlink to change configure
55 55  * 8500mAh Battery for long term use
56 56  
57 +
58 +
57 57  == 1.3 Specification ==
58 58  
59 59  
... ... @@ -99,11 +99,15 @@
99 99  * Sleep Mode: 5uA @ 3.3v
100 100  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
101 101  
104 +
105 +
102 102  == 1.4 Applications ==
103 103  
104 104  
105 105  * Smart Agriculture
106 106  
111 +
112 +
107 107  == 1.5 Sleep mode and working mode ==
108 108  
109 109  
... ... @@ -131,6 +131,8 @@
131 131  )))
132 132  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
133 133  
140 +
141 +
134 134  == 1.7 BLE connection ==
135 135  
136 136  
... ... @@ -146,13 +146,9 @@
146 146  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
147 147  
148 148  
149 -== 1.8 Pin Definitions ==
157 +== 1.8 Mechanical ==
150 150  
151 151  
152 -
153 -== 1.9 Mechanical ==
154 -
155 -
156 156  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]]
157 157  
158 158  
... ... @@ -324,7 +324,6 @@
324 324  Valid Message Type:
325 325  )))
326 326  
327 -
328 328  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:496px" %)
329 329  |=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Message Type Code**|=(% style="width: 163px;background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 173px;background-color:#D9E2F3;color:#0070C0" %)**Payload**
330 330  |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
... ... @@ -331,12 +331,13 @@
331 331  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
332 332  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
333 333  
337 +
338 +
334 334  === 2.3.7 Decode payload in The Things Network ===
335 335  
336 336  
337 337  While using TTN network, you can add the payload format to decode the payload.
338 338  
339 -
340 340  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654592762713-715.png?rev=1.1||alt="1654592762713-715.png"]]
341 341  
342 342  (((
... ... @@ -556,19 +556,20 @@
556 556  
557 557  == 2.7 Calibration ==
558 558  
559 -Step1 : Clean probe
560 560  
564 +(% style="color:blue" %)**Step1 :**(%%)** Clean probe**
565 +
561 561  user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks new, users can clean it to remove hydrochloric acid or other liquids from the surface.
562 562  
563 -Step2 : Immerse the sensor in ph buffer solution to make the sensor values stable
568 +(% style="color:blue" %)**Step2 :**(%%)** Immerse the sensor in ph buffer solution to make the sensor values stable**
564 564  
565 565  (((
566 566  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
567 567  
568 -Note:Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer
573 +(% style="color:red" %)**Note:Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer**
569 569  
570 570  
571 -Step3 : The numerically stable sensors were calibrated using commands
576 +(% style="color:blue" %)**Step3 :**(%%)** The numerically stable sensors were calibrated using commands**
572 572  )))
573 573  
574 574  (((
... ... @@ -610,7 +610,6 @@
610 610  
611 611  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
612 612  
613 -
614 614  When the command is successfully used, the node sends a uplink.
615 615  This is the payload for uplink
616 616  
... ... @@ -639,10 +639,8 @@
639 639  
640 640  * Reply to non-confirmed packet: 14 00
641 641  
642 -Step4:
646 +(% style="color:blue" %)**Step4:**(%%)**After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration.**
643 643  
644 -After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration
645 -
646 646  Examples:
647 647  After using the command AT+PH=9 in 9.18ph buffer
648 648  The readout returned by the sensor in 9.18ph buffer should be pH=9
... ... @@ -669,6 +669,8 @@
669 669  
670 670  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
671 671  
674 +
675 +
672 672  == 3.2 General Commands ==
673 673  
674 674  
... ... @@ -769,6 +769,8 @@
769 769  
770 770  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
771 771  
776 +
777 +
772 772  === 3.3.3 Calibrate Sensor ===
773 773  
774 774  
... ... @@ -879,6 +879,8 @@
879 879  
880 880  * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
881 881  
888 +
889 +
882 882  = 6. FAQ =
883 883  
884 884  == 6.1  AT Commands input doesn't work ==
... ... @@ -910,6 +910,8 @@
910 910  
911 911  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
912 912  
921 +
922 +
913 913  = 8. ​Packing Info =
914 914  
915 915  
... ... @@ -927,6 +927,8 @@
927 927  
928 928  * Weight / pcs : g
929 929  
940 +
941 +
930 930  = 9. Support =
931 931  
932 932  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0