... ... @@ -54,6 +54,7 @@
54 54  * Downlink to change configure
55 55  * 8500mAh Battery for long term use
56 56  
57 +
57 57  == 1.3 Specification ==
58 58  
59 59  
... ... @@ -99,6 +99,7 @@
99 99  * Sleep Mode: 5uA @ 3.3v
100 100  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
101 101  
103 +
102 102  == 1.4 Applications ==
103 103  
104 104  
... ... @@ -131,6 +131,7 @@
131 131  )))
132 132  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
133 133  
136 +
134 134  == 1.7 BLE connection ==
135 135  
136 136  
... ... @@ -331,6 +331,7 @@
331 331  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
332 332  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
333 333  
337 +
334 334  === 2.3.7 Decode payload in The Things Network ===
335 335  
336 336  
... ... @@ -558,7 +558,8 @@
558 558  
559 559  Step1 : Clean probe
560 560  
561 -user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks new, users can clean it to remove hydrochloric acid or other liquids from the surface.
565 +user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
566 +
562 562  
563 563  Step2 : Immerse the sensor in ph buffer solution to make the sensor values stable
564 564  
... ... @@ -565,9 +565,7 @@
565 565  (((
566 566  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
567 567  
568 -Note:Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer
569 569  
570 -
571 571  Step3 : The numerically stable sensors were calibrated using commands
572 572  )))
573 573  
... ... @@ -600,17 +600,7 @@
600 600  )))
601 601  )))
602 602  
603 -To use the AT COMMAND, refer to this link:
604 604  
605 -* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
606 -
607 -* AT Command via UART Connection : See [[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
608 -
609 -To use Downlink, take TTN as an example, please refer to this link:
610 -
611 -* LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
612 -
613 -
614 614  When the command is successfully used, the node sends a uplink.
615 615  This is the payload for uplink
616 616  
... ... @@ -639,15 +639,12 @@
639 639  
640 640  * Reply to non-confirmed packet: 14 00
641 641  
635 +
642 642  Step4:
643 643  
644 644  After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration
645 645  
646 -Examples:
647 -After using the command AT+PH=9 in 9.18ph buffer
648 -The readout returned by the sensor in 9.18ph buffer should be pH=9
649 649  
650 -
651 651  == 2.8 Frequency Plans ==
652 652  
653 653  
... ... @@ -669,6 +669,7 @@
669 669  
670 670  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
671 671  
662 +
672 672  == 3.2 General Commands ==
673 673  
674 674  
... ... @@ -769,6 +769,7 @@
769 769  
770 770  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
771 771  
763 +
772 772  === 3.3.3 Calibrate Sensor ===
773 773  
774 774  
... ... @@ -879,6 +879,7 @@
879 879  
880 880  * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
881 881  
874 +
882 882  = 6. FAQ =
883 883  
884 884  == 6.1  AT Commands input doesn't work ==
... ... @@ -910,6 +910,7 @@
910 910  
911 911  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
912 912  
906 +
913 913  = 8. ​Packing Info =
914 914  
915 915  
... ... @@ -927,6 +927,7 @@
927 927  
928 928  * Weight / pcs : g
929 929  
924 +
930 930  = 9. Support =
931 931  
932 932  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0