Changes for page SPH01-LB -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2024/01/15 09:36
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,6 +54,7 @@ 54 54 * Downlink to change configure 55 55 * 8500mAh Battery for long term use 56 56 57 + 57 57 == 1.3 Specification == 58 58 59 59 ... ... @@ -99,6 +99,7 @@ 99 99 * Sleep Mode: 5uA @ 3.3v 100 100 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 101 101 103 + 102 102 == 1.4 Applications == 103 103 104 104 ... ... @@ -131,6 +131,7 @@ 131 131 ))) 132 132 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 133 133 136 + 134 134 == 1.7 BLE connection == 135 135 136 136 ... ... @@ -331,6 +331,7 @@ 331 331 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 332 332 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 333 333 337 + 334 334 === 2.3.7 Decode payload in The Things Network === 335 335 336 336 ... ... @@ -558,7 +558,8 @@ 558 558 559 559 Step1 : Clean probe 560 560 561 -user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks new, users can clean it to remove hydrochloric acid or other liquids from the surface. 565 +user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 566 + 562 562 563 563 Step2 : Immerse the sensor in ph buffer solution to make the sensor values stable 564 564 ... ... @@ -565,9 +565,7 @@ 565 565 ((( 566 566 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 567 567 568 -Note:Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer 569 569 570 - 571 571 Step3 : The numerically stable sensors were calibrated using commands 572 572 ))) 573 573 ... ... @@ -600,17 +600,7 @@ 600 600 ))) 601 601 ))) 602 602 603 -To use the AT COMMAND, refer to this link: 604 604 605 -* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 606 - 607 -* AT Command via UART Connection : See [[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 608 - 609 -To use Downlink, take TTN as an example, please refer to this link: 610 - 611 -* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 612 - 613 - 614 614 When the command is successfully used, the node sends a uplink. 615 615 This is the payload for uplink 616 616 ... ... @@ -639,15 +639,12 @@ 639 639 640 640 * Reply to non-confirmed packet: 14 00 641 641 635 + 642 642 Step4: 643 643 644 644 After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration 645 645 646 -Examples: 647 -After using the command AT+PH=9 in 9.18ph buffer 648 -The readout returned by the sensor in 9.18ph buffer should be pH=9 649 649 650 - 651 651 == 2.8 Frequency Plans == 652 652 653 653 ... ... @@ -669,6 +669,7 @@ 669 669 670 670 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 671 671 662 + 672 672 == 3.2 General Commands == 673 673 674 674 ... ... @@ -769,6 +769,7 @@ 769 769 770 770 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 771 771 763 + 772 772 === 3.3.3 Calibrate Sensor === 773 773 774 774 ... ... @@ -879,6 +879,7 @@ 879 879 880 880 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 881 881 874 + 882 882 = 6. FAQ = 883 883 884 884 == 6.1 AT Commands input doesn't work == ... ... @@ -910,6 +910,7 @@ 910 910 911 911 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 912 912 906 + 913 913 = 8. Packing Info = 914 914 915 915 ... ... @@ -927,6 +927,7 @@ 927 927 928 928 * Weight / pcs : g 929 929 924 + 930 930 = 9. Support = 931 931 932 932