Changes for page SPH01-LB -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2024/01/15 09:36
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -1,5 +1,4 @@ 1 -(% style="text-align:center" %) 2 -[[image:image-20230530181207-3.jpeg||height="552" width="552"]] 1 +[[image:image-20230530181207-3.jpeg||height="503" width="503"]] [[image:image-20240105101301-1.jpeg||height="513" width="436"]] 3 3 4 4 5 5 ... ... @@ -106,6 +106,7 @@ 106 106 107 107 * Smart Agriculture 108 108 108 + 109 109 == 1.5 Sleep mode and working mode == 110 110 111 111 ... ... @@ -149,13 +149,9 @@ 149 149 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 150 150 151 151 152 -== 1.8 Pin Definitions==152 +== 1.8 Mechanical == 153 153 154 154 155 - 156 -== 1.9 Mechanical == 157 - 158 - 159 159 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 160 160 161 161 ... ... @@ -327,7 +327,6 @@ 327 327 Valid Message Type: 328 328 ))) 329 329 330 - 331 331 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:496px" %) 332 332 |=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Message Type Code**|=(% style="width: 163px;background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 173px;background-color:#D9E2F3;color:#0070C0" %)**Payload** 333 333 |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]] ... ... @@ -340,7 +340,6 @@ 340 340 341 341 While using TTN network, you can add the payload format to decode the payload. 342 342 343 - 344 344 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654592762713-715.png?rev=1.1||alt="1654592762713-715.png"]] 345 345 346 346 ((( ... ... @@ -560,18 +560,20 @@ 560 560 561 561 == 2.7 Calibration == 562 562 563 -Step1 : Clean probe 564 564 565 -user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 566 - 558 +(% style="color:blue" %)**Step1 :**(%%)** Clean probe** 567 567 568 - Step2 : Immersethe sensor inphbuffer solution tomakethe sensorvaluesstable560 +user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks new, users can clean it to remove hydrochloric acid or other liquids from the surface. 569 569 562 +(% style="color:blue" %)**Step2 :**(%%)** Immerse the sensor in ph buffer solution to make the sensor values stable** 563 + 570 570 ((( 571 571 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 572 572 567 +(% style="color:red" %)**Note:Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer** 573 573 574 -Step3 : The numerically stable sensors were calibrated using commands 569 + 570 +(% style="color:blue" %)**Step3 :**(%%)** The numerically stable sensors were calibrated using commands** 575 575 ))) 576 576 577 577 ((( ... ... @@ -603,7 +603,16 @@ 603 603 ))) 604 604 ))) 605 605 602 +To use the AT COMMAND, refer to this link: 606 606 604 +* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 605 + 606 +* AT Command via UART Connection : See [[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 607 + 608 +To use Downlink, take TTN as an example, please refer to this link: 609 + 610 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 611 + 607 607 When the command is successfully used, the node sends a uplink. 608 608 This is the payload for uplink 609 609 ... ... @@ -632,12 +632,13 @@ 632 632 633 633 * Reply to non-confirmed packet: 14 00 634 634 640 +(% style="color:blue" %)**Step4:**(%%)**After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration.** 635 635 636 -Step4: 642 +Examples: 643 +After using the command AT+PH=9 in 9.18ph buffer 644 +The readout returned by the sensor in 9.18ph buffer should be pH=9 637 637 638 -After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration 639 639 640 - 641 641 == 2.8 Frequency Plans == 642 642 643 643
- image-20240105101301-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +96.9 KB - Content