From version < 72.1 >
edited by Bei Jinggeng
on 2023/11/06 17:11
To version < 71.5 >
edited by Xiaoling
on 2023/08/09 16:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -54,7 +54,6 @@
54 54  * Downlink to change configure
55 55  * 8500mAh Battery for long term use
56 56  
57 -
58 58  == 1.3 Specification ==
59 59  
60 60  
... ... @@ -100,7 +100,6 @@
100 100  * Sleep Mode: 5uA @ 3.3v
101 101  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
102 102  
103 -
104 104  == 1.4 Applications ==
105 105  
106 106  
... ... @@ -133,7 +133,6 @@
133 133  )))
134 134  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
135 135  
136 -
137 137  == 1.7 BLE connection ==
138 138  
139 139  
... ... @@ -334,7 +334,6 @@
334 334  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
335 335  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
336 336  
337 -
338 338  === 2.3.7 Decode payload in The Things Network ===
339 339  
340 340  
... ... @@ -560,22 +560,13 @@
560 560  
561 561  == 2.7 Calibration ==
562 562  
563 -Step1 : Clean probe
564 564  
565 -user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
566 -
567 -
568 -Step2 : Immerse the sensor in ph buffer solution to make the sensor values stable
569 -
570 570  (((
571 571  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
572 -
573 -
574 -Step3 : The numerically stable sensors were calibrated using commands
575 575  )))
576 576  
577 577  (((
578 - User can use below command to calibrate.
565 +After stable, user can use below command to calibrate.
579 579  
580 580  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:520px" %)
581 581  |(% style="background-color:#d9e2f3; color:#0070c0; width:120px" %)**pH buffer solution**|(% style="background-color:#d9e2f3; color:#0070c0; width:150px" %)**AT Command to calibrate**|(% style="background-color:#d9e2f3; color:#0070c0; width:150px" %)**Downlink Command**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**Read Cal Value**
... ... @@ -604,9 +604,6 @@
604 604  )))
605 605  
606 606  
607 -When the command is successfully used, the node sends a uplink.
608 -This is the payload for uplink
609 -
610 610  (% style="color:#037691" %)**Calibration Payload**
611 611  
612 612  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
... ... @@ -632,12 +632,6 @@
632 632  
633 633  * Reply to non-confirmed packet: 14 00
634 634  
635 -
636 -Step4:
637 -
638 -After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration
639 -
640 -
641 641  == 2.8 Frequency Plans ==
642 642  
643 643  
... ... @@ -659,7 +659,6 @@
659 659  
660 660  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
661 661  
662 -
663 663  == 3.2 General Commands ==
664 664  
665 665  
... ... @@ -760,7 +760,6 @@
760 760  
761 761  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
762 762  
763 -
764 764  === 3.3.3 Calibrate Sensor ===
765 765  
766 766  
... ... @@ -871,7 +871,6 @@
871 871  
872 872  * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
873 873  
874 -
875 875  = 6. FAQ =
876 876  
877 877  == 6.1  AT Commands input doesn't work ==
... ... @@ -903,7 +903,6 @@
903 903  
904 904  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
905 905  
906 -
907 907  = 8. ​Packing Info =
908 908  
909 909  
... ... @@ -921,7 +921,6 @@
921 921  
922 922  * Weight / pcs : g
923 923  
924 -
925 925  = 9. Support =
926 926  
927 927  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0