From version < 71.7 >
edited by Xiaoling
on 2023/08/09 16:46
To version < 73.4 >
edited by Xiaoling
on 2023/11/15 08:52
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -108,6 +108,8 @@
108 108  
109 109  * Smart Agriculture
110 110  
111 +
112 +
111 111  == 1.5 Sleep mode and working mode ==
112 112  
113 113  
... ... @@ -152,13 +152,9 @@
152 152  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
153 153  
154 154  
155 -== 1.8 Pin Definitions ==
157 +== 1.8 Mechanical ==
156 156  
157 157  
158 -
159 -== 1.9 Mechanical ==
160 -
161 -
162 162  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]]
163 163  
164 164  
... ... @@ -330,7 +330,6 @@
330 330  Valid Message Type:
331 331  )))
332 332  
333 -
334 334  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:496px" %)
335 335  |=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Message Type Code**|=(% style="width: 163px;background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 173px;background-color:#D9E2F3;color:#0070C0" %)**Payload**
336 336  |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
... ... @@ -344,7 +344,6 @@
344 344  
345 345  While using TTN network, you can add the payload format to decode the payload.
346 346  
347 -
348 348  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654592762713-715.png?rev=1.1||alt="1654592762713-715.png"]]
349 349  
350 350  (((
... ... @@ -565,12 +565,23 @@
565 565  == 2.7 Calibration ==
566 566  
567 567  
564 +(% style="color:blue" %)**Step1 :**(%%)** Clean probe**
565 +
566 +user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks new, users can clean it to remove hydrochloric acid or other liquids from the surface.
567 +
568 +(% style="color:blue" %)**Step2 :**(%%)** Immerse the sensor in ph buffer solution to make the sensor values stable**
569 +
568 568  (((
569 569  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
572 +
573 +(% style="color:red" %)**Note:Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer**
574 +
575 +
576 +(% style="color:blue" %)**Step3 :**(%%)** The numerically stable sensors were calibrated using commands**
570 570  )))
571 571  
572 572  (((
573 -After stable, user can use below command to calibrate.
580 + User can use below command to calibrate.
574 574  
575 575  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:520px" %)
576 576  |(% style="background-color:#d9e2f3; color:#0070c0; width:120px" %)**pH buffer solution**|(% style="background-color:#d9e2f3; color:#0070c0; width:150px" %)**AT Command to calibrate**|(% style="background-color:#d9e2f3; color:#0070c0; width:150px" %)**Downlink Command**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**Read Cal Value**
... ... @@ -598,7 +598,19 @@
598 598  )))
599 599  )))
600 600  
608 +To use the AT COMMAND, refer to this link:
601 601  
610 +* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
611 +
612 +* AT Command via UART Connection : See [[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
613 +
614 +To use Downlink, take TTN as an example, please refer to this link:
615 +
616 +* LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
617 +
618 +When the command is successfully used, the node sends a uplink.
619 +This is the payload for uplink
620 +
602 602  (% style="color:#037691" %)**Calibration Payload**
603 603  
604 604  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
... ... @@ -624,8 +624,13 @@
624 624  
625 625  * Reply to non-confirmed packet: 14 00
626 626  
646 +(% style="color:blue" %)**Step4:**(%%)**After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration.**
627 627  
648 +Examples:
649 +After using the command AT+PH=9 in 9.18ph buffer
650 +The readout returned by the sensor in 9.18ph buffer should be pH=9
628 628  
652 +
629 629  == 2.8 Frequency Plans ==
630 630  
631 631  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0