... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -54,8 +54,6 @@
54 54  * Downlink to change configure
55 55  * 8500mAh Battery for long term use
56 56  
57 -
58 -
59 59  == 1.3 Specification ==
60 60  
61 61  
... ... @@ -101,8 +101,6 @@
101 101  * Sleep Mode: 5uA @ 3.3v
102 102  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
103 103  
104 -
105 -
106 106  == 1.4 Applications ==
107 107  
108 108  
... ... @@ -135,8 +135,6 @@
135 135  )))
136 136  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
137 137  
138 -
139 -
140 140  == 1.7 BLE connection ==
141 141  
142 142  
... ... @@ -337,8 +337,6 @@
337 337  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
338 338  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
339 339  
340 -
341 -
342 342  === 2.3.7 Decode payload in The Things Network ===
343 343  
344 344  
... ... @@ -564,13 +564,23 @@
564 564  
565 565  == 2.7 Calibration ==
566 566  
559 +Step1 : Clean probe
567 567  
561 +user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks new, users can clean it to remove hydrochloric acid or other liquids from the surface.
562 +
563 +Step2 : Immerse the sensor in ph buffer solution to make the sensor values stable
564 +
568 568  (((
569 569  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
567 +
568 +Note:Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer
569 +
570 +
571 +Step3 : The numerically stable sensors were calibrated using commands
570 570  )))
571 571  
572 572  (((
573 -After stable, user can use below command to calibrate.
575 + User can use below command to calibrate.
574 574  
575 575  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:520px" %)
576 576  |(% style="background-color:#d9e2f3; color:#0070c0; width:120px" %)**pH buffer solution**|(% style="background-color:#d9e2f3; color:#0070c0; width:150px" %)**AT Command to calibrate**|(% style="background-color:#d9e2f3; color:#0070c0; width:150px" %)**Downlink Command**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**Read Cal Value**
... ... @@ -598,7 +598,20 @@
598 598  )))
599 599  )))
600 600  
603 +To use the AT COMMAND, refer to this link:
601 601  
605 +* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
606 +
607 +* AT Command via UART Connection : See [[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
608 +
609 +To use Downlink, take TTN as an example, please refer to this link:
610 +
611 +* LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
612 +
613 +
614 +When the command is successfully used, the node sends a uplink.
615 +This is the payload for uplink
616 +
602 602  (% style="color:#037691" %)**Calibration Payload**
603 603  
604 604  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
... ... @@ -624,8 +624,15 @@
624 624  
625 625  * Reply to non-confirmed packet: 14 00
626 626  
642 +Step4:
627 627  
644 +After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration
628 628  
646 +Examples:
647 +After using the command AT+PH=9 in 9.18ph buffer
648 +The readout returned by the sensor in 9.18ph buffer should be pH=9
649 +
650 +
629 629  == 2.8 Frequency Plans ==
630 630  
631 631  
... ... @@ -647,8 +647,6 @@
647 647  
648 648  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
649 649  
650 -
651 -
652 652  == 3.2 General Commands ==
653 653  
654 654  
... ... @@ -749,8 +749,6 @@
749 749  
750 750  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
751 751  
752 -
753 -
754 754  === 3.3.3 Calibrate Sensor ===
755 755  
756 756  
... ... @@ -861,8 +861,6 @@
861 861  
862 862  * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
863 863  
864 -
865 -
866 866  = 6. FAQ =
867 867  
868 868  == 6.1  AT Commands input doesn't work ==
... ... @@ -894,8 +894,6 @@
894 894  
895 895  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
896 896  
897 -
898 -
899 899  = 8. ​Packing Info =
900 900  
901 901  
... ... @@ -913,8 +913,6 @@
913 913  
914 914  * Weight / pcs : g
915 915  
916 -
917 -
918 918  = 9. Support =
919 919  
920 920  