... ... @@ -332,6 +332,7 @@
332 332  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
333 333  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
334 334  
335 +
335 335  === 2.3.7 Decode payload in The Things Network ===
336 336  
337 337  
... ... @@ -435,16 +435,18 @@
435 435  === 2.6.1 Before measurement ===
436 436  
437 437  
439 +
438 438  (((
439 439  If the SPH01-LB has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
440 440  )))
441 441  
442 442  
445 +
443 443  === 2.6.2 Measurement ===
444 444  
445 445  
446 446  (((
447 -(% style="color:blue" %)**Measurement the soil surface:**
450 +(% style="color:#4f81bd" %)**Measurement the soil surface:**
448 448  )))
449 449  
450 450  (((
... ... @@ -471,7 +471,7 @@
471 471  
472 472  
473 473  (((
474 -(% style="color:blue" %)**Measurement inside soil:**
477 +(% style="color:#4f81bd" %)**Measurement inside soil:**
475 475  )))
476 476  
477 477  (((
... ... @@ -486,30 +486,23 @@
486 486  === 2.6.3 Maintain Probe ===
487 487  
488 488  
489 -(((
490 -~1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
492 +1. (((
493 +pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
491 491  )))
492 -
493 -(((
494 -2. After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
495 +1. (((
496 +After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
495 495  )))
496 -
497 -(((
498 -3. Probe reference electrode is also no strong, need to avoid strong force or hitting.
498 +1. (((
499 +Probe reference electrode is also no strong, need to avoid strong force or hitting.
499 499  )))
500 -
501 -(((
502 -4. User should keep reference electrode wet while not use.
501 +1. (((
502 +User should keep reference electrode wet while not use.
503 503  )))
504 -
505 -(((
506 -5. Avoid the probes to touch oily matter. Which will cause issue in accuracy.
504 +1. (((
505 +Avoid the probes to touch oily matter. Which will cause issue in accuracy.
507 507  )))
508 -
509 -(((
510 -6. The probe is IP68 can be put in water.
511 -
512 -
507 +1. (((
508 +The probe is IP68 can be put in water.
513 513  )))
514 514  
515 515  == 2.7 Calibration ==
... ... @@ -571,9 +571,9 @@
571 571  |(% style="width:183px" %)Get Calibration Version Info|(% style="width:55px" %)Any|(% style="width:93px" %)14|(% style="width:146px" %)2
572 572  
573 573  * Reply to the confirmation package: 14 01
574 -
575 575  * Reply to non-confirmed packet: 14 00
576 576  
572 +
577 577  == 2.8 Frequency Plans ==
578 578  
579 579  
... ... @@ -582,6 +582,7 @@
582 582  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
583 583  
584 584  
581 +
585 585  = 3. Configure SPH01-LB =
586 586  
587 587  == 3.1 Configure Methods ==
... ... @@ -658,6 +658,7 @@
658 658  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
659 659  )))
660 660  
658 +
661 661  === 3.3.2 Set Interrupt Mode ===
662 662  
663 663  
... ... @@ -693,6 +693,7 @@
693 693  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
694 694  
695 695  
694 +
696 696  === 3.3.3 Calibrate Sensor ===
697 697  
698 698  
... ... @@ -711,7 +711,6 @@
711 711  |(% style="width:193px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:149px" %)2
712 712  
713 713  * Reply to the confirmation package: 26 01
714 -
715 715  * Reply to non-confirmed packet: 26 00
716 716  
717 717  Device will send an uplink after got this downlink command. With below payload:
... ... @@ -839,6 +839,7 @@
839 839  
840 840  
841 841  
840 +
842 842  = 8. ​Packing Info =
843 843  
844 844  
... ... @@ -858,6 +858,7 @@
858 858  
859 859  
860 860  
860 +
861 861  = 9. Support =
862 862  
863 863  