Changes for page SPH01-LB -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2024/01/15 09:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -332,7 +332,6 @@ 332 332 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 333 333 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 334 334 335 - 336 336 === 2.3.7 Decode payload in The Things Network === 337 337 338 338 ... ... @@ -436,18 +436,16 @@ 436 436 === 2.6.1 Before measurement === 437 437 438 438 439 - 440 440 ((( 441 441 If the SPH01-LB has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 442 442 ))) 443 443 444 444 445 - 446 446 === 2.6.2 Measurement === 447 447 448 448 449 449 ((( 450 -(% style="color: #blue" %)**Measurement the soil surface:**447 +(% style="color:blue" %)**Measurement the soil surface:** 451 451 ))) 452 452 453 453 ((( ... ... @@ -489,23 +489,30 @@ 489 489 === 2.6.3 Maintain Probe === 490 490 491 491 492 - 1.(((493 -pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 489 +((( 490 +~1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 494 494 ))) 495 -1. ((( 496 -After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 492 + 493 +((( 494 +2. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 497 497 ))) 498 -1. ((( 499 -Probe reference electrode is also no strong, need to avoid strong force or hitting. 496 + 497 +((( 498 +3. Probe reference electrode is also no strong, need to avoid strong force or hitting. 500 500 ))) 501 -1. ((( 502 -User should keep reference electrode wet while not use. 500 + 501 +((( 502 +4. User should keep reference electrode wet while not use. 503 503 ))) 504 -1. ((( 505 -Avoid the probes to touch oily matter. Which will cause issue in accuracy. 504 + 505 +((( 506 +5. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 506 506 ))) 507 -1. ((( 508 -The probe is IP68 can be put in water. 508 + 509 +((( 510 +6. The probe is IP68 can be put in water. 511 + 512 + 509 509 ))) 510 510 511 511 == 2.7 Calibration == ... ... @@ -567,9 +567,9 @@ 567 567 |(% style="width:183px" %)Get Calibration Version Info|(% style="width:55px" %)Any|(% style="width:93px" %)14|(% style="width:146px" %)2 568 568 569 569 * Reply to the confirmation package: 14 01 574 + 570 570 * Reply to non-confirmed packet: 14 00 571 571 572 - 573 573 == 2.8 Frequency Plans == 574 574 575 575 ... ... @@ -578,7 +578,6 @@ 578 578 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 579 579 580 580 581 - 582 582 = 3. Configure SPH01-LB = 583 583 584 584 == 3.1 Configure Methods == ... ... @@ -655,7 +655,6 @@ 655 655 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 656 656 ))) 657 657 658 - 659 659 === 3.3.2 Set Interrupt Mode === 660 660 661 661 ... ... @@ -691,7 +691,6 @@ 691 691 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 692 692 693 693 694 - 695 695 === 3.3.3 Calibrate Sensor === 696 696 697 697 ... ... @@ -710,6 +710,7 @@ 710 710 |(% style="width:193px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:149px" %)2 711 711 712 712 * Reply to the confirmation package: 26 01 714 + 713 713 * Reply to non-confirmed packet: 26 00 714 714 715 715 Device will send an uplink after got this downlink command. With below payload: ... ... @@ -837,7 +837,6 @@ 837 837 838 838 839 839 840 - 841 841 = 8. Packing Info = 842 842 843 843 ... ... @@ -857,7 +857,6 @@ 857 857 858 858 859 859 860 - 861 861 = 9. Support = 862 862 863 863