... ... @@ -332,8 +332,6 @@
332 332  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
333 333  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
334 334  
335 -
336 -
337 337  === 2.3.7 Decode payload in The Things Network ===
338 338  
339 339  
... ... @@ -437,22 +437,20 @@
437 437  === 2.6.1 Before measurement ===
438 438  
439 439  
440 -
441 441  (((
442 442  If the SPH01-LB has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
443 443  )))
444 444  
445 445  
446 -
447 447  === 2.6.2 Measurement ===
448 448  
449 449  
450 450  (((
451 -(% style="color:#4f81bd" %)**Measurement the soil surface:**
447 +(% style="color:blue" %)**Measurement the soil surface:**
452 452  )))
453 453  
454 454  (((
455 -[[image:1654592946732-634.png]]
451 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654592946732-634.png?rev=1.1||alt="1654592946732-634.png"]]
456 456  
457 457  
458 458  )))
... ... @@ -475,7 +475,7 @@
475 475  
476 476  
477 477  (((
478 -(% style="color:#4f81bd" %)**Measurement inside soil:**
474 +(% style="color:blue" %)**Measurement inside soil:**
479 479  )))
480 480  
481 481  (((
... ... @@ -490,26 +490,32 @@
490 490  === 2.6.3 Maintain Probe ===
491 491  
492 492  
493 -1. (((
494 -pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
489 +(((
490 +~1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
495 495  )))
496 -1. (((
497 -After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
492 +
493 +(((
494 +2. After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
498 498  )))
499 -1. (((
500 -Probe reference electrode is also no strong, need to avoid strong force or hitting.
496 +
497 +(((
498 +3. Probe reference electrode is also no strong, need to avoid strong force or hitting.
501 501  )))
502 -1. (((
503 -User should keep reference electrode wet while not use.
500 +
501 +(((
502 +4. User should keep reference electrode wet while not use.
504 504  )))
505 -1. (((
506 -Avoid the probes to touch oily matter. Which will cause issue in accuracy.
504 +
505 +(((
506 +5. Avoid the probes to touch oily matter. Which will cause issue in accuracy.
507 507  )))
508 -1. (((
509 -The probe is IP68 can be put in water.
510 -)))
511 511  
509 +(((
510 +6. The probe is IP68 can be put in water.
512 512  
512 +
513 +)))
514 +
513 513  == 2.7 Calibration ==
514 514  
515 515  
... ... @@ -569,10 +569,9 @@
569 569  |(% style="width:183px" %)Get Calibration Version Info|(% style="width:55px" %)Any|(% style="width:93px" %)14|(% style="width:146px" %)2
570 570  
571 571  * Reply to the confirmation package: 14 01
574 +
572 572  * Reply to non-confirmed packet: 14 00
573 573  
574 -
575 -
576 576  == 2.8 Frequency Plans ==
577 577  
578 578  
... ... @@ -581,7 +581,6 @@
581 581  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
582 582  
583 583  
584 -
585 585  = 3. Configure SPH01-LB =
586 586  
587 587  == 3.1 Configure Methods ==
... ... @@ -658,8 +658,6 @@
658 658  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
659 659  )))
660 660  
661 -
662 -
663 663  === 3.3.2 Set Interrupt Mode ===
664 664  
665 665  
... ... @@ -695,8 +695,6 @@
695 695  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
696 696  
697 697  
698 -
699 -
700 700  === 3.3.3 Calibrate Sensor ===
701 701  
702 702  
... ... @@ -715,6 +715,7 @@
715 715  |(% style="width:193px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:149px" %)2
716 716  
717 717  * Reply to the confirmation package: 26 01
714 +
718 718  * Reply to non-confirmed packet: 26 00
719 719  
720 720  Device will send an uplink after got this downlink command. With below payload:
... ... @@ -842,8 +842,6 @@
842 842  
843 843  
844 844  
845 -
846 -
847 847  = 8. ​Packing Info =
848 848  
849 849  
... ... @@ -863,8 +863,6 @@
863 863  
864 864  
865 865  
866 -
867 -
868 868  = 9. Support =
869 869  
870 870  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0