Changes for page SPH01-LB -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2024/01/15 09:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,6 +54,8 @@ 54 54 * Downlink to change configure 55 55 * 8500mAh Battery for long term use 56 56 57 + 58 + 57 57 == 1.3 Specification == 58 58 59 59 ... ... @@ -99,11 +99,15 @@ 99 99 * Sleep Mode: 5uA @ 3.3v 100 100 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 101 101 104 + 105 + 102 102 == 1.4 Applications == 103 103 104 104 105 105 * Smart Agriculture 106 106 111 + 112 + 107 107 == 1.5 Sleep mode and working mode == 108 108 109 109 ... ... @@ -131,6 +131,8 @@ 131 131 ))) 132 132 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 133 133 140 + 141 + 134 134 == 1.7 BLE connection == 135 135 136 136 ... ... @@ -437,24 +437,20 @@ 437 437 === 2.6.1 Before measurement === 438 438 439 439 440 - 441 441 ((( 442 442 If the SPH01-LB has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 443 443 ))) 444 444 445 445 446 - 447 447 === 2.6.2 Measurement === 448 448 449 449 450 450 ((( 451 -(% style="color: #4f81bd" %)**Measurement the soil surface:**457 +(% style="color:blue" %)**Measurement the soil surface:** 452 452 ))) 453 453 454 454 ((( 455 -[[image:1654592946732-634.png]] 456 - 457 - 461 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654592946732-634.png?rev=1.1||alt="1654592946732-634.png"]] 458 458 ))) 459 459 460 460 ((( ... ... @@ -475,7 +475,7 @@ 475 475 476 476 477 477 ((( 478 -(% style="color: #4f81bd" %)**Measurement inside soil:**482 +(% style="color:blue" %)**Measurement inside soil:** 479 479 ))) 480 480 481 481 ((( ... ... @@ -490,26 +490,32 @@ 490 490 === 2.6.3 Maintain Probe === 491 491 492 492 493 - 1.(((494 -pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 497 +((( 498 +~1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 495 495 ))) 496 -1. ((( 497 -After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 500 + 501 +((( 502 +2. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 498 498 ))) 499 -1. ((( 500 -Probe reference electrode is also no strong, need to avoid strong force or hitting. 504 + 505 +((( 506 +3. Probe reference electrode is also no strong, need to avoid strong force or hitting. 501 501 ))) 502 -1. ((( 503 -User should keep reference electrode wet while not use. 508 + 509 +((( 510 +4. User should keep reference electrode wet while not use. 504 504 ))) 505 -1. ((( 506 -Avoid the probes to touch oily matter. Which will cause issue in accuracy. 512 + 513 +((( 514 +5. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 507 507 ))) 508 -1. ((( 509 -The probe is IP68 can be put in water. 510 -))) 511 511 517 +((( 518 +6. The probe is IP68 can be put in water. 512 512 520 + 521 +))) 522 + 513 513 == 2.7 Calibration == 514 514 515 515 ... ... @@ -569,6 +569,7 @@ 569 569 |(% style="width:183px" %)Get Calibration Version Info|(% style="width:55px" %)Any|(% style="width:93px" %)14|(% style="width:146px" %)2 570 570 571 571 * Reply to the confirmation package: 14 01 582 + 572 572 * Reply to non-confirmed packet: 14 00 573 573 574 574 ... ... @@ -581,7 +581,6 @@ 581 581 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 582 582 583 583 584 - 585 585 = 3. Configure SPH01-LB = 586 586 587 587 == 3.1 Configure Methods == ... ... @@ -595,6 +595,8 @@ 595 595 596 596 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 597 597 608 + 609 + 598 598 == 3.2 General Commands == 599 599 600 600 ... ... @@ -656,9 +656,10 @@ 656 656 657 657 * ((( 658 658 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 659 -))) 660 660 661 661 673 + 674 +))) 662 662 663 663 === 3.3.2 Set Interrupt Mode === 664 664 ... ... @@ -696,7 +696,6 @@ 696 696 697 697 698 698 699 - 700 700 === 3.3.3 Calibrate Sensor === 701 701 702 702 ... ... @@ -715,6 +715,7 @@ 715 715 |(% style="width:193px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:149px" %)2 716 716 717 717 * Reply to the confirmation package: 26 01 730 + 718 718 * Reply to non-confirmed packet: 26 00 719 719 720 720 Device will send an uplink after got this downlink command. With below payload: ... ... @@ -780,7 +780,6 @@ 780 780 0x07: LDDS12 781 781 782 782 783 - 784 784 = 4. Battery & Power Consumption = 785 785 786 786 ... ... @@ -809,6 +809,8 @@ 809 809 810 810 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 811 811 824 + 825 + 812 812 = 6. FAQ = 813 813 814 814 == 6.1 AT Commands input doesn't work == ... ... @@ -841,9 +841,6 @@ 841 841 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 842 842 843 843 844 - 845 - 846 - 847 847 = 8. Packing Info = 848 848 849 849 ... ... @@ -863,8 +863,6 @@ 863 863 864 864 865 865 866 - 867 - 868 868 = 9. Support = 869 869 870 870