Changes for page SPH01-LB -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2024/01/15 09:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -258,7 +258,7 @@ 258 258 === 2.3.1 Battery Info === 259 259 260 260 261 -Check the battery voltage for LSPH01.261 +Check the battery voltage for SPH01-LB. 262 262 263 263 Ex1: 0x0B45 = 2885mV 264 264 ... ... @@ -332,8 +332,6 @@ 332 332 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 333 333 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 334 334 335 - 336 - 337 337 === 2.3.7 Decode payload in The Things Network === 338 338 339 339 ... ... @@ -352,7 +352,7 @@ 352 352 == 2.4 Uplink Interval == 353 353 354 354 355 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]353 +The SPH01-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 356 356 357 357 358 358 == 2.5 Datalog Feature == ... ... @@ -437,22 +437,20 @@ 437 437 === 2.6.1 Before measurement === 438 438 439 439 440 - 441 441 ((( 442 -If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy.439 +If the SPH01-LB has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 443 443 ))) 444 444 445 445 446 - 447 447 === 2.6.2 Measurement === 448 448 449 449 450 450 ((( 451 -(% style="color: #4f81bd" %)**Measurement the soil surface:**447 +(% style="color:blue" %)**Measurement the soil surface:** 452 452 ))) 453 453 454 454 ((( 455 -[[image:1654592946732-634.png]] 451 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654592946732-634.png?rev=1.1||alt="1654592946732-634.png"]] 456 456 457 457 458 458 ))) ... ... @@ -475,7 +475,7 @@ 475 475 476 476 477 477 ((( 478 -(% style="color: #4f81bd" %)**Measurement inside soil:**474 +(% style="color:blue" %)**Measurement inside soil:** 479 479 ))) 480 480 481 481 ((( ... ... @@ -490,26 +490,32 @@ 490 490 === 2.6.3 Maintain Probe === 491 491 492 492 493 - 1.(((494 -pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 489 +((( 490 +~1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 495 495 ))) 496 -1. ((( 497 -After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 492 + 493 +((( 494 +2. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 498 498 ))) 499 -1. ((( 500 -Probe reference electrode is also no strong, need to avoid strong force or hitting. 496 + 497 +((( 498 +3. Probe reference electrode is also no strong, need to avoid strong force or hitting. 501 501 ))) 502 -1. ((( 503 -User should keep reference electrode wet while not use. 500 + 501 +((( 502 +4. User should keep reference electrode wet while not use. 504 504 ))) 505 -1. ((( 506 -Avoid the probes to touch oily matter. Which will cause issue in accuracy. 504 + 505 +((( 506 +5. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 507 507 ))) 508 -1. ((( 509 -The probe is IP68 can be put in water. 510 -))) 511 511 509 +((( 510 +6. The probe is IP68 can be put in water. 512 512 512 + 513 +))) 514 + 513 513 == 2.7 Calibration == 514 514 515 515 ... ... @@ -569,10 +569,9 @@ 569 569 |(% style="width:183px" %)Get Calibration Version Info|(% style="width:55px" %)Any|(% style="width:93px" %)14|(% style="width:146px" %)2 570 570 571 571 * Reply to the confirmation package: 14 01 574 + 572 572 * Reply to non-confirmed packet: 14 00 573 573 574 - 575 - 576 576 == 2.8 Frequency Plans == 577 577 578 578 ... ... @@ -581,7 +581,6 @@ 581 581 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 582 582 583 583 584 - 585 585 = 3. Configure SPH01-LB = 586 586 587 587 == 3.1 Configure Methods == ... ... @@ -658,8 +658,6 @@ 658 658 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 659 659 ))) 660 660 661 - 662 - 663 663 === 3.3.2 Set Interrupt Mode === 664 664 665 665 ... ... @@ -695,8 +695,6 @@ 695 695 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 696 696 697 697 698 - 699 - 700 700 === 3.3.3 Calibrate Sensor === 701 701 702 702 ... ... @@ -715,6 +715,7 @@ 715 715 |(% style="width:193px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:149px" %)2 716 716 717 717 * Reply to the confirmation package: 26 01 714 + 718 718 * Reply to non-confirmed packet: 26 00 719 719 720 720 Device will send an uplink after got this downlink command. With below payload: ... ... @@ -734,7 +734,7 @@ 734 734 Always 0x02 735 735 ))) 736 736 737 -(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01734 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for SPH01-LB 738 738 739 739 (% style="color:#037691" %)**Frequency Band**: 740 740 ... ... @@ -840,6 +840,8 @@ 840 840 841 841 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 842 842 840 + 841 + 843 843 = 8. Packing Info = 844 844 845 845 ... ... @@ -857,6 +857,8 @@ 857 857 858 858 * Weight / pcs : g 859 859 859 + 860 + 860 860 = 9. Support = 861 861 862 862