... ... @@ -581,6 +581,7 @@
581 581  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
582 582  
583 583  
584 +
584 584  = 3. Configure SPH01-LB =
585 585  
586 586  == 3.1 Configure Methods ==
... ... @@ -655,285 +655,131 @@
655 655  
656 656  * (((
657 657  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
658 -
659 -
660 -
661 661  )))
662 662  
663 -=== 3.3.2 Quit AT Command ===
664 664  
665 665  
666 -Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
663 +=== 3.3.2 Set Interrupt Mode ===
667 667  
668 -(% style="color:blue" %)**AT Command: AT+DISAT**
669 669  
670 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %)
671 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response**
672 -|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK
666 +Feature, Set Interrupt mode for PA8 of pin.
673 673  
674 -(% style="color:blue" %)**Downlink Command:**
668 +When AT+INTMOD=0 is set, PA8 is used as a digital input port.
675 675  
676 -No downlink command for this feature.
670 +(% style="color:blue" %)**AT Command: AT+INTMOD**
677 677  
678 -
679 -=== 3.3.3 Get Device Status ===
680 -
681 -
682 -Send a LoRaWAN downlink to ask device send Alarm settings.
683 -
684 -(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
685 -
686 -Sensor will upload Device Status via FPORT=5. See payload section for detail.
687 -
688 -
689 -=== 3.3.4 Enable / Disable Alarm ===
690 -
691 -
692 -Feature: Enable/Disable Alarm for open/close event. Default value 0.
693 -
694 -(% style="color:blue" %)**AT Command:**
695 -
696 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
697 -|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response**
698 -|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK
699 -|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK
700 -
701 -(% style="color:blue" %)**Downlink Command:**
702 -
703 -**0xA7 01**  ~/~/  Same As AT+DISALARM=1
704 -
705 -**0xA7 00    ** ~/~/  Same As AT+DISALARM=0
706 -
707 -
708 -=== 3.3.5 Alarm Base on Timeout ===
709 -
710 -
711 -(((
712 -CPL03-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
672 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
673 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
674 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
675 +0
676 +OK
677 +the mode is 0 =Disable Interrupt
713 713  )))
679 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
680 +Set Transmit Interval
681 +0. (Disable Interrupt),
682 +~1. (Trigger by rising and falling edge)
683 +2. (Trigger by falling edge)
684 +3. (Trigger by rising edge)
685 +)))|(% style="width:157px" %)OK
714 714  
687 +(% style="color:blue" %)**Downlink Command: 0x06**
715 715  
716 -(((
717 -(% style="color:#4f81bd" %)**1. Keep Status: Status to be monitor**
718 -)))
689 +Format: Command Code (0x06) followed by 3 bytes.
719 719  
720 -(((
721 -**Keep Status = 1**: Monitor Close to Open event
722 -)))
691 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
723 723  
724 -(((
725 -**Keep Status = 0**: Monitor Open to Close event
726 -)))
693 +* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
727 727  
695 +* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
728 728  
729 -(((
730 -(% style="color:#4f81bd" %)**2. Keep Time: Timeout to send an Alarm**
731 -)))
732 732  
733 -(((
734 -Range 0 ~~ 65535(0xFFFF) seconds.
735 -)))
736 736  
737 -(((
738 -If** keep time = 0**, Disable Alarm Base on Timeout feature.
739 -)))
740 740  
741 -(((
742 -If **keep time > 0**, device will monitor the keep status event and send an alarm when status doesn’t change after timeout.
743 -)))
700 +=== 3.3.3 Calibrate Sensor ===
744 744  
745 745  
746 -(((
747 -(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
748 -)))
703 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
749 749  
750 -(((
751 -(% style="color:blue" %)**AT+TTRIG=1,30**(%%)  ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL03-LB will send an uplink packet, the [[Alarm bit>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
752 -)))
753 753  
754 -(((
755 -(% style="color:blue" %)**AT+TTIG=0,0 **(%%) ~-~-> Default Value, disable timeout Alarm.
756 -)))
706 +=== 3.3.4 Get Firmware Version Info ===
757 757  
758 758  
759 -(((
760 -(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure:
761 -)))
709 +Feature: use downlink to get firmware version.
762 762  
763 -(((
764 -**Command: 0xA9 aa bb cc**
765 -)))
711 +(% style="color:#037691" %)**Downlink Command: 0x26**
766 766  
767 -(((
768 -**A9: **Command Type Code
769 -)))
770 -
771 -(((
772 -**aa: **status to be monitored
773 -)))
774 -
775 -(((
776 -**bb cc: **timeout.
777 -)))
778 -
779 -
780 -(((
781 -If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30
782 -)))
783 -
784 -(((
785 -Or
786 -)))
787 -
788 -(((
789 -0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm.
790 -)))
791 -
792 -
793 -=== 3.3.6 Clear Flash Record ===
794 -
795 -
796 -Feature: Clear flash storage for data log feature.
797 -
798 -(% style="color:blue" %)**AT Command: AT+CLRDTA**
799 -
800 800  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
801 -|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response**
802 -|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK
714 +|(% style="background-color:#d9e2f3; color:#0070c0; width:193px" %)**Downlink Control Type**|(% style="background-color:#d9e2f3; color:#0070c0; width:57px" %)**FPort**|(% style="background-color:#d9e2f3; color:#0070c0; width:91px" %)**Type Code**|(% style="background-color:#d9e2f3; color:#0070c0; width:159px" %)**Downlink payload size(bytes)**
715 +|(% style="width:193px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:149px" %)2
803 803  
804 -(((
805 -(% style="color:blue" %)**Downlink Command:**
806 -)))
717 +* Reply to the confirmation package: 26 01
718 +* Reply to non-confirmed packet: 26 00
807 807  
808 -(((
809 -* **Example**: 0xA301  ~/~/  Same as AT+CLRDTA
810 -)))
720 +Device will send an uplink after got this downlink command. With below payload:
811 811  
722 +Configures info payload:
812 812  
813 -
814 -=== 3.3.7 Set trigger mode ===
815 -
816 -
817 -Feature: Set the trigger interrupt mode.
818 -
819 -(% style="color:blue" %)**AT Command: AT+TTRMOD**
820 -
821 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %)
822 -|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response**
823 -|(% style="width:157px" %)(((
824 -AT+TTRMOD=1
825 -)))|(% style="width:156px" %)Count and trigger from open to close (rising edge)|(% style="width:89px" %)(((
826 -(((
827 -OK
724 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
725 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**5**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**1**
726 +|Value|Software Type|(((
727 +Frequency
728 +Band
729 +)))|Sub-band|(((
730 +Firmware
731 +Version
732 +)))|Sensor Type|Reserve|(((
733 +[[Message Type>>||anchor="H2.3.6MessageType"]]
734 +Always 0x02
828 828  )))
829 -)))
830 -|(% style="width:157px" %)(((
831 -AT+TTRMOD=0
832 -)))|(% style="width:156px" %)Count and trigger from close to open (falling edge)|(% style="width:89px" %)(((
833 -OK
834 -)))
835 835  
836 -(% style="color:blue" %)**Downlink Command:**
737 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
837 837  
838 -* **Example**: 0xA401  ~/~/  Same as AT+ TTRMOD =1
739 +(% style="color:#037691" %)**Frequency Band**:
839 839  
840 -=== 3.3.8 Set the calculate flag ===
741 +*0x01: EU868
841 841  
743 +*0x02: US915
842 842  
843 -Feature: Set the calculate flag
745 +*0x03: IN865
844 844  
845 -(% style="color:blue" %)**AT Command: AT+CALCFLAG**
747 +*0x04: AU915
846 846  
847 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
848 -|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
849 -|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
850 -|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
749 +*0x05: KZ865
851 851  
852 -(% style="color:blue" %)**Downlink Command:**
751 +*0x06: RU864
853 853  
854 -* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
753 +*0x07: AS923
855 855  
856 -=== 3.3.9 Set count number ===
755 +*0x08: AS923-1
857 857  
757 +*0x09: AS923-2
858 858  
859 -Feature: Manually set the count number
759 +*0xa0: AS923-3
860 860  
861 -(% style="color:blue" %)**AT Command: AT+SETCNT**
862 862  
863 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
864 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
865 -|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
866 -|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
762 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
867 867  
868 -(% style="color:blue" %)**Downlink Command:**
764 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
869 869  
870 -* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
766 +(% style="color:#037691" %)**Sensor Type**:
871 871  
872 -* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
768 +0x01: LSE01
873 873  
874 -=== 3.3.10 Set Interrupt Mode ===
770 +0x02: LDDS75
875 875  
772 +0x03: LDDS20
876 876  
877 -Feature, Set Interrupt mode for PA8 of pin.
774 +0x04: LLMS01
878 878  
879 -When AT+INTMOD=0 is set, PA8 is used as a digital input port.
776 +0x05: LSPH01
880 880  
881 -(% style="color:blue" %)**AT Command: AT+INTMOD**
778 +0x06: LSNPK01
882 882  
883 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
884 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
885 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
886 -0
887 -OK
888 -the mode is 0 =Disable Interrupt
889 -)))
890 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
891 -Set Transmit Interval
892 -0. (Disable Interrupt),
893 -~1. (Trigger by rising and falling edge)
894 -2. (Trigger by falling edge)
895 -3. (Trigger by rising edge)
896 -)))|(% style="width:157px" %)OK
780 +0x07: LDDS12
897 897  
898 -(% style="color:blue" %)**Downlink Command: 0x06**
899 899  
900 -Format: Command Code (0x06) followed by 3 bytes.
901 901  
902 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
903 -
904 -* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
905 -
906 -* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
907 -
908 -=== 3.3.11 Set Power Output Duration ===
909 -
910 -
911 -Control the output duration 5V . Before each sampling, device will
912 -
913 -~1. first enable the power output to external sensor,
914 -
915 -2. keep it on as per duration, read sensor value and construct uplink payload
916 -
917 -3. final, close the power output.
918 -
919 -(% style="color:blue" %)**AT Command: AT+5VT**
920 -
921 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
922 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
923 -|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default)
924 -OK
925 -|(% style="width:154px" %)AT+5VT=500|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK
926 -
927 -(% style="color:blue" %)**Downlink Command: 0x07**
928 -
929 -Format: Command Code (0x07) followed by 2 bytes.
930 -
931 -The first and second bytes are the time to turn on.
932 -
933 -* Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
934 -
935 -* Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
936 -
937 937  = 4. Battery & Power Consumption =
938 938  
939 939  