<
From version < 64.11 >
edited by Xiaoling
on 2023/05/30 15:30
To version < 64.8 >
edited by Xiaoling
on 2023/05/30 11:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -53,7 +53,6 @@
53 53  * Downlink to change configure
54 54  * 8500mAh Battery for long term use
55 55  
56 -
57 57  == 1.3 Specification ==
58 58  
59 59  
... ... @@ -82,7 +82,6 @@
82 82  * Sleep Mode: 5uA @ 3.3v
83 83  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
84 84  
85 -
86 86  == 1.4 Applications ==
87 87  
88 88  
... ... @@ -90,7 +90,6 @@
90 90  * Pulse meter application
91 91  * Dry Contact Detection
92 92  
93 -
94 94  == 1.5 Sleep mode and working mode ==
95 95  
96 96  
... ... @@ -118,7 +118,6 @@
118 118  )))
119 119  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
120 120  
121 -
122 122  == 1.7 BLE connection ==
123 123  
124 124  
... ... @@ -547,7 +547,7 @@
547 547  
548 548  
549 549  (((
550 -CPL03-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
546 +CPL03-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.4DatalogFeature"]].
551 551  )))
552 552  
553 553  (((
... ... @@ -716,6 +716,7 @@
716 716  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
717 717  
718 718  
715 +
719 719  === 2.5.4 Poll sensor value ===
720 720  
721 721  
... ... @@ -743,7 +743,7 @@
743 743  )))
744 744  
745 745  
746 -== 2.6 Frequency Plans ==
743 +== 2.7 Frequency Plans ==
747 747  
748 748  
749 749  The CPL03-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
... ... @@ -762,7 +762,6 @@
762 762  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
763 763  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
764 764  
765 -
766 766  == 3.2 General Commands ==
767 767  
768 768  
... ... @@ -978,6 +978,7 @@
978 978  
979 979  
980 980  
977 +
981 981  === 3.3.7 Set trigger mode ===
982 982  
983 983  
... ... @@ -1004,7 +1004,6 @@
1004 1004  
1005 1005  * **Example**: 0xA401  ~/~/  Same as AT+ TTRMOD =1
1006 1006  
1007 -
1008 1008  === 3.3.8 Set the calculate flag ===
1009 1009  
1010 1010  
... ... @@ -1021,7 +1021,6 @@
1021 1021  
1022 1022  * **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
1023 1023  
1024 -
1025 1025  === 3.3.9 Set count number ===
1026 1026  
1027 1027  
... ... @@ -1040,7 +1040,6 @@
1040 1040  
1041 1041  * **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
1042 1042  
1043 -
1044 1044  === 3.3.10 Set Interrupt Mode ===
1045 1045  
1046 1046  
... ... @@ -1075,7 +1075,6 @@
1075 1075  
1076 1076  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1077 1077  
1078 -
1079 1079  === 3.3.11 Set Power Output Duration ===
1080 1080  
1081 1081  
... ... @@ -1105,7 +1105,6 @@
1105 1105  
1106 1106  * Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
1107 1107  
1108 -
1109 1109  = 4. Battery & Power Consumption =
1110 1110  
1111 1111  
... ... @@ -1128,6 +1128,7 @@
1128 1128  
1129 1129  Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]**
1130 1130  
1123 +
1131 1131  Methods to Update Firmware:
1132 1132  
1133 1133  * (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
... ... @@ -1134,7 +1134,6 @@
1134 1134  
1135 1135  * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1136 1136  
1137 -
1138 1138  = 6. FAQ =
1139 1139  
1140 1140  == 6.1  AT Commands input doesn't work ==
... ... @@ -1166,7 +1166,6 @@
1166 1166  
1167 1167  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1168 1168  
1169 -
1170 1170  = 8. ​Packing Info =
1171 1171  
1172 1172  
... ... @@ -1184,7 +1184,6 @@
1184 1184  
1185 1185  * Weight / pcs : g
1186 1186  
1187 -
1188 1188  = 9. Support =
1189 1189  
1190 1190  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0