Changes for page SE01-LB/LS -- LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Edwin Chen on 2024/02/07 10:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -136,6 +136,7 @@ 136 136 137 137 [[image:image-20230523174230-1.png]] 138 138 139 +(% class="wikigeneratedid" %) 139 139 == == 140 140 141 141 == 1.8 Hardware Variant == ... ... @@ -143,9 +143,7 @@ 143 143 144 144 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 145 145 |=(% style="width: 102px;background-color:#D9E2F3;color:#0070C0" %)Model|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)Photo|=(% style="width: 218px;background-color:#D9E2F3;color:#0070C0" %)Probe Info 146 -|(% style="width:102px" %)((( 147 -S31-LB 148 -)))|(% style="width:190px" %)[[image:S31.jpg]]|(% style="width:297px" %)((( 147 +|(% style="width:102px" %)S31-LB|(% style="width:190px" %)[[image:S31.jpg]]|(% style="width:297px" %)((( 149 149 1 x SHT31 Probe 150 150 151 151 Cable Length : 2 meters ... ... @@ -152,9 +152,7 @@ 152 152 153 153 154 154 ))) 155 -|(% style="width:102px" %)((( 156 -S31B-LB 157 -)))|(% style="width:190px" %)[[image:S31B.jpg]]|(% style="width:297px" %)((( 154 +|(% style="width:102px" %)S31B-LB|(% style="width:190px" %)[[image:S31B.jpg]]|(% style="width:297px" %)((( 158 158 1 x SHT31 Probe 159 159 160 160 Installed in device. ... ... @@ -327,7 +327,7 @@ 327 327 [[Humidity>>||anchor="HHumidity"]] 328 328 ))) 329 329 330 -==== (% style="color:#4472c4" %)** 2.3.2.1Battery**(%%) ====327 +==== (% style="color:#4472c4" %)**Battery**(%%) ==== 331 331 332 332 Sensor Battery Level. 333 333 ... ... @@ -337,7 +337,7 @@ 337 337 338 338 339 339 340 -==== (% style="color:#4472c4" %)** 2.3.2.2Temperature**(%%) ====337 +==== (% style="color:#4472c4" %)**Temperature**(%%) ==== 341 341 342 342 **Example**: 343 343 ... ... @@ -348,13 +348,13 @@ 348 348 (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 349 349 350 350 351 -==== (% style="color:#4472c4" %)** 2.3.2.3Humidity**(%%) ====348 +==== (% style="color:#4472c4" %)**Humidity**(%%) ==== 352 352 353 353 354 354 Read:0x(0197)=412 Value: 412 / 10=41.2, So 41.2% 355 355 356 356 357 -==== (% style="color:#4472c4" %)** 2.3.2.4Alarm Flag& MOD**(%%) ====354 +==== (% style="color:#4472c4" %)**Alarm Flag& MOD**(%%) ==== 358 358 359 359 360 360 **Example:** ... ... @@ -389,12 +389,8 @@ 389 389 390 390 Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 391 391 392 -* ((( 393 -a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server. 394 -))) 395 -* ((( 396 -b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages. 397 -))) 389 +* a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server. 390 +* b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages. 398 398 399 399 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 400 400