From version < 40.3 >
edited by Xiaoling
on 2022/08/18 17:57
To version < 39.1 >
edited by Bei Jinggeng
on 2022/08/16 11:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -24,7 +24,6 @@
24 24  
25 25  = 1. Introduction =
26 26  
27 -
28 28  == 1.1 What is LWL02 LoRaWAN Water Leak Sensor ==
29 29  
30 30  
... ... @@ -50,7 +50,6 @@
50 50  
51 51  == 1.2 Features ==
52 52  
53 -
54 54  * LoRaWAN Class A v1.0.3
55 55  * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
56 56  * SX1262 LoRa Core
... ... @@ -62,10 +62,8 @@
62 62  * Firmware upgradable via program port
63 63  
64 64  
65 -
66 66  == 1.3 Applications ==
67 67  
68 -
69 69  * Smart Buildings & Home Automation
70 70  * Logistics and Supply Chain Management
71 71  * Smart Metering
... ... @@ -74,10 +74,8 @@
74 74  * Smart Factory
75 75  
76 76  
77 -
78 78  == 1.4 Dimension ==
79 79  
80 -
81 81  [[image:image-20220608143952-2.png]]
82 82  
83 83  [[image:1654670405145-346.png]]
... ... @@ -86,30 +86,24 @@
86 86  
87 87  == 1.5 Firmware Change log ==
88 88  
89 -
90 90  (((
91 -LWL02 use the same firmware as LDS01:  [[https:~~/~~/www.dropbox.com/sh/6ls5i0zsvujvbc8/AABe3V5aQXdy7zSxEdEA3DHOa?dl=0>>https://www.dropbox.com/sh/6ls5i0zsvujvbc8/AABe3V5aQXdy7zSxEdEA3DHOa?dl=0]]
84 +LWL02 use the same firmware as LDS01.
92 92  )))
93 93  
94 94  (((
95 -
88 +[[LWL02 Image files – Download link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
96 96  )))
97 97  
98 98  
99 99  = 2. Power ON LWL02 =
100 100  
101 -
102 102  When receive the LWL02, please open the enclosure and add 2 x AAA batteries to power it. The [[LED>>||anchor="H4.7LEDs"]] will blink when device is powered.
103 103  
104 104  
105 -
106 106  = 3. How to install LWL02 =
107 107  
108 -
109 109  (((
110 110  When install the LWL02 on wall. Please install as below so the water leak probe will be soak in water for water detect purpose. The LWL02 main body is not water proof. Please don't let water go inside the LWL02 main body.
111 -
112 -
113 113  )))
114 114  
115 115  [[image:image-20220608144447-4.png]]
... ... @@ -118,10 +118,8 @@
118 118  
119 119  = 4. Operation Mode =
120 120  
121 -
122 122  == 4.1 How it works? ==
123 123  
124 -
125 125  (((
126 126  The LWL02 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and [[power on>>||anchor="H2.PowerONLWL02"]] the LWL02. It will auto join the network via OTAA.
127 127  )))
... ... @@ -131,10 +131,8 @@
131 131  )))
132 132  
133 133  
134 -
135 135  == 4.2 Example to join LoRaWAN network ==
136 136  
137 -
138 138  Here shows an example for how to join the [[TTN V3 Network>>url:https://eu1.cloud.thethings.network/]]. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
139 139  
140 140  [[image:1654671007127-335.png]]
... ... @@ -176,7 +176,6 @@
176 176  
177 177  User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
178 178  
179 -
180 180  **Add APP EUI in the application**
181 181  
182 182  [[image:1654671794691-956.png]]
... ... @@ -195,7 +195,6 @@
195 195  [[image:1654671889112-678.png]]
196 196  
197 197  
198 -
199 199  (% style="color:blue" %)**Step 2**(%%): **[[Power on>>||anchor="H2.PowerONLWL02"]]** LWL02 and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
200 200  
201 201  
... ... @@ -217,11 +217,10 @@
217 217  
218 218  
219 219  (((
220 -Example Payload Decoder in TTN V3:  [[https:~~/~~/www.dropbox.com/sh/01rpk03gupwzkg2/AAACzAaN2I4MC-rw7oltfzUta?dl=0>>https://www.dropbox.com/sh/01rpk03gupwzkg2/AAACzAaN2I4MC-rw7oltfzUta?dl=0]]
202 +Example Payload Decoder in TTN V3: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Payload/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Payload/]]
221 221  )))
222 222  
223 223  
224 -
225 225  == 4.4 Downlink Payload ==
226 226  
227 227  
... ... @@ -286,10 +286,8 @@
286 286  See [[Alarm Base Timeout>>||anchor="H4.6AlarmBaseonTimeout"]] for detail.
287 287  
288 288  
289 -
290 290  == 4.5 Integrate with Datacake ==
291 291  
292 -
293 293  (((
294 294  Datacake provides a human friendly interface to show the sensor data, once we have data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
295 295  )))
... ... @@ -316,10 +316,8 @@
316 316  [[image:1654674556510-911.png]]
317 317  
318 318  
319 -
320 320  == 4.6 Alarm Base on Timeout ==
321 321  
322 -
323 323  (((
324 324  LWL02 can monitor the timeout for a status change, this feature can be used to monitor some event such as monitoring water leakage duration etc.
325 325  )))
... ... @@ -337,7 +337,7 @@
337 337  )))
338 338  
339 339  * (((
340 -(% style="color:red" %)**AT+TTRIG=1,30 **(%%) **~-~->** When status change from close to open, and device keep in open
317 +**AT+TTRIG=1,30 ** **~-~->** When status change from close to open, and device keep in open
341 341  )))
342 342  
343 343  (((
... ... @@ -345,10 +345,7 @@
345 345  )))
346 346  
347 347  * (((
348 -(% style="color:red" %)**AT+TTRIG=0,0** (%%) **~-~->**  Default Value, disable timeout Alarm.
349 -
350 -
351 -
325 +**AT+TTIG=0,0**  **~-~->**  Default Value, disable timeout Alarm.
352 352  )))
353 353  
354 354  (((
... ... @@ -385,9 +385,6 @@
385 385  
386 386  (((
387 387  0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm.
388 -
389 -
390 -
391 391  )))
392 392  
393 393  == 4.7 LEDs ==
... ... @@ -401,13 +401,10 @@
401 401  |(% style="width:184px" %)Got a downlink message|(% style="width:275px" %)(% style="color:blue" %)**BLUE LED**(%%) blinks once
402 402  
403 403  
404 -
405 405  = 5. Battery & How to replace =
406 406  
407 -
408 408  == 5.1 Battery Type and replace ==
409 409  
410 -
411 411  (((
412 412  LWL02 is equipped with 2 x AAA LR03 batteries. If the batteries running low(see 2.1v in the platform). User can buy generic AAA battery and replace it. Note:
413 413  )))
... ... @@ -434,10 +434,8 @@
434 434  [[image:1654675278044-307.png]]
435 435  
436 436  
437 -
438 438  == 5.2 Power Consumption Analyze ==
439 439  
440 -
441 441  (((
442 442  Dragino battery powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimate battery life:
443 443  )))
... ... @@ -447,16 +447,12 @@
447 447  )))
448 448  
449 449  
450 -
451 451  = 6. Use AT Command =
452 452  
453 -
454 454  == 6.1 Access AT Command ==
455 455  
456 -
457 457  LWL02 supports AT Command set. User can use a USB to TTL adapter to configure LWL02 via use AT command, as below.
458 458  
459 -
460 460  [[image:image-20220608160336-1.png]]
461 461  
462 462  
... ... @@ -479,13 +479,12 @@
479 479  
480 480  [[image:1654675618022-630.png]]
481 481  
482 -
483 483  (((
484 484  Each AT Command need to (% style="color:red" %)**add an ENTER**(%%) at the end before send.
485 485  )))
486 486  
487 487  (((
488 -When entering the first command, the (% style="color:red" %)**RED LED**(%%) will on and user can now input AT Commands. After input all needed AT Commands, please input **AT+CLPM=1** to set the device to work in Low Power mode and (% style="color:red" %)**RED LED**(%%) will be off.
449 +When entering the first command, the (% style="color:red" %)**RED LED**(%%) will on and user can now input AT Commands. After input all needed AT Commands, please input AT+CLPM=1 to set the device to work in Low Power mode and (% style="color:red" %)**RED LED**(%%) will be off.
489 489  )))
490 490  
491 491  (((
... ... @@ -493,48 +493,38 @@
493 493  )))
494 494  
495 495  
496 -
497 497  = 7. FAQ =
498 498  
499 -
500 500  == 7.1 How to upgrade the image? ==
501 501  
502 -
503 503  User can upgrade the of LWL02 for bug fix, new features, or change working region. The upgrade instruction is here: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
504 504  
505 505  
506 -
507 507  == 7.2 How to change the LoRa Frequency Bands/Region? ==
508 508  
509 -
510 510  If user has for example US915 frequency and want to change it to AS923 frequency. User can follow the introduction for [[how to upgrade image>>||anchor="H7.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
511 511  
512 512  
513 -
514 514  == 7.3 Can I disable uplink for each event to save battery life? ==
515 515  
516 -
517 517  Yes, User can use below method to disable this:
518 518  
473 +(% style="color:#4f81bd" %)**via AT Command**:
519 519  
520 -(% style="color:blue" %)**via AT Command**:
475 +AT+DISALARM=1,  End node will only send packet in TDC time.
521 521  
522 -(% style="color:red" %)**AT+DISALARM=1**(%%),  End node will only send packet in TDC time.
477 +AT+DISALARM=0,  End node will send packet in TDC time or status change for door sensor. 
523 523  
524 -(% style="color:red" %)**AT+DISALARM=0**(%%),  End node will send packet in TDC time or status change for door sensor. 
525 525  
480 +(% style="color:#4f81bd" %)**via LoRaWAN downlink Command**:
526 526  
527 -(% style="color:blue" %)**via LoRaWAN downlink Command**:
482 +0xA701 :  Equal to AT+DISALARM=1
528 528  
529 -(% style="color:red" %)**0xA701** (%%):  Equal to AT+DISALARM=1
484 +0xA700 :  Equal to AT+DISALARM=0
530 530  
531 -(% style="color:red" %)**0xA700** (%%):  Equal to AT+DISALARM=0
532 532  
533 -
534 -
535 535  = 8. Order Info =
536 536  
537 -
538 538  **Part Number: (% style="color:blue" %)LWL02-XXX(%%)**
539 539  
540 540  (% style="color:blue" %)**XXX:**
... ... @@ -550,20 +550,15 @@
550 550  * (% style="color:red" %)**CN779**(%%): frequency bands CN779
551 551  
552 552  
553 -
554 -
555 555  = 9. Packing Info =
556 556  
557 -
558 558  **Package Includes**:
559 559  
560 560  * LWL02 x 1
561 561  
562 562  
563 -
564 564  = 10. Support =
565 565  
566 -
567 567  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
568 568  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
569 569  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0