<
From version < 40.2 >
edited by Xiaoling
on 2022/08/18 17:56
To version < 39.1 >
edited by Bei Jinggeng
on 2022/08/16 11:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -24,7 +24,6 @@
24 24  
25 25  = 1. Introduction =
26 26  
27 -
28 28  == 1.1 What is LWL02 LoRaWAN Water Leak Sensor ==
29 29  
30 30  
... ... @@ -50,7 +50,6 @@
50 50  
51 51  == 1.2 Features ==
52 52  
53 -
54 54  * LoRaWAN Class A v1.0.3
55 55  * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
56 56  * SX1262 LoRa Core
... ... @@ -62,11 +62,8 @@
62 62  * Firmware upgradable via program port
63 63  
64 64  
65 -
66 -
67 67  == 1.3 Applications ==
68 68  
69 -
70 70  * Smart Buildings & Home Automation
71 71  * Logistics and Supply Chain Management
72 72  * Smart Metering
... ... @@ -75,11 +75,8 @@
75 75  * Smart Factory
76 76  
77 77  
78 -
79 -
80 80  == 1.4 Dimension ==
81 81  
82 -
83 83  [[image:image-20220608143952-2.png]]
84 84  
85 85  [[image:1654670405145-346.png]]
... ... @@ -88,30 +88,24 @@
88 88  
89 89  == 1.5 Firmware Change log ==
90 90  
91 -
92 92  (((
93 -LWL02 use the same firmware as LDS01:  [[https:~~/~~/www.dropbox.com/sh/6ls5i0zsvujvbc8/AABe3V5aQXdy7zSxEdEA3DHOa?dl=0>>https://www.dropbox.com/sh/6ls5i0zsvujvbc8/AABe3V5aQXdy7zSxEdEA3DHOa?dl=0]]
84 +LWL02 use the same firmware as LDS01.
94 94  )))
95 95  
96 96  (((
97 -
88 +[[LWL02 Image files – Download link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
98 98  )))
99 99  
100 100  
101 101  = 2. Power ON LWL02 =
102 102  
103 -
104 104  When receive the LWL02, please open the enclosure and add 2 x AAA batteries to power it. The [[LED>>||anchor="H4.7LEDs"]] will blink when device is powered.
105 105  
106 106  
107 -
108 108  = 3. How to install LWL02 =
109 109  
110 -
111 111  (((
112 112  When install the LWL02 on wall. Please install as below so the water leak probe will be soak in water for water detect purpose. The LWL02 main body is not water proof. Please don't let water go inside the LWL02 main body.
113 -
114 -
115 115  )))
116 116  
117 117  [[image:image-20220608144447-4.png]]
... ... @@ -120,10 +120,8 @@
120 120  
121 121  = 4. Operation Mode =
122 122  
123 -
124 124  == 4.1 How it works? ==
125 125  
126 -
127 127  (((
128 128  The LWL02 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and [[power on>>||anchor="H2.PowerONLWL02"]] the LWL02. It will auto join the network via OTAA.
129 129  )))
... ... @@ -133,10 +133,8 @@
133 133  )))
134 134  
135 135  
136 -
137 137  == 4.2 Example to join LoRaWAN network ==
138 138  
139 -
140 140  Here shows an example for how to join the [[TTN V3 Network>>url:https://eu1.cloud.thethings.network/]]. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
141 141  
142 142  [[image:1654671007127-335.png]]
... ... @@ -178,7 +178,6 @@
178 178  
179 179  User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
180 180  
181 -
182 182  **Add APP EUI in the application**
183 183  
184 184  [[image:1654671794691-956.png]]
... ... @@ -197,7 +197,6 @@
197 197  [[image:1654671889112-678.png]]
198 198  
199 199  
200 -
201 201  (% style="color:blue" %)**Step 2**(%%): **[[Power on>>||anchor="H2.PowerONLWL02"]]** LWL02 and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
202 202  
203 203  
... ... @@ -219,11 +219,10 @@
219 219  
220 220  
221 221  (((
222 -Example Payload Decoder in TTN V3:  [[https:~~/~~/www.dropbox.com/sh/01rpk03gupwzkg2/AAACzAaN2I4MC-rw7oltfzUta?dl=0>>https://www.dropbox.com/sh/01rpk03gupwzkg2/AAACzAaN2I4MC-rw7oltfzUta?dl=0]]
202 +Example Payload Decoder in TTN V3: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Payload/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Payload/]]
223 223  )))
224 224  
225 225  
226 -
227 227  == 4.4 Downlink Payload ==
228 228  
229 229  
... ... @@ -288,10 +288,8 @@
288 288  See [[Alarm Base Timeout>>||anchor="H4.6AlarmBaseonTimeout"]] for detail.
289 289  
290 290  
291 -
292 292  == 4.5 Integrate with Datacake ==
293 293  
294 -
295 295  (((
296 296  Datacake provides a human friendly interface to show the sensor data, once we have data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
297 297  )))
... ... @@ -318,10 +318,8 @@
318 318  [[image:1654674556510-911.png]]
319 319  
320 320  
321 -
322 322  == 4.6 Alarm Base on Timeout ==
323 323  
324 -
325 325  (((
326 326  LWL02 can monitor the timeout for a status change, this feature can be used to monitor some event such as monitoring water leakage duration etc.
327 327  )))
... ... @@ -339,7 +339,7 @@
339 339  )))
340 340  
341 341  * (((
342 -(% style="color:red" %)**AT+TTRIG=1,30 **(%%) **~-~->** When status change from close to open, and device keep in open
317 +**AT+TTRIG=1,30 ** **~-~->** When status change from close to open, and device keep in open
343 343  )))
344 344  
345 345  (((
... ... @@ -347,10 +347,7 @@
347 347  )))
348 348  
349 349  * (((
350 -(% style="color:red" %)**AT+TTRIG=0,0** (%%) **~-~->**  Default Value, disable timeout Alarm.
351 -
352 -
353 -
325 +**AT+TTIG=0,0**  **~-~->**  Default Value, disable timeout Alarm.
354 354  )))
355 355  
356 356  (((
... ... @@ -387,9 +387,6 @@
387 387  
388 388  (((
389 389  0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm.
390 -
391 -
392 -
393 393  )))
394 394  
395 395  == 4.7 LEDs ==
... ... @@ -403,14 +403,10 @@
403 403  |(% style="width:184px" %)Got a downlink message|(% style="width:275px" %)(% style="color:blue" %)**BLUE LED**(%%) blinks once
404 404  
405 405  
406 -
407 -
408 408  = 5. Battery & How to replace =
409 409  
410 -
411 411  == 5.1 Battery Type and replace ==
412 412  
413 -
414 414  (((
415 415  LWL02 is equipped with 2 x AAA LR03 batteries. If the batteries running low(see 2.1v in the platform). User can buy generic AAA battery and replace it. Note:
416 416  )))
... ... @@ -437,10 +437,8 @@
437 437  [[image:1654675278044-307.png]]
438 438  
439 439  
440 -
441 441  == 5.2 Power Consumption Analyze ==
442 442  
443 -
444 444  (((
445 445  Dragino battery powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimate battery life:
446 446  )))
... ... @@ -450,16 +450,12 @@
450 450  )))
451 451  
452 452  
453 -
454 454  = 6. Use AT Command =
455 455  
456 -
457 457  == 6.1 Access AT Command ==
458 458  
459 -
460 460  LWL02 supports AT Command set. User can use a USB to TTL adapter to configure LWL02 via use AT command, as below.
461 461  
462 -
463 463  [[image:image-20220608160336-1.png]]
464 464  
465 465  
... ... @@ -482,13 +482,12 @@
482 482  
483 483  [[image:1654675618022-630.png]]
484 484  
485 -
486 486  (((
487 487  Each AT Command need to (% style="color:red" %)**add an ENTER**(%%) at the end before send.
488 488  )))
489 489  
490 490  (((
491 -When entering the first command, the (% style="color:red" %)**RED LED**(%%) will on and user can now input AT Commands. After input all needed AT Commands, please input **AT+CLPM=1** to set the device to work in Low Power mode and (% style="color:red" %)**RED LED**(%%) will be off.
449 +When entering the first command, the (% style="color:red" %)**RED LED**(%%) will on and user can now input AT Commands. After input all needed AT Commands, please input AT+CLPM=1 to set the device to work in Low Power mode and (% style="color:red" %)**RED LED**(%%) will be off.
492 492  )))
493 493  
494 494  (((
... ... @@ -496,48 +496,38 @@
496 496  )))
497 497  
498 498  
499 -
500 500  = 7. FAQ =
501 501  
502 -
503 503  == 7.1 How to upgrade the image? ==
504 504  
505 -
506 506  User can upgrade the of LWL02 for bug fix, new features, or change working region. The upgrade instruction is here: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
507 507  
508 508  
509 -
510 510  == 7.2 How to change the LoRa Frequency Bands/Region? ==
511 511  
512 -
513 513  If user has for example US915 frequency and want to change it to AS923 frequency. User can follow the introduction for [[how to upgrade image>>||anchor="H7.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
514 514  
515 515  
516 -
517 517  == 7.3 Can I disable uplink for each event to save battery life? ==
518 518  
519 -
520 520  Yes, User can use below method to disable this:
521 521  
473 +(% style="color:#4f81bd" %)**via AT Command**:
522 522  
523 -(% style="color:blue" %)**via AT Command**:
475 +AT+DISALARM=1,  End node will only send packet in TDC time.
524 524  
525 -**(% style="color:red" %)AT+DISALARM=1**(%%),  End node will only send packet in TDC time.
477 +AT+DISALARM=0,  End node will send packet in TDC time or status change for door sensor. 
526 526  
527 -**(% style="color:red" %)AT+DISALARM=0**(%%),  End node will send packet in TDC time or status change for door sensor. 
528 528  
480 +(% style="color:#4f81bd" %)**via LoRaWAN downlink Command**:
529 529  
530 -(% style="color:blue" %)**via LoRaWAN downlink Command**:
482 +0xA701 :  Equal to AT+DISALARM=1
531 531  
532 -**(% style="color:red" %)0xA701** (%%):  Equal to AT+DISALARM=1
484 +0xA700 :  Equal to AT+DISALARM=0
533 533  
534 -**(% style="color:red" %)0xA700** (%%):  Equal to AT+DISALARM=0
535 535  
536 -
537 -
538 538  = 8. Order Info =
539 539  
540 -
541 541  **Part Number: (% style="color:blue" %)LWL02-XXX(%%)**
542 542  
543 543  (% style="color:blue" %)**XXX:**
... ... @@ -553,24 +553,16 @@
553 553  * (% style="color:red" %)**CN779**(%%): frequency bands CN779
554 554  
555 555  
556 -
557 -
558 -
559 559  = 9. Packing Info =
560 560  
561 -
562 562  **Package Includes**:
563 563  
564 564  * LWL02 x 1
565 565  
566 566  
567 -
568 -
569 569  = 10. Support =
570 570  
571 -
572 572  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
573 573  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
574 574  
575 -
576 576  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0