Changes for page LWL02 -- LoRaWAN Water Leak Sensor User Manual
Last modified by Mengting Qiu on 2024/05/29 11:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,14 +3,10 @@ 3 3 4 4 5 5 6 -**Contents:** 7 7 8 -{{toc/}} 9 9 10 10 11 11 12 - 13 - 14 14 = 1. Introduction = 15 15 16 16 == 1.1 What is LWL02 LoRaWAN Water Leak Sensor == ... ... @@ -185,7 +185,7 @@ 185 185 |=(% style="width: 180px;" %)**Downlink Control Type**|=(% style="width: 80px;" %)**Type Code**|=(% style="width: 150px;" %)**Downlink payload size(bytes)** 186 186 |(% style="width:180px" %)TDC (Transmit Time Interval—Keep Alive Interval)|(% style="width:80px" %)0x01|(% style="width:150px" %)4 187 187 |(% style="width:180px" %)RESET|(% style="width:80px" %)0x04|(% style="width:224px" %)2 188 -|(% style="width:180px" %)[[Set confirmed mode>> ||anchor="H"]]|(% style="width:80px" %)0x05|(% style="width:150px" %)2184 +|(% style="width:180px" %)[[Set confirmed mode>>path:#code05]]|(% style="width:80px" %)0x05|(% style="width:150px" %)2 189 189 |(% style="width:180px" %)[[Clear Counting>>path:#codeA6]]|(% style="width:80px" %)0xA6|(% style="width:150px" %)2 190 190 |(% style="width:180px" %)[[Enable/Disable Alarm>>path:#code70]]|(% style="width:80px" %)0xA7|(% style="width:150px" %)2 191 191 |(% style="width:180px" %)[[Control ADR/DR>>path:#codeA8]]|(% style="width:80px" %)0xA8|(% style="width:150px" %)3 ... ... @@ -196,17 +196,17 @@ 196 196 [[image:1654673412319-976.png]] 197 197 198 198 199 - === (% style="color:#037691" %)**Type Code 0x01**(%%) ===195 +**Type Code 0x01** 200 200 201 201 If the payload=0100003C, means to control the LWL02’s Keep Alive interval to 0x00003C=60(S) 202 202 203 203 204 - === (% style="color:#037691" %)**Type Code 0x04**(%%) ===200 +**Type Code 0x04** 205 205 206 206 If payload = 0x04FF, it will reset the LWL02. 207 207 208 208 209 - === (% style="color:#037691" %)**Type Code 0x05**(%%) ===205 +**Type Code 0x05** 210 210 211 211 0x05 00: Set uplink to LoRaWAN unconfirmed mode 212 212 ... ... @@ -213,13 +213,13 @@ 213 213 0x05 01: Set uplink to LoRaWAN confirmed mode 214 214 215 215 216 - === (% style="color:#037691" %)**Type Code 0xA6**(%%) ===212 +**Type Code 0xA6** 217 217 218 218 Example: 0xA601: Clear Counting 219 219 For LWL02: reset both count number and time. 220 220 221 221 222 - === (% style="color:#037691" %)**Type Code 0xA7**(%%) ===218 +**Type Code 0xA7** 223 223 224 224 0xA7 01 : Equal to AT+DISALARM=1 225 225 ... ... @@ -226,7 +226,7 @@ 226 226 0xA7 00 : Equal to AT+DISALARM=0 227 227 228 228 229 - === (% style="color:#037691" %)**Type Code 0xA8**(%%) ===225 +**Type Code 0xA8** 230 230 231 231 Format: 0xA8 aa bb 232 232 ... ... @@ -237,7 +237,7 @@ 237 237 Example: 0x A8 00 02 : Set ADR=0 and DR=1 238 238 239 239 240 - === (% style="color:#037691" %)**Type Code 0xA9**(%%) ===236 +**Type Code 0xA9** 241 241 242 242 See [[Alarm Base Timeout>>path:#Alarm_Timeout]] for detail. 243 243 ... ... @@ -440,4 +440,3 @@ 440 440 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 441 441 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 442 442 443 -