12
13 = 1.Door sensor =
14
15
16 Application: Connect to Door Sensor detect door open / close and send to IoT server
17
18 Sensor Type: Normal Close Type Door Sensor as below
19
20 [[image:image-20240424100239-8.png||height="227" width="946"]]
21
22
23 == 1.1 Hardware Connection ==
24
25 * (((
26 LHT65N VDD <~-~-> one wire of Door Sensor
27 )))
28 * (((
29 LHT65N Interrupt Pin <~-~-> one wire of Door Sensor
30 )))
31
32 [[image:image-20240424100415-9.png||height="355" width="796"]]
33
34 == 1.2 Software Configuration ==
35
36 Set LHT65N to Interrupt Mode so device will uplink when there is open/close event
37
38 * (((
39 AT Command : AT+EXT=4,1
40 )))
41 * (((
42 Downlink Command: 0xA20401 :   Same as AT+EXT=4,1
43 )))
44
45 Enlarge the TDC time so LHT65N will send Keep Alive message every 24 hours so to save battery life.
46
47 * (((
48 AT Command :AT+TDC=86400000
49 )))
50 * (((
51 Downlink Command:  0x01015180   Same as AT+TDC=86400000
52 )))
53
54 == 1.3 Test Result ==
55
56 Move the magnet part to generate Open / Close event and check the uplink packet in the platform.
57
58 [[image:image-20240424100951-10.jpeg||height="333" width="741"]]
59
60 [[image:image-20240424100951-11.png||height="280" width="1247"]]
61
62
63 == 1.4 Power Consumption Notice ==
64
65
66 Connect a Normal Close Door Sensor won't increase sleep current (~~6uA). The power consumption mainly depends on the how many open/close event happen every day.
67
68
69
70
71 = 2. Water Sensor =
72
73
74 Application: Connect to Water leakage Sensor detect door open / close and send to IoT server
75
76
77 == 2.1 Hardware Connection ==
78
79 * LHT65N VDD <~-~-> one wire of water leakage Sensor
80 * LHT65N Interrupt Pin <~-~-> one wire of water leakage Sensor
81
82 == 2.2  Software Configuration ==
83
84 Set LHT65N to Interrupt Mode so device will uplink when there is open/close event
85
86 * AT Command : AT+EXT=4,1
87 * Downlink Command:  0xA20401 :   Same as AT+EXT=4,1
88
89 Enlarge the TDC time so LHT65N will send Keep Alive message every 24 hours so to save battery life.
90
91 * AT Command :AT+TDC=86400000
92 * Downlink Command:  01015180  Same as AT+TDC=86400000
93
94 == 2.3 Test Result ==
95
96
97 Partial contact of the sensor probe with water generates open/close events and checks for upstream packets in the platform.
98
99 [[image:image-20240424101908-12.png||height="331" width="435"]]
100
101 [[image:image-20240424101927-13.png||height="303" width="766"]]
102
103
104 == 2.4 Power Consumption Notice ==
105
106 * Connecting the water leak sensor increases the sleep current (~~40uA). When using a water leak sensor, the battery life will be reduced.
107
108 [[image:image-20240424102048-14.png||height="495" width="926"]]
109
110 When the probe comes into contact with water, it will increase the low power consumption by about 300uA.
111
112 Then when it is out of contact with water, the power consumption will slowly drop. The reason for the slow drop is that there are water beads hanging on the surface of the probe. When it dries, It will reduce power consumption.
113
114
115
116 = 3 Smoke Sensor =
117
118 Application:  Mainly suitable for hotels, warehouses, guesthouses, restaurants, hostels, factories, oil field well teams, prefabricated houses and other public places.When it is detected that the smoke in the air reaches a certain concentration value, an alarm signal is triggered immediately. False alarms are likely to occur when dew, oil smoke, water vapor, sudden temperature changes, corrosive gases, strong airflow or air conditioning, or outdoor environments occur.
119
120 * Technical Notes:
121
122 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
123 |=(% style="width: 156px;background-color:#4F81BD;color:white" %)**Parameter name**|=(% style="width: 137px;background-color:#4F81BD;color:white" %)**Explanation**
124 |(% style="width:156px" %)Power|(% style="width:137px" %)DC 3V(Two 1.5V alkaline batteries)
125 |(% style="width:156px" %)Indicator lights|(% style="width:137px" %)It will flash once every minute in the monitoring state, and it will stay on when smoke is detected.
126 |(% style="width:156px" %)Working temperature|(% style="width:137px" %)-10℃~~+50℃
127 |(% style="width:156px" %)Working humidity|(% style="width:137px" %)≤95% (Under 40℃ working environment)
128
129 == 3.1 Hardware Connection ==
130
131 * LHT65N VDD <~-~-> Sound vibration film red line
132 * LHT65N Interrupt Pin <~-~-> sound vibration film black line
133
134 [[image:image-20240428090354-1.jpeg||height="456" width="1015"]]
135
136
137 == 3.2 Software Configuration ==
138
139
140 Set LHT65N to Interrupt Mode so device will uplink when there is open/close event
141
142 * AT Command : AT+EXT=4,1
143 * Downlink Command:  0xA20401 :   Same as AT+EXT=4,1
144
145 Enlarge the TDC time so LHT65N will send Keep Alive message every 24 hours so to save battery life.
146
147 * AT Command :AT+TDC=86400000
148 * Downlink Command:  01015180  Same as AT+TDC=86400000
149
150 == 3.3 Test Result ==
151
152
153 [[image:image-20240428090354-2.png||height="771" width="1011"]]
154
155 [[image:image-20240428090354-3.png||height="314" width="1015"]]
156
157 When triggered, the node will send data packets twice. When it is not triggered or the trigger ends, it needs to wait for the TDC time to send data packets.
158
159
160 == 3.4 Power Consumption Notice ==
161
162 When there is smoke detect, the smoke sensor will be trigger , there will be sound from speaker and trigger the LHT65N to send uplink
163
164
165
166 = 4. SOS switch sensor =
167
168 Application:Connected to the SOS switch, the sensor detects whether an alarm is triggered and sends it to the IoT server.
169
170 When the red button is pressed, 1 and 2 are connected, and 1 and 3 are disconnected. When you release your hand, the red button automatically pops up, 1 and 2 are disconnected, 1 and 3 are connected, and it automatically resets without a key; This emergency help button is used for emergencies or emergencies. Press this red button to give an alarm and SOS emergency call (COM is 1, NO is 2, NC is 3)
171
172 == 4.1 Hardware Connection ==
173
174
175 LHT65N VDD <~-~--> COM port of the SOS button
176
177 LHT65N Interrupt Pin <~-~-> The NO port of the SOS button
178
179 [[image:image-20240429133616-4.jpeg||height="937" width="1065"]]
180
181
182 == 4.2 Software Configuration ==
183
184
185 Set LHT65N to Interrupt Mode so device will uplink when there is open/close event
186
187 * AT Command : AT+EXT=4,1
188 * Downlink Command:  0xA20401 :   Same as AT+EXT=4,1
189
190 Enlarge the TDC time so LHT65N will send Keep Alive message every 24 hours so to save battery life.
191
192 * AT Command :AT+TDC=86400000
193 * Downlink Command:  01015180  Same as AT+TDC=86400000
194
195 == 4.3 Test Result ==
196
197 [[image:image-20240429133616-5.jpeg||height="685" width="753"]]
198
199 Note: When the LHT65N triggers an interrupt packet, it needs to wait 6s before a new trigger is generated.
200
201 When the button is pressed, the SOS button will be triggered, and the LHT65N will also be triggered to send the uplink signal.
202
203
204 == 4.4 Power Consumption Notice ==
205
206 Connect SOS button Sensor won't increase sleep current (~~6uA). The power consumption mainly depends on the how many open/close event happen every day.
207
208
209 = 5. Flow sensor =
210
211 Application: It detects water flow volume and uplink to IoT server via LoRaWAN network. User can use this to monitor the water usage for buildings.
212
213 == 5.1 Hardware Connection ==
214
215 LHT65N VDD <~-~--> Flow sensor red line
216
217 LHT65N Interrupt Pin <~-~-> Flow sensor Signal line
218
219 LHT65N GND <~-~--> Flow sensor black line(Note: If the sensor does not need power supply, please connect the red line (rising edge trigger) or the black line (falling edge trigger) as needed.)
220
221 [[image:image-20240506111329-1.jpeg||height="654" width="388"]]
222
223
224 == 5.2 Software Configuration ==
225
226 Note: Because the traffic sensor is a counting sensor, the node can only be set in counting mode.
227
228 Set LHT65N to Counting Mode so device will uplink when there is open/close event
229
230 * AT Command : AT+EXT=8,1
231 * Downlink Command:  0xA2080101 :   Same as AT+EXT=8,1
232
233
234 Enlarge the TDC time so LHT65N will send Keep Alive message every 24 hours so to save battery life.
235
236 * AT Command :AT+TDC=86400000
237 * Downlink Command:  01015180  Same as AT+TDC=86400000
238
239
240 == 5.3 Test Result ==
241
242 [[image:image-20240506111329-2.jpeg||height="533" width="336"]]
243
244 When the water passes through the flow sensor, the cumulative count will be generated (note: when installing the flow sensor, it is necessary to pay attention to the inlet direction of the installation).
245
246 [[image:image-20240506111329-3.png||height="377" width="1134"]]
247
248
249 == 5.4 Power Consnmption Notice ==
250
251 Connect Flow Sensor won't increase sleep current (~~6uA). The power consumption mainly depends on the how many counting event happen every day.