Show last authors
1 (% style="text-align:center" %)
2 [[image:1654592399090-860.png||height="521" width="483"]]
3
4
5
6
7 **Contents:**
8
9 * [[1. Introduction>>path:#H1.Introduction]]
10 ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 ** [[​1.2 Features>>path:#H200B1.2Features]]
12 ** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 ** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 ** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 * [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 ** [[2.1 How it works>>path:#H2.1Howitworks]]
17 ** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 ** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 *** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 *** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 *** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 *** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 *** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 *** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 *** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 ** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 ** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 ** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 *** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 *** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 *** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 ** [[2.7 Calibration>>path:#H2.7Calibration]]
33 ** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 *** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 *** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 *** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 *** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 *** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 *** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 *** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 ** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 ** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 * [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 ** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 ** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 ** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 ** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 * [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 ** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 ** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 ** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 *** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 *** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 * [[5. Use AT Command>>path:#H5.UseATCommand]]
55 ** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 * [[6. FAQ>>path:#H6.FAQ]]
57 ** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 * [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 ** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 * [[8. Order Info>>path:#H8.OrderInfo]]
61 * [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 * [[10. ​Support>>path:#H10.A0200BSupport]]
63
64
65
66
67
68
69
70
71
72
73 = 1. Introduction =
74
75 == 1.1 ​What is LoRaWAN Soil pH Sensor ==
76
77 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
78
79 LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use.
80
81 The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
82
83 LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
84
85 Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
86
87
88 [[image:1654592435432-887.png]]
89
90
91
92 == ​1.2 Features ==
93
94 * LoRaWAN 1.0.3 Class A
95 * Ultra-low power consumption
96 * Monitor soil pH with temperature compensation.
97 * Monitor soil temperature
98 * Monitor Battery Level
99 * Support pH calibration by end user
100 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
101 * AT Commands to change parameters
102 * Uplink on periodically
103 * Downlink to change configure
104 * IP66 Waterproof Enclosure
105 * IP68 rate for the Sensor Probe
106 * 8500mAh Battery for long term use
107
108
109 == 1.3 Probe Specification ==
110
111
112 (% style="color:#4f81bd" %)**Soil pH:**
113
114 * Range: 3 ~~ 10 pH
115 * Resolution: 0.01 pH
116 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen)
117 * Temperature Compensation Range: 0 ~~ 50℃
118 * IP68 Protection
119 * Length: 3.5 meters
120
121 (% style="color:#4f81bd" %)**Soil Temperature:**
122
123 * Range -40℃~85℃
124 * Resolution: 0.1℃
125 * Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others)
126 * IP68 Protection
127 * Length: 3.5 meters
128
129
130 == 1.4 ​Applications ==
131
132 * Smart Agriculture
133
134
135 == 1.5 Pin mapping and power on ==
136
137 [[image:1654592472094-134.png]]
138
139
140
141 = 2. Configure LSPH01 to connect to LoRaWAN network =
142
143 == 2.1 How it works ==
144
145 (((
146 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
147 )))
148
149 (((
150 In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
151 )))
152
153
154 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
155
156 (((
157 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
158 )))
159
160 (((
161 [[image:1654592492399-921.png]]
162 )))
163
164 (((
165 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
166 )))
167
168 (((
169 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.
170 )))
171
172 (((
173 Each LSPH01 is shipped with a sticker with the default device EUI as below:
174 )))
175
176 [[image:image-20220607170145-1.jpeg]]
177
178
179
180 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
181
182
183 **Register the device**
184
185
186 [[image:1654592600093-601.png]]
187
188
189 **Add APP EUI and DEV EUI**
190
191 [[image:1654592619856-881.png]]
192
193
194 **Add APP EUI in the application**
195
196 [[image:1654592632656-512.png]]
197
198
199
200 **Add APP KEY**
201
202 [[image:1654592653453-934.png]]
203
204
205 (% style="color:blue" %)**Step 2**(%%): Power on LSPH01
206
207
208 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
209
210 [[image:image-20220607170442-2.png]]
211
212
213 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
214
215 [[image:1654592697690-910.png]]
216
217
218
219 == 2.3 ​Uplink Payload ==
220
221 LSPH01 will uplink payload via LoRaWAN with below payload format: 
222
223 Uplink payload includes in total 11 bytes.
224
225 Normal uplink payload:
226
227 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
228 |(((
229 **Size**
230
231 **(bytes)**
232 )))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
233 |**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
234 [[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
235
236 [[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
237 )))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
238 [[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
239 )))|Reserve|(((
240 [[Message Type>>path:#H2.3.6MessageType]]
241 )))
242
243 [[image:1654592721645-318.png]]
244
245
246
247 === 2.3.1 Battery Info ===
248
249
250 Check the battery voltage for LSPH01.
251
252 Ex1: 0x0B45 = 2885mV
253
254 Ex2: 0x0B49 = 2889mV
255
256
257
258 === 2.3.2 DS18B20 Temperature sensor ===
259
260 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
261
262
263 **Example**:
264
265 If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
266
267 If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
268
269
270
271 === 2.3.3 Soil pH ===
272
273 Range: 0 ~~ 14 pH
274
275 **Example:**
276
277 (% style="color:#037691" %)** 0x02B7(H) = 695(D) = 6.95pH**
278
279
280
281 === 2.3.4 Soil Temperature ===
282
283 Get Soil Temperature 
284
285
286 **Example**:
287
288 If payload is: **0105H**:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
289
290 If payload is: **FF3FH** :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
291
292
293
294 === 2.3.5 Interrupt Pin ===
295
296 This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
297
298
299 **Example:**
300
301 0x00: Normal uplink packet.
302
303 0x01: Interrupt Uplink Packet.
304
305
306
307 === 2.3.6 Message Type ===
308
309 For a normal uplink payload, the message type is always 0x01.
310
311 Valid Message Type:
312
313
314 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
315 |**Message Type Code**|**Description**|**Payload**
316 |0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
317 |0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
318 |0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
319
320
321
322 === 2.3.7 Decode payload in The Things Network ===
323
324 While using TTN network, you can add the payload format to decode the payload.
325
326
327 [[image:1654592762713-715.png]]
328
329 (((
330 The payload decoder function for TTN is here:
331 )))
332
333 (((
334 LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
335 )))
336
337
338
339 == 2.4 Uplink Interval ==
340
341 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
342
343
344
345 == 2.5 ​Show Data in DataCake IoT Server ==
346
347 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
348
349
350 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
351
352 (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
353
354
355 [[image:1654592790040-760.png]]
356
357
358 [[image:1654592800389-571.png]]
359
360
361 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
362
363 (% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**
364
365 [[image:1654592819047-535.png]]
366
367
368
369 [[image:1654592833877-762.png]]
370
371
372 [[image:1654592856403-259.png]]
373
374
375 (% style="color:blue" %)**Step 5**(%%)**: add payload decode**
376
377 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
378
379
380 [[image:1654592878525-845.png]]
381
382 [[image:1654592892967-474.png]]
383
384
385 [[image:1654592905354-123.png]]
386
387
388 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
389
390
391 [[image:1654592917530-261.png]]
392
393
394
395 == 2.6 Installation and Maintain ==
396
397 === 2.6.1 Before measurement ===
398
399 (((
400 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
401 )))
402
403
404
405 === 2.6.2 Measurement ===
406
407
408 (% style="color:#4f81bd" %)**Measurement the soil surface:**
409
410 [[image:1654592946732-634.png]]
411
412 Choose the proper measuring position. Split the surface soil according to the measured deep.
413
414 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
415
416 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
417
418 Put soil over the probe after insert. And start to measure.
419
420
421 (% style="color:#4f81bd" %)**Measurement inside soil:**
422
423 Dig a hole with diameter > 20CM.
424
425 Insert the probe inside, method like measure the surface.
426
427
428
429 === 2.6.3 Maintain Probe ===
430
431 1. (((
432 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
433 )))
434 1. (((
435 After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
436 )))
437 1. (((
438 Probe reference electrode is also no strong, need to avoid strong force or hitting.
439 )))
440 1. (((
441 User should keep reference electrode wet while not use.
442 )))
443 1. (((
444 Avoid the probes to touch oily matter. Which will cause issue in accuracy.
445 )))
446 1. (((
447 The probe is IP68 can be put in water.
448
449
450
451 )))
452
453 == 2.7 Calibration ==
454
455 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
456
457 After stable, user can use below command to calibrate.
458
459 [[image:image-20220607171149-4.png]]
460
461
462 (% style="color:#037691" %)**Calibration Payload**
463
464 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
465 |(((
466 **Size**
467
468 **(bytes)**
469 )))|**1**|**1**|**1**|**7**|**1**
470 |**Value**|(((
471 PH4
472
473 Calibrate value
474 )))|PH6.86 Calibrate value|(((
475 PH9.18
476
477 Calibrate value
478 )))|Reserve|(((
479 [[Message Type>>path:#H2.3.6MessageType]]
480
481 Always 0x03
482 )))
483
484 User can also send 0x14 downlink command to poll the current calibration payload.
485
486 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/image-20220607145603-4.png?rev=1.1||alt="image-20220607145603-4.png"]]
487
488 * Reply to the confirmation package: 14 01
489 * Reply to non-confirmed packet: 14 00
490
491 == 2.8 Frequency Plans ==
492
493 (((
494 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
495 )))
496
497
498 === 2.8.1 EU863-870 (EU868) ===
499
500 (% style="color:blue" %)**Uplink:**
501
502 868.1 - SF7BW125 to SF12BW125
503
504 868.3 - SF7BW125 to SF12BW125 and SF7BW250
505
506 868.5 - SF7BW125 to SF12BW125
507
508 867.1 - SF7BW125 to SF12BW125
509
510 867.3 - SF7BW125 to SF12BW125
511
512 867.5 - SF7BW125 to SF12BW125
513
514 867.7 - SF7BW125 to SF12BW125
515
516 867.9 - SF7BW125 to SF12BW125
517
518 868.8 - FSK
519
520
521 (% style="color:blue" %)**Downlink:**
522
523 Uplink channels 1-9 (RX1)
524
525 869.525 - SF9BW125 (RX2 downlink only)
526
527
528
529 === 2.8.2 US902-928(US915) ===
530
531 (((
532 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
533 )))
534
535 (((
536 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
537 )))
538
539 (((
540 After Join success, the end node will switch to the correct sub band by:
541 )))
542
543 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
544 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
545
546 === 2.8.3 CN470-510 (CN470) ===
547
548 Used in China, Default use CHE=1
549
550 (% style="color:blue" %)**Uplink:**
551
552 486.3 - SF7BW125 to SF12BW125
553
554 486.5 - SF7BW125 to SF12BW125
555
556 486.7 - SF7BW125 to SF12BW125
557
558 486.9 - SF7BW125 to SF12BW125
559
560 487.1 - SF7BW125 to SF12BW125
561
562 487.3 - SF7BW125 to SF12BW125
563
564 487.5 - SF7BW125 to SF12BW125
565
566 487.7 - SF7BW125 to SF12BW125
567
568
569 (% style="color:blue" %)**Downlink:**
570
571 506.7 - SF7BW125 to SF12BW125
572
573 506.9 - SF7BW125 to SF12BW125
574
575 507.1 - SF7BW125 to SF12BW125
576
577 507.3 - SF7BW125 to SF12BW125
578
579 507.5 - SF7BW125 to SF12BW125
580
581 507.7 - SF7BW125 to SF12BW125
582
583 507.9 - SF7BW125 to SF12BW125
584
585 508.1 - SF7BW125 to SF12BW125
586
587 505.3 - SF12BW125 (RX2 downlink only)
588
589
590
591 === 2.8.4 AU915-928(AU915) ===
592
593 (((
594 Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
595 )))
596
597 (((
598 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
599 )))
600
601 (((
602
603 )))
604
605 (((
606 After Join success, the end node will switch to the correct sub band by:
607 )))
608
609 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
610 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
611
612 === 2.8.5 AS920-923 & AS923-925 (AS923) ===
613
614 (% style="color:blue" %)**Default Uplink channel:**
615
616 923.2 - SF7BW125 to SF10BW125
617
618 923.4 - SF7BW125 to SF10BW125
619
620
621 (% style="color:blue" %)**Additional Uplink Channel**:
622
623 (OTAA mode, channel added by JoinAccept message)
624
625
626 (% style="color:blue" %)**AS920~~AS923 for Japan, Malaysia, Singapore**:
627
628 922.2 - SF7BW125 to SF10BW125
629
630 922.4 - SF7BW125 to SF10BW125
631
632 922.6 - SF7BW125 to SF10BW125
633
634 922.8 - SF7BW125 to SF10BW125
635
636 923.0 - SF7BW125 to SF10BW125
637
638 922.0 - SF7BW125 to SF10BW125
639
640
641 (% style="color:blue" %)**AS923 ~~ AS925 for Brunei, Cambodia, Hong Kong, Indonesia, Laos, Taiwan, Thailand, Vietnam**:
642
643 923.6 - SF7BW125 to SF10BW125
644
645 923.8 - SF7BW125 to SF10BW125
646
647 924.0 - SF7BW125 to SF10BW125
648
649 924.2 - SF7BW125 to SF10BW125
650
651 924.4 - SF7BW125 to SF10BW125
652
653 924.6 - SF7BW125 to SF10BW125
654
655
656 (% style="color:blue" %)**Downlink:**
657
658 Uplink channels 1-8 (RX1)
659
660 923.2 - SF10BW125 (RX2)
661
662
663
664 === 2.8.6 KR920-923 (KR920) ===
665
666 (% style="color:blue" %)**Default channel:**
667
668 922.1 - SF7BW125 to SF12BW125
669
670 922.3 - SF7BW125 to SF12BW125
671
672 922.5 - SF7BW125 to SF12BW125
673
674
675 (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
676
677 922.1 - SF7BW125 to SF12BW125
678
679 922.3 - SF7BW125 to SF12BW125
680
681 922.5 - SF7BW125 to SF12BW125
682
683 922.7 - SF7BW125 to SF12BW125
684
685 922.9 - SF7BW125 to SF12BW125
686
687 923.1 - SF7BW125 to SF12BW125
688
689 923.3 - SF7BW125 to SF12BW125
690
691
692 (% style="color:blue" %)**Downlink:**
693
694 Uplink channels 1-7(RX1)
695
696 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
697
698
699
700 === 2.8.7 IN865-867 (IN865) ===
701
702 (% style="color:blue" %)**Uplink:**
703
704 865.0625 - SF7BW125 to SF12BW125
705
706 865.4025 - SF7BW125 to SF12BW125
707
708 865.9850 - SF7BW125 to SF12BW125
709
710
711 (% style="color:blue" %)**Downlink:**
712
713 Uplink channels 1-3 (RX1)
714
715 866.550 - SF10BW125 (RX2)
716
717
718
719 == 2.9 LED Indicator ==
720
721 The LSPH01 has an internal LED which is to show the status of different state.
722
723 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
724 * Blink once when device transmit a packet.
725
726 == 2.10 ​Firmware Change Log ==
727
728
729 **Firmware download link:**
730
731 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
732
733
734 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
735
736
737
738 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
739
740 Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
741
742 * AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
743 * LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
744
745 There are two kinds of commands to configure LSPH01, they are:
746
747 * (% style="color:#4f81bd" %)** General Commands**.
748
749 These commands are to configure:
750
751 * General system settings like: uplink interval.
752 * LoRaWAN protocol & radio related command.
753
754 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
755
756
757 * (% style="color:#4f81bd" %)** Commands special design for LSPH01**
758
759 These commands only valid for LSPH01, as below:
760
761
762
763 == 3.1 Set Transmit Interval Time ==
764
765 Feature: Change LoRaWAN End Node Transmit Interval.
766
767 (% style="color:#037691" %)**AT Command: AT+TDC**
768
769
770 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
771 |(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
772 |(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
773 30000
774
775 OK
776
777 the interval is 30000ms = 30s
778 )))
779 |(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
780 OK
781
782 Set transmit interval to 60000ms = 60 seconds
783 )))
784
785 (% style="color:#037691" %)**Downlink Command: 0x01**
786
787 Format: Command Code (0x01) followed by 3 bytes time value.
788
789 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
790
791 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
792 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
793
794 == 3.2 Set Interrupt Mode ==
795
796 Feature, Set Interrupt mode for GPIO_EXIT.
797
798 (% style="color:#037691" %)**AT Command: AT+INTMOD**
799
800 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/image-20220607153759-6.png?rev=1.1||alt="image-20220607153759-6.png"]]
801
802
803 (% style="color:#037691" %)**Downlink Command: 0x06**
804
805 Format: Command Code (0x06) followed by 3 bytes.
806
807 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
808
809 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
810 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
811
812 == 3.3 Calibrate Sensor ==
813
814 Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
815
816
817
818 == 3.4 Get Firmware Version Info ==
819
820 Feature: use downlink to get firmware version.
821
822 (% style="color:#037691" %)**Downlink Command: 0x26**
823
824 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/image-20220607154718-7.png?rev=1.1||alt="image-20220607154718-7.png"]]
825
826 * Reply to the confirmation package: 26 01
827 * Reply to non-confirmed packet: 26 00
828
829 Device will send an uplink after got this downlink command. With below payload:
830
831 Configures info payload:
832
833 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
834 |=(((
835 **Size(bytes)**
836 )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
837 |**Value**|Software Type|(((
838 Frequency
839
840 Band
841 )))|Sub-band|(((
842 Firmware
843
844 Version
845 )))|Sensor Type|Reserve|(((
846 [[Message Type>>path:#H2.3.6MessageType]]
847 Always 0x02
848 )))
849
850 **Software Type**: Always 0x03 for LSPH01
851
852
853 **Frequency Band**:
854
855 *0x01: EU868
856
857 *0x02: US915
858
859 *0x03: IN865
860
861 *0x04: AU915
862
863 *0x05: KZ865
864
865 *0x06: RU864
866
867 *0x07: AS923
868
869 *0x08: AS923-1
870
871 *0x09: AS923-2
872
873 *0xa0: AS923-3
874
875
876 **Sub-Band**: value 0x00 ~~ 0x08
877
878
879 **Firmware Version**: 0x0100, Means: v1.0.0 version
880
881
882 **Sensor Type**:
883
884 0x01: LSE01
885
886 0x02: LDDS75
887
888 0x03: LDDS20
889
890 0x04: LLMS01
891
892 0x05: LSPH01
893
894 0x06: LSNPK01
895
896 0x07: LDDS12
897
898
899
900 = 4. Battery & How to replace =
901
902 == 4.1 Battery Type ==
903
904 (((
905 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
906 )))
907
908 (((
909 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
910 )))
911
912 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654588469844-778.png?rev=1.1||alt="1654588469844-778.png"]]
913
914
915 Minimum Working Voltage for the LSPH01:
916
917 LSPH01:  2.45v ~~ 3.6v
918
919
920
921 == 4.2 Replace Battery ==
922
923 (((
924 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
925 )))
926
927 (((
928 And make sure the positive and negative pins match.
929 )))
930
931
932
933 == 4.3 Power Consumption Analyze ==
934
935 (((
936 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
937 )))
938
939 (((
940 Instruction to use as below:
941 )))
942
943
944 **Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
945
946 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
947
948
949 **Step 2**: Open it and choose
950
951 * Product Model
952 * Uplink Interval
953 * Working Mode
954
955 And the Life expectation in difference case will be shown on the right.
956
957 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654588577573-122.png?rev=1.1||alt="1654588577573-122.png"]]
958
959
960 The battery related documents as below:
961
962 * (((
963 [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
964 )))
965 * (((
966 [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
967 )))
968 * (((
969 [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
970 )))
971
972 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/image-20220607155856-8.png?rev=1.1||alt="image-20220607155856-8.png"]]
973
974
975
976 === 4.3.1 ​Battery Note ===
977
978 (((
979 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
980 )))
981
982
983
984 === ​4.3.2 Replace the battery ===
985
986 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
987
988 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
989
990
991
992 = 5. Use AT Command =
993
994 == 5.1 Access AT Commands ==
995
996 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
997
998 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654589001411-343.png?rev=1.1||alt="1654589001411-343.png"]]
999
1000 **Connection:**
1001
1002 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
1003
1004 (% style="background-color:yellow" %)** USB TTL TXD  <~-~-~-~-> UART_RXD**
1005
1006 (% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
1007
1008
1009 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
1010
1011
1012 [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654589062541-567.png?rev=1.1||alt="1654589062541-567.png"]]
1013
1014 Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1015
1016
1017
1018 = 6. FAQ =
1019
1020 == 6.1 How to change the LoRa Frequency Bands/Region ==
1021
1022 You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1023 When downloading the images, choose the required image file for download. ​
1024
1025
1026
1027 = 7. Trouble Shooting =
1028
1029 == 7.1 AT Commands input doesn’t work ==
1030
1031 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1032
1033
1034
1035 = 8. Order Info =
1036
1037 Part Number: (% style="color:blue" %)**LSPH01-XX**
1038
1039
1040 (% style="color:blue" %)**XX**(%%): The default frequency band
1041
1042 * (% style="color:red" %)**AS923**(%%):  LoRaWAN AS923 band
1043 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1044 * (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1045 * (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1046 * (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1047 * (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1048 * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1049 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1050
1051 = 9. ​Packing Info =
1052
1053
1054 **Package Includes**:
1055
1056 * LSPH01 LoRaWAN Soil Ph Sensor x 1
1057
1058 **Dimension and weight**:
1059
1060 * Device Size: cm
1061 * Device Weight: g
1062 * Package Size / pcs : cm
1063 * Weight / pcs : g
1064
1065 = 10. ​Support =
1066
1067 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1068 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].