Show last authors
1
2
3
4
5
6 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
7
8
9
10
11
12
13
14 1. Introduction
15 11. What is LWL02 LoRaWAN Water Leak Sensor
16
17 The Dragino LWL02 is a LoRaWAN Water Sensor. When there is water between the two metal probes, LWL02 indicates a water leak event and uplink to IoT server via LoRaWAN network.
18
19
20 LWL02 is powered by 2 x AAA batteries and target for long time use, these two batteries can provide about 16,000 ~~ 70,000 uplink packets, which result in 2 ~~ 10 years battery life. After battery running out, user can easily open the enclosure and replace with 2 common AAA batteries.
21
22
23 The LWL02 will send periodically data every day as well as for each water leak event. It also counts the water leak times and calculate last water leak duration. User can also disable the uplink for each water leak event, instead, device can count each event and uplink periodically.
24
25
26 Each LWL02 is pre-load with a set of unique keys for LoRaWAN registration, register these keys to
27
28 LoRaWAN server and it will auto connect after power on. [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image002.png]]
29
30
31
32
33 *
34 *1. Features
35 * LoRaWAN Class A v1.0.3
36 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
37 * SX1262 LoRa Core
38 * Water Leak detect
39 * 2 x AAA LR03 Batteries
40 * AT Commands to change parameters
41 * Uplink on periodically and open/close action
42 * Remote configure parameters via LoRa Downlink
43 * Firmware upgradable via program port
44
45 *
46 *1. Applications
47 * Smart Buildings & Home Automation
48 * Logistics and Supply Chain Management
49 * Smart Metering
50 * Smart Agriculture
51 * Smart Cities
52 * Smart Factory
53
54 1.
55 11. Dimension
56
57 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image003.png]]
58
59 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.png]]
60
61
62 1.
63 11. Firmware Change log
64
65 LWL02 use the same firmware as LDS01.
66
67 [[LWL02 Image files – Download link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
68
69
70
71
72 1. Power ON LWL02
73
74 When receive the LWL02, please open the enclosure and add 2 x AAA batteries to power it. The [[LED>>path:#LED]] will blink when device is powered.
75
76
77
78 1. How to install LWL02
79
80 When install the LWL02 on wall. Please install as below so the water leak probe will be soak in water for water detect purpose. The LWL02 main body is not water proof. Please don’t let water go inside the LWL02 main body.
81
82
83 |(((
84 50cm
85
86
87 )))
88
89 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image005.png]]
90
91
92
93
94
95
96 1. Operation Mode
97 11. How it works?
98
99 The LWL02 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and [[power on>>path:#Power_on]] the LWL02. It will auto join the network via OTAA.
100
101
102 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>path:#AT_Command]] to set the keys in the devices.
103
104
105 1.
106 11. Example to join LoRaWAN network
107
108 Here shows an example for how to join the [[TTN V3 Network>>url:https://eu1.cloud.thethings.network/]]. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
109
110 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image006.png]]
111
112
113
114 The LWL02 has water leak detect probe as above. When there is water between these two detect probe, they will be short and generate the water leak event. and send the status to LoRaWAN server. The LWL02 will uplink two type of messages to the server.
115
116 * A keep-alive message which send once per day.
117 * An emergency event message when detect a water leak. ([[Alarm event can be disabled>>path:#Alarm]])
118 * A periodically update at every 10 minutes when in water leak.
119 * A message when switch from water leak to none water leak. ([[Alarm event can be disabled>>path:#Alarm]])
120
121
122 The LG308 is already set to connect to [[TTN V3 network >>url:https://eu1.cloud.thethings.network/]]. What we need to now is only configure the TTN V3:
123
124 **Step 1**: Create a device in TTN V3 with the OTAA keys from LWL02.
125
126 Each LWL02 is shipped with a sticker with unique device EUI:
127
128 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]]
129
130
131
132
133 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
134
135 Add APP EUI in the application.
136
137 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image008.png]]
138
139
140 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image009.png]]
141
142 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image010.png]]
143
144
145 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image011.png]]
146
147
148
149
150
151
152
153 Add APP KEY and DEV EUI
154
155 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image012.png]]
156
157 **Step 2**: [[Power on>>path:#Power_on]] LWL02 and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
158
159 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image013.png]]
160
161
162 1.
163 11. Uplink Payload
164
165 Uplink Payload total 9 bytes.
166
167
168 |**Size(bytes)**|**2**|**1**|**3**|**3**
169 |value|Status&BAT|(((
170 MOD
171
172 Always:0x02
173 )))|Total water leak events|(((
174 Last water leak
175
176 duration (unit: min)
177 )))
178
179 Example:
180
181 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image014.png]]
182
183
184 Example Payload Decoder in TTN V3:
185
186 [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Payload/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Payload/]]
187
188
189
190
191 1.
192 11. Downlink Payload
193
194 |**Downlink Control Type**|**Type Code**|**Downlink payload size(bytes)**
195 |TDC (Transmit Time Interval—Keep Alive Interval)|0x01|4
196 |RESET|0x04|2
197 |[[Set confirmed mode>>path:#code05]]|0x05|2
198 |[[Clear Counting>>path:#codeA6]]|0xA6|2
199 |[[Enable/Disable Alarm>>path:#code70]]|0xA7|2
200 |[[Control ADR/DR>>path:#codeA8]]|0xA8|3
201 |[[Set Alarm Timeout>>path:#Alarm_Timeout]]|0xA9|4
202
203
204
205 Example Downlink payload setting in TTN V3:
206
207 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image015.png]]
208
209
210 **Type Code 0x01**
211
212 If the payload=0100003C, means to control the LWL02’s Keep Alive interval to 0x00003C=60(S)
213
214
215 **Type Code 0x04**
216
217 If payload = 0x04FF, it will reset the LWL02.
218
219
220 **Type Code 0x05**
221
222 0x05 00: Set uplink to LoRaWAN unconfirmed mode
223
224 0x05 01: Set uplink to LoRaWAN confirmed mode
225
226
227 **Type Code 0xA6**
228
229 Example: 0xA601: Clear Counting
230 For LWL02: reset both count number and time.
231
232
233 **Type Code 0xA7**
234
235 0xA7 01 : Equal to AT+DISALARM=1
236
237 0xA7 00 : Equal to AT+DISALARM=0
238
239
240 **Type Code 0xA8**
241
242 Format: 0xA8 aa bb
243
244 aa: 1: Enable ADR; 0: Disable ADR (Same as AT+CADR command)
245
246 bb: set DR (Same as AT+CDATARATE ,only valid after ADR=0)
247
248 Example: 0x A8 00 02 : Set ADR=0 and DR=1
249
250
251 **Type Code 0xA9**
252
253 See [[Alarm Base Timeout>>path:#Alarm_Timeout]] for detail.
254
255
256
257 1.
258 11. Integrate with Datacake
259
260 Datacake provides a human friendly interface to show the sensor data, once we have data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
261
262
263 Step 1: Be sure that your device is programmed and properly connected to the network at this time.
264
265 Step 2: To configure the Application to forward data to Datacake you will need to add integration. To add the Datacake integration, perform the following steps:
266
267
268 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image016.png]]
269
270
271 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image017.png]]
272
273
274 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]
275
276
277
278 Step 3: Create an account or log in Datacake.
279
280 Step 4: Search LWL02 and add DevEUI.
281
282 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]]
283
284
285 1.
286 11. Alarm Base on Timeout
287
288 LWL02 can monitor the timeout for a status change, this feature can be used to monitor some event such as open fridge too long etc.
289
290
291 User configure this feature by using:
292
293
294 **AT Command** to configure:
295
296 * AT+TTRIG=1,30   à When status change from close to open, and device keep in open
297
298 status for more than 30 seconds. LWL02 will send an uplink packet, the Alarm bit (the lowest bit of 10^^th^^ byte of payload) on this uplink packet is set to 1.
299
300 * AT+TTIG=0,0 à Default Value, disable timeout Alarm.
301
302 **Downlink Command** to configure:
303
304 Command: 0xA9 aa bb cc
305
306 A9: Command Type Code
307
308 aa: status to be monitor
309
310 bb cc: timeout.
311
312
313 If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30
314
315 Or
316
317 0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm.
318
319
320
321
322 1.
323 11. LEDs
324
325 |**Action**|**LED behavior**
326 |Power On|**GREEN on 1s, RED on 1s, BLUE on 1s**
327 |Joined successful|**GRENN LED **on 5s
328 |Send an uplink message|**GREEN LED** blinks once
329 |Got a downlink message|**BLUE LED** blinks once
330
331
332
333 1. Battery & How to replace
334 11. Battery Type and replace
335
336 LWL02 is equipped with 2 x AAA LR03 batteries. If the batteries running low(see 2.1v in the platform). User can buy generic AAA battery and replace it. Note:
337
338 1. The LWL02 doesn’t have any screw, use can use nail to open it by the middle.
339 1. Make sure the direction is correct when install the AAA batteries.
340
341 **Important Notice: Make sure use new AAA LR03 battery and the battery doesn’t have broken surface.**
342
343
344 Example of AAA LR03 batter:
345
346 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]
347
348
349
350
351 1.
352 11. Power Consumption Analyze
353
354 Dragino battery powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimate battery life:
355
356 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]]
357
358
359
360 1. Use AT Command
361 11. Access AT Command
362
363 LWL02 supports AT Command set. User can use a USB to TTL adapter to configure LWL02 via use AT command, as below.
364
365 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]]
366
367 USB to TTL <- -> LWL02
368
369 RX <- -> TX
370
371 TX <- -> RX
372
373 GND <- -> GND
374
375
376 In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **115200** to access to access serial console of LWL02. Below is the output for reference:
377
378 The AT Access password is **123456**.
379
380 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
381
382 Each AT Command need to add an ENTER at the end before send.
383
384
385 When entering the first command, the RED LED will on and user can now input AT Commands. After input all needed AT Commands, please input AT+CLPM=1 to set the device to work in Low Power mode and RED LED will be off.
386
387
388 More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/]]
389
390
391
392
393 = 7. FAQ =
394
395 == 7.1 How to upgrade the image? ==
396
397 User can upgrade the of LWL02 for bug fix, new features, or change working region. The upgrade instruction is here:  [[Firmware Upgrade Instruction>>Firmware Upgrade Instruction for STM32 base products]]
398
399
400
401
402 == 7.2 How to change the LoRa Frequency Bands/Region? ==
403
404 If user has for example US915 frequency and want to change it to AS923 frequency. User can follow the introduction for [[how to upgrade image>>||anchor="H7.1Howtoupgradetheimage"]]. When download the images, choose the required image file for download.
405
406
407
408
409 == 7.3 Can I disable uplink for each event to save battery life? ==
410
411 Yes, User can use below method to disable this:
412
413 (% style="color:#4f81bd" %)**via AT Command**:
414
415 AT+DISALARM=1, End node will only send packet in TDC time.
416
417 AT+DISALARM=0, End node will send packet in TDC time or status change for door sensor. 
418
419 (% style="color:#4f81bd" %)**via LoRaWAN downlink Command**:
420
421 0xA701 : Equal to AT+DISALARM=1
422
423 0xA700 : Equal to AT+DISALARM=0
424
425
426
427
428 = 8. Order Info =
429
430 **Part Number: (% style="color:blue" %)LWL02-XXX(%%)**
431
432 (% style="color:blue" %)**XXX:**
433
434 * (% style="color:red" %)**EU433**(%%): frequency  bands EU433
435 * (% style="color:red" %)**EU868**(%%): frequency  bands EU868
436 * (% style="color:red" %)**KR920**(%%): frequency  bands KR920
437 * (% style="color:red" %)**CN470**(%%): frequency bands CN470
438 * (% style="color:red" %)**AS923**(%%): frequency  bands AS923
439 * (% style="color:red" %)**AU915**(%%): frequency bands AU915
440 * (% style="color:red" %)**US915**(%%): frequency bands  US915
441 * (% style="color:red" %)**IN865**(%%):  frequency bands  IN865
442 * (% style="color:red" %)**CN779**(%%): frequency bands CN779
443
444 = 9. Packing Info =
445
446
447 **Package Includes**:
448
449 * LWL02 x 1
450
451 = 10.Support =
452
453 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
454 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
455
456
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0