From version < 159.1 >
edited by Edwin Chen
on 2022/12/28 17:10
To version < 161.1 >
edited by Bei Jinggeng
on 2023/06/09 18:08
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Bei
Content
... ... @@ -52,7 +52,6 @@
52 52  * Firmware upgradable via UART interface
53 53  * Open Source Mobile App for LoRaWAN signal detect and GPS tracking.
54 54  
55 -
56 56  == 1.3  Specification ==
57 57  
58 58  
... ... @@ -72,7 +72,6 @@
72 72  * LoRa Tx Current: <90 mA at +17 dBm, 108 mA at +22 dBm
73 73  * LoRa Rx current: <9 mA
74 74  
75 -
76 76  == 1.4  Pin Mapping & LED ==
77 77  
78 78  
... ... @@ -400,11 +400,42 @@
400 400  
401 401  Just use the yellow jumper cap to short the BOOT corner and the RX corner, and then press the RESET button (without the jumper cap, you can directly short the BOOT corner and the RX corner with a wire to achieve the same effect).
402 402  
403 -Notice: If upgrade via USB hub is not sucessful. try to connect to PC directly.
401 +(% style="color:red" %)**Notice: If upgrade via USB hub is not sucessful. try to connect to PC directly.**
404 404  
405 405  [[image:image-20220723150132-2.png]]
406 406  
405 +==== ** Open the Upgrade tool (Tremo Programmer) in PC and Upgrade** ====
407 407  
407 +**1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]**
408 +
409 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602103227-6.png?rev=1.1||alt="image-20220602103227-6.png"]]
410 +
411 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602103357-7.png?rev=1.1||alt="image-20220602103357-7.png"]]
412 +
413 +**2.  Select the COM port corresponding to USB TTL**
414 +
415 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602103844-8.png?rev=1.1||alt="image-20220602103844-8.png"]]
416 +
417 +**3.  Select the bin file to burn**
418 +
419 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104144-9.png?rev=1.1||alt="image-20220602104144-9.png"]]
420 +
421 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104251-10.png?rev=1.1||alt="image-20220602104251-10.png"]]
422 +
423 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104402-11.png?rev=1.1||alt="image-20220602104402-11.png"]]
424 +
425 +**4.  Click to start the download**
426 +
427 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104923-13.png?rev=1.1||alt="image-20220602104923-13.png"]]
428 +
429 +**5.  Check update process**
430 +
431 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104948-14.png?rev=1.1||alt="image-20220602104948-14.png"]]
432 +
433 +**The following picture shows that the burning is successful**
434 +
435 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602105251-15.png?rev=1.1||alt="image-20220602105251-15.png"]]
436 +
408 408  = 2.  FAQ =
409 409  
410 410  == 2.1  How to Compile Source Code for LA66? ==
... ... @@ -419,6 +419,13 @@
419 419  Instruction for LA66 Peer to Peer firmware :[[ Instruction >>doc:Main.User Manual for LoRaWAN End Nodes.LA66 LoRaWAN Shield User Manual.Instruction for LA66 Peer to Peer firmware.WebHome]]
420 420  
421 421  
451 +== 2.3 My device keeps showing invalid credentials, the device goes into low power mode ==
452 +
453 +Set the AT+COMMAND:
454 +
455 +AT+UUID=666666666666
456 +
457 +
422 422  = 3.  Order Info =
423 423  
424 424  
... ... @@ -437,7 +437,6 @@
437 437  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
438 438  * (% style="color:red" %)**PP**(%%):  Peer to Peer LoRa Protocol
439 439  
440 -
441 441  = 4.  Reference =
442 442  
443 443  
... ... @@ -444,7 +444,6 @@
444 444  * Hardware Design File for LA66 USB LoRaWAN Adapter : [[Download>>https://www.dropbox.com/sh/a3wbmdcvqjxaqw5/AADZfvAiykJTK624RgMquH86a?dl=0]]
445 445  * Mobile Phone App Source Code: [[Download>>https://github.com/dragino/LA66_Mobile_App]].
446 446  
447 -
448 448  = 5.  FCC Statement =
449 449  
450 450  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0