<
From version < 158.3 >
edited by Xiaoling
on 2022/12/13 17:34
To version < 161.1 >
edited by Bei Jinggeng
on 2023/06/09 18:08
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -52,8 +52,6 @@
52 52  * Firmware upgradable via UART interface
53 53  * Open Source Mobile App for LoRaWAN signal detect and GPS tracking.
54 54  
55 -
56 -
57 57  == 1.3  Specification ==
58 58  
59 59  
... ... @@ -73,8 +73,6 @@
73 73  * LoRa Tx Current: <90 mA at +17 dBm, 108 mA at +22 dBm
74 74  * LoRa Rx current: <9 mA
75 75  
76 -
77 -
78 78  == 1.4  Pin Mapping & LED ==
79 79  
80 80  
... ... @@ -402,10 +402,42 @@
402 402  
403 403  Just use the yellow jumper cap to short the BOOT corner and the RX corner, and then press the RESET button (without the jumper cap, you can directly short the BOOT corner and the RX corner with a wire to achieve the same effect).
404 404  
401 +(% style="color:red" %)**Notice: If upgrade via USB hub is not sucessful. try to connect to PC directly.**
405 405  
406 406  [[image:image-20220723150132-2.png]]
407 407  
405 +==== ** Open the Upgrade tool (Tremo Programmer) in PC and Upgrade** ====
408 408  
407 +**1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]**
408 +
409 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602103227-6.png?rev=1.1||alt="image-20220602103227-6.png"]]
410 +
411 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602103357-7.png?rev=1.1||alt="image-20220602103357-7.png"]]
412 +
413 +**2.  Select the COM port corresponding to USB TTL**
414 +
415 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602103844-8.png?rev=1.1||alt="image-20220602103844-8.png"]]
416 +
417 +**3.  Select the bin file to burn**
418 +
419 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104144-9.png?rev=1.1||alt="image-20220602104144-9.png"]]
420 +
421 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104251-10.png?rev=1.1||alt="image-20220602104251-10.png"]]
422 +
423 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104402-11.png?rev=1.1||alt="image-20220602104402-11.png"]]
424 +
425 +**4.  Click to start the download**
426 +
427 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104923-13.png?rev=1.1||alt="image-20220602104923-13.png"]]
428 +
429 +**5.  Check update process**
430 +
431 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602104948-14.png?rev=1.1||alt="image-20220602104948-14.png"]]
432 +
433 +**The following picture shows that the burning is successful**
434 +
435 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602105251-15.png?rev=1.1||alt="image-20220602105251-15.png"]]
436 +
409 409  = 2.  FAQ =
410 410  
411 411  == 2.1  How to Compile Source Code for LA66? ==
... ... @@ -420,6 +420,13 @@
420 420  Instruction for LA66 Peer to Peer firmware :[[ Instruction >>doc:Main.User Manual for LoRaWAN End Nodes.LA66 LoRaWAN Shield User Manual.Instruction for LA66 Peer to Peer firmware.WebHome]]
421 421  
422 422  
451 +== 2.3 My device keeps showing invalid credentials, the device goes into low power mode ==
452 +
453 +Set the AT+COMMAND:
454 +
455 +AT+UUID=666666666666
456 +
457 +
423 423  = 3.  Order Info =
424 424  
425 425  
... ... @@ -438,8 +438,6 @@
438 438  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
439 439  * (% style="color:red" %)**PP**(%%):  Peer to Peer LoRa Protocol
440 440  
441 -
442 -
443 443  = 4.  Reference =
444 444  
445 445  
... ... @@ -446,8 +446,6 @@
446 446  * Hardware Design File for LA66 USB LoRaWAN Adapter : [[Download>>https://www.dropbox.com/sh/a3wbmdcvqjxaqw5/AADZfvAiykJTK624RgMquH86a?dl=0]]
447 447  * Mobile Phone App Source Code: [[Download>>https://github.com/dragino/LA66_Mobile_App]].
448 448  
449 -
450 -
451 451  = 5.  FCC Statement =
452 452  
453 453  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0