... ... @@ -54,6 +54,161 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 += Configure GroPoint Air via AT Command or LoRaWAN Downlink =
58 +
59 +Use can configure GroPoint Air via AT Command or LoRaWAN Downlink.
60 +
61 +* (((
62 +AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
63 +)))
64 +* (((
65 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
66 +)))
67 +
68 +There are two kinds of commands to configure GroPoint, they are:
69 +
70 +* (((
71 +**~ General Commands**.
72 +)))
73 +
74 +These commands are to configure:
75 +
76 +* (((
77 +General system settings like: uplink interval.
78 +)))
79 +* (((
80 +LoRaWAN protocol & radio-related command.
81 +)))
82 +
83 +They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
84 +
85 +
86 +* (((
87 +**~ Commands special design for LLMS01**
88 +)))
89 +
90 +These commands only valid for LLMS01, as below:
91 +
92 +== 3.1 Set Transmit Interval Time ==
93 +
94 +Feature: Change LoRaWAN End Node Transmit Interval.
95 +
96 +**AT Command: AT+TDC**
97 +
98 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171554-8.png?rev=1.1||alt="image-20220607171554-8.png"]]
99 +
100 +**Downlink Command: 0x01**
101 +
102 +Format: Command Code (0x01) followed by 3 bytes time value.
103 +
104 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
105 +
106 +* (((
107 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
108 +)))
109 +* (((
110 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
111 +
112 +
113 +)))
114 +
115 +== 3.2 Set Interrupt Mode  (是否存在) ==
116 +
117 +Feature, Set Interrupt mode for GPIO_EXIT.
118 +
119 +**AT Command: AT+INTMOD**
120 +
121 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171716-9.png?rev=1.1||alt="image-20220607171716-9.png"]]
122 +
123 +**Downlink Command: 0x06**
124 +
125 +Format: Command Code (0x06) followed by 3 bytes.
126 +
127 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
128 +
129 +* (((
130 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
131 +)))
132 +* (((
133 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
134 +)))
135 +
136 +
137 +== 3.3 Get Firmware Version Info ~-~--(是否存在) ==
138 +
139 +Feature: use downlink to get firmware version.
140 +
141 +**Downlink Command: 0x26**
142 +
143 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171917-10.png?rev=1.1||alt="image-20220607171917-10.png"]]
144 +
145 +* Reply to the confirmation package: 26 01
146 +* Reply to non-confirmed packet: 26 00
147 +
148 +Device will send an uplink after got this downlink command. With below payload:
149 +
150 +Configures info payload:
151 +
152 +|=(((
153 +**Size(bytes)**
154 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
155 +|**Value**|Software Type|(((
156 +Frequency
157 +
158 +Band
159 +)))|Sub-band|(((
160 +Firmware
161 +
162 +Version
163 +)))|Sensor Type|Reserve|(((
164 +[[Message Type>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H2.3.6MessageType]]
165 +Always 0x02
166 +)))
167 +
168 +**Software Type**: Always 0x03 for LLMS01
169 +
170 +**Frequency Band**:
171 +
172 +*0x01: EU868
173 +
174 +*0x02: US915
175 +
176 +*0x03: IN865
177 +
178 +*0x04: AU915
179 +
180 +*0x05: KZ865
181 +
182 +*0x06: RU864
183 +
184 +*0x07: AS923
185 +
186 +*0x08: AS923-1
187 +
188 +*0x09: AS923-2
189 +
190 +*0xa0: AS923-3
191 +
192 +**Sub-Band**: value 0x00 ~~ 0x08
193 +
194 +**Firmware Version**: 0x0100, Means: v1.0.0 version
195 +
196 +**Sensor Type**:
197 +
198 +0x01: LSE01
199 +
200 +0x02: LDDS75
201 +
202 +0x03: LDDS20
203 +
204 +0x04: LLMS01
205 +
206 +0x05: LSPH01
207 +
208 +0x06: LSNPK01
209 +
210 +
211 +