... ... @@ -54,25 +54,6 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 -= Configure GroPoint Air to Connect LoRaWAN Network =
58 -
59 -
60 -== LED Indicator  ( 检查等状态是否对的) ==
61 -
62 -The GroPoint Air has an internal LED which can show the status of different states.
63 -
64 -* The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
65 -* Blink once when device transmits a packet.
66 -
67 -
68 -== Firmware and Changelog (Changelog标注现在 版本是什么版本) ==
69 -
70 -Firmware Download Location: [[https:~~/~~/www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0>>https://www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0]]
71 -
72 -Change Log:
73 -
74 -
75 -
76 76  = Configure GroPoint Air via AT Command or LoRaWAN Downlink =
77 77  
78 78  Use can configure GroPoint Air via AT Command or LoRaWAN Downlink.
... ... @@ -88,8 +88,12 @@
88 88  
89 89  These commands are to configure:
90 90  
91 -* General system settings like: uplink interval.
92 -* LoRaWAN protocol & radio-related command.
72 +* (((
73 +General system settings like: uplink interval.
74 +)))
75 +* (((
76 +LoRaWAN protocol & radio-related command.
77 +)))
93 93  
94 94  They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
95 95  
... ... @@ -114,9 +114,15 @@
114 114  
115 115  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
116 116  
117 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
118 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
102 +* (((
103 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
104 +)))
105 +* (((
106 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
119 119  
108 +
109 +)))
110 +
120 120  == 3.2 Set Interrupt Mode  (是否存在) ==
121 121  
122 122  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -131,8 +131,12 @@
131 131  
132 132  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
133 133  
134 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
135 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
125 +* (((
126 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
127 +)))
128 +* (((
129 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
130 +)))