From version < 36.1 >
edited by Edwin Chen
on 2022/06/08 23:58
To version < 41.1 >
edited by David Huang
on 2022/06/11 16:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.David
Content
... ... @@ -54,11 +54,20 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 += Connect LoRaWAN Network =
57 57  
58 -== Firmware and Changelog: ==
59 59  
60 -Firmware Download Location: [[https:~~/~~/www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0>>https://www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0]]
60 +== LED Indicator ==
61 61  
62 +The GroPoint Air has an internal LED which can show the status of different states.
63 +
64 +* The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
65 +* Blink once when device transmits a packet.
66 +
67 +== Firmware and Changelog ==
68 +
69 +Firmware Download Location: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/GroPoint_Air/firmware/>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/GroPoint_Air/firmware/]]
70 +
62 62  Change Log:
63 63  
64 64  
... ... @@ -107,7 +107,7 @@
107 107  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
108 108  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
109 109  
110 -== 3.2 Set Interrupt Mode  (是否存在) ==
119 +== 3.2 Set Interrupt Mode ==
111 111  
112 112  Feature, Set Interrupt mode for GPIO_EXIT.
113 113  
... ... @@ -124,7 +124,7 @@
124 124  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
125 125  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
126 126  
127 -== 3.3 Get Firmware Version Info ~-~--(是否存在) ==
136 +== 3.3 Get Firmware Version Info ==
128 128  
129 129  Feature: use downlink to get firmware version.
130 130  
... ... @@ -141,7 +141,7 @@
141 141  
142 142  |=(((
143 143  **Size(bytes)**
144 -)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
153 +)))|=**1**|=**1**|=**1**|=**2**|=**1**|=4|=**1**
145 145  |**Value**|Software Type|(((
146 146  Frequency
147 147  
... ... @@ -177,8 +177,10 @@
177 177  
178 178  *0x09: AS923-2
179 179  
180 -*0xa0: AS923-3
189 +*0x0A: AS923-3
181 181  
191 +*0x0B: AS923-4
192 +
182 182  **Sub-Band**: value 0x00 ~~ 0x08
183 183  
184 184  **Firmware Version**: 0x0100, Means: v1.0.0 version
... ... @@ -197,7 +197,9 @@
197 197  
198 198  0x06: LSNPK01
199 199  
211 +0x07: LDDS45
200 200  
213 +0x08: LSLP01
201 201  
202 202  = Use AT Command =
203 203  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0