<
From version < 35.1 >
edited by Edwin Chen
on 2022/06/08 23:55
To version < 33.1 >
edited by Edwin Chen
on 2022/06/08 23:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -61,7 +61,7 @@
61 61  * AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
62 62  * LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
63 63  
64 -There are two kinds of commands to configure GroPoint Air, they are:
64 +There are two kinds of commands to configure GroPoint, they are:
65 65  
66 66  * (((
67 67  **~ General Commands**.
... ... @@ -69,17 +69,21 @@
69 69  
70 70  These commands are to configure:
71 71  
72 -* General system settings like: uplink interval.
73 -* LoRaWAN protocol & radio-related command.
72 +* (((
73 +General system settings like: uplink interval.
74 +)))
75 +* (((
76 +LoRaWAN protocol & radio-related command.
77 +)))
74 74  
75 75  They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
76 76  
77 77  
78 78  * (((
79 -**~ Commands special design for GroPoint Air**
83 +**~ Commands special design for LLMS01**
80 80  )))
81 81  
82 -These commands only valid for GroPoint Air, as below:
86 +These commands only valid for LLMS01, as below:
83 83  
84 84  == 3.1 Set Transmit Interval Time ==
85 85  
... ... @@ -95,9 +95,14 @@
95 95  
96 96  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
97 97  
98 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
99 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
102 +* (((
103 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
104 +)))
105 +* (((
106 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
100 100  
108 +
109 +)))
101 101  
102 102  == 3.2 Set Interrupt Mode  (是否存在) ==
103 103  
... ... @@ -113,10 +113,13 @@
113 113  
114 114  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
115 115  
116 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
117 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
125 +* (((
126 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
127 +)))
128 +* (((
129 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
130 +)))
118 118  
119 -
120 120  == 3.3 Get Firmware Version Info ~-~--(是否存在) ==
121 121  
122 122  Feature: use downlink to get firmware version.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0