... ... @@ -61,7 +61,7 @@
61 61  * AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
62 62  * LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
63 63  
64 -There are two kinds of commands to configure GroPoint, they are:
64 +There are two kinds of commands to configure GroPoint Air, they are:
65 65  
66 66  * (((
67 67  **~ General Commands**.
... ... @@ -69,21 +69,17 @@
69 69  
70 70  These commands are to configure:
71 71  
72 -* (((
73 -General system settings like: uplink interval.
74 -)))
75 -* (((
76 -LoRaWAN protocol & radio-related command.
77 -)))
72 +* General system settings like: uplink interval.
73 +* LoRaWAN protocol & radio-related command.
78 78  
79 79  They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
80 80  
81 81  
82 82  * (((
83 -**~ Commands special design for LLMS01**
79 +**~ Commands special design for GroPoint Air**
84 84  )))
85 85  
86 -These commands only valid for LLMS01, as below:
82 +These commands only valid for GroPoint Air, as below:
87 87  
88 88  == 3.1 Set Transmit Interval Time ==
89 89  
... ... @@ -99,14 +99,9 @@
99 99  
100 100  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
101 101  
102 -* (((
103 -Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
104 -)))
105 -* (((
106 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
98 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
99 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
107 107  
108 -
109 -)))
110 110  
111 111  == 3.2 Set Interrupt Mode  (是否存在) ==
112 112  
... ... @@ -122,13 +122,10 @@
122 122  
123 123  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
124 124  
125 -* (((
126 -Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
127 -)))
128 -* (((
129 -Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
130 -)))
116 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
117 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
131 131  
119 +
132 132  == 3.3 Get Firmware Version Info ~-~--(是否存在) ==
133 133  
134 134  Feature: use downlink to get firmware version.