Changes for page CPN01- NB-IoT Outdoor Open/Close Dry Contact Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -59,6 +59,7 @@ 59 59 * 8500mAh Battery for long-term use 60 60 61 61 62 + 62 62 == 1.3 Specification == 63 63 64 64 ... ... @@ -77,6 +77,7 @@ 77 77 * B28 @H-FDD: 700MHz 78 78 79 79 81 + 80 80 == 1.4 Installation == 81 81 82 82 ... ... @@ -88,7 +88,6 @@ 88 88 [[image:image-20221117175717-1.png||height="323" width="861"]] 89 89 90 90 91 - 92 92 == 1.5 Applications == 93 93 94 94 ... ... @@ -97,6 +97,7 @@ 97 97 * Dry Contact Detection 98 98 99 99 101 + 100 100 == 1.6 Mechanical == 101 101 102 102 ... ... @@ -371,6 +371,7 @@ 371 371 * (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,....... 372 372 373 373 376 + 374 374 == 2.4 Payload Explanation and Sensor Interface == 375 375 376 376 === 2.4.1 Device ID === ... ... @@ -481,11 +481,11 @@ 481 481 482 482 By default, CPN01 prints the downlink payload to console port. 483 483 484 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:5 20px" %)485 -|(% style="width:2 26px" %)**Downlink Control Type**|(% style="width:25px" %)**FPort**|(% style="width:98px" %)**Type Code**|(% style="width:147px" %)**Downlink payload size(bytes)**486 -|(% style="width:2 26px" %)TDC(Transmit Time Interval)|(% style="width:25px" %)Any|(% style="width:98px" %)01|(% style="width:147px" %)4487 -|(% style="width:2 26px" %)RESET|(% style="width:25px" %)Any|(% style="width:98px" %)04|(% style="width:147px" %)2488 -|(% style="width:2 26px" %)INTMOD|(% style="width:25px" %)Any|(% style="width:98px" %)06|(% style="width:147px" %)4487 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:505px" %) 488 +|(% style="width:207px" %)**Downlink Control Type**|(% style="width:56px" %)**FPort**|(% style="width:93px" %)**Type Code**|(% style="width:144px" %)**Downlink payload size(bytes)** 489 +|(% style="width:207px" %)TDC(Transmit Time Interval)|(% style="width:56px" %)Any|(% style="width:93px" %)01|(% style="width:144px" %)4 490 +|(% style="width:207px" %)RESET|(% style="width:56px" %)Any|(% style="width:93px" %)04|(% style="width:144px" %)2 491 +|(% style="width:207px" %)INTMOD|(% style="width:56px" %)Any|(% style="width:93px" %)06|(% style="width:144px" %)4 489 489 490 490 491 491 **Examples:** ... ... @@ -517,6 +517,7 @@ 517 517 * For each uplink probe, LED will be on for 500ms. 518 518 519 519 523 + 520 520 == 2.7 Alarm Base on Timeout == 521 521 522 522 ... ... @@ -568,9 +568,15 @@ 568 568 569 569 (% style="color:blue" %)**AT Command: AT+CLRDTA** 570 570 571 -[[image:image-20221021111527-19.png]] 572 572 576 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:498px" %) 577 +|(% style="width:158px" %)**Command Example**|(% style="width:169px" %)**Function**|(% style="width:167px" %)**Response** 578 +|(% style="width:158px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|(% style="width:167px" %)((( 579 +Clear all stored sensor data…OK 580 +))) 573 573 582 + 583 + 574 574 == 2.10 Set trigger mode == 575 575 576 576 ... ... @@ -578,9 +578,13 @@ 578 578 579 579 Feature: Set the trigger interrupt mode. 580 580 581 -[[image:image-20221021111552-20.png]] 591 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:472px" %) 592 +|(% style="width:158px" %)**Command Example**|(% style="width:225px" %)**Function**|(% style="width:88px" %)**Response** 593 +|(% style="width:158px" %)AT+TTRMOD=1|(% style="width:225px" %)Count and trigger from open to close (rising edge)|(% style="width:88px" %)OK 594 +|(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK 582 582 583 583 597 + 584 584 == 2.11 Set the calculate flag == 585 585 586 586 ... ... @@ -588,9 +588,14 @@ 588 588 589 589 (% style="color:blue" %)**AT Command: AT+CALCFLAG** 590 590 591 -[[image:image-20221021111711-22.png]] 592 592 606 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:430px" %) 607 +|(% style="width:158px" %)**Command Example**|(% style="width:196px" %)**Function**|(% style="width:74px" %)**Response** 608 +|(% style="width:158px" %)AT+CALCFLAG=1|(% style="width:196px" %)Set the calculate flag to 1|(% style="width:74px" %)OK 609 +|(% style="width:158px" %)AT+CALCFLAG=2|(% style="width:196px" %)Set the calculate flag to 2|(% style="width:74px" %)OK 593 593 611 + 612 + 594 594 == 2.12 Set count number == 595 595 596 596 ... ... @@ -598,9 +598,14 @@ 598 598 599 599 (% style="color:blue" %)**AT Command: AT+SETCNT** 600 600 601 -[[image:image-20221021111748-24.png]] 602 602 621 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:459px" %) 622 +|(% style="width:158px" %)**Command Example**|(% style="width:239px" %)**Function**|(% style="width:85px" %)**Response** 623 +|(% style="width:158px" %)AT+SETCNT=0|(% style="width:239px" %)Set the count number to 0|(% style="width:85px" %)OK 624 +|(% style="width:158px" %)AT+SETCNT=100|(% style="width:239px" %)Set the count number to 100|(% style="width:85px" %)OK 603 603 626 + 627 + 604 604 == 2.13 Set the number of data to be uploaded and the recording time == 605 605 606 606 ... ... @@ -828,6 +828,7 @@ 828 828 * Weight: 420g 829 829 830 830 855 + 831 831 = 9. Support = 832 832 833 833