<
From version < 54.10 >
edited by Xiaoling
on 2022/12/15 15:14
To version < 54.11 >
edited by Xiaoling
on 2023/04/04 10:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -58,8 +58,6 @@
58 58  * Micro SIM card slot for NB-IoT SIM
59 59  * 8500mAh Battery for long-term use
60 60  
61 -
62 -
63 63  == 1.3  Specification ==
64 64  
65 65  
... ... @@ -77,8 +77,6 @@
77 77  * B20 @H-FDD: 800MHz
78 78  * B28 @H-FDD: 700MHz
79 79  
80 -
81 -
82 82  == 1.4  Installation ==
83 83  
84 84  
... ... @@ -97,8 +97,6 @@
97 97  * Pulse meter application
98 98  * Dry Contact Detection
99 99  
100 -
101 -
102 102  == 1.6  Mechanical ==
103 103  
104 104  
... ... @@ -372,8 +372,6 @@
372 372  
373 373  * (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,.......
374 374  
375 -
376 -
377 377  == 2.4  Payload Explanation and Sensor Interface ==
378 378  
379 379  === 2.4.1  Device ID ===
... ... @@ -490,7 +490,6 @@
490 490  |(% style="width:207px" %)RESET|(% style="width:56px" %)Any|(% style="width:93px" %)04|(% style="width:144px" %)2
491 491  |(% style="width:207px" %)INTMOD|(% style="width:56px" %)Any|(% style="width:93px" %)06|(% style="width:144px" %)4
492 492  
493 -
494 494  **Examples:**
495 495  
496 496  * (% style="color:#037691" %)**Set TDC**
... ... @@ -519,8 +519,6 @@
519 519  * After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
520 520  * For each uplink probe, LED will be on for 500ms.
521 521  
522 -
523 -
524 524  == 2.7  Alarm Base on Timeout ==
525 525  
526 526  
... ... @@ -563,8 +563,6 @@
563 563  |(% style="width:158px" %)AT+DEBUG=0|(% style="width:196px" %)Disable debug mode to 0|(% style="width:74px" %)OK
564 564  |(% style="width:158px" %)AT+DEBUG=1|(% style="width:196px" %)Enable debug mode to 1|(% style="width:74px" %)OK
565 565  
566 -
567 -
568 568  == 2.9  Clear Flash Record ==
569 569  
570 570  
... ... @@ -579,8 +579,6 @@
579 579  Clear all stored sensor data…OK
580 580  )))
581 581  
582 -
583 -
584 584  == 2.10  Set trigger mode ==
585 585  
586 586  
... ... @@ -593,8 +593,6 @@
593 593  |(% style="width:158px" %)AT+TTRMOD=1|(% style="width:225px" %)Count and trigger from open to close (rising edge)|(% style="width:88px" %)OK
594 594  |(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK
595 595  
596 -
597 -
598 598  == 2.11  Set the calculate flag ==
599 599  
600 600  
... ... @@ -608,8 +608,6 @@
608 608  |(% style="width:158px" %)AT+CALCFLAG=1|(% style="width:196px" %)Set the calculate flag to 1|(% style="width:74px" %)OK
609 609  |(% style="width:158px" %)AT+CALCFLAG=2|(% style="width:196px" %)Set the calculate flag to 2|(% style="width:74px" %)OK
610 610  
611 -
612 -
613 613  == 2.12 Set count number ==
614 614  
615 615  
... ... @@ -623,8 +623,6 @@
623 623  |(% style="width:158px" %)AT+SETCNT=0|(% style="width:239px" %)Set the count number to 0|(% style="width:85px" %)OK
624 624  |(% style="width:158px" %)AT+SETCNT=100|(% style="width:239px" %)Set the count number to 100|(% style="width:85px" %)OK
625 625  
626 -
627 -
628 628  == 2.13  Set the number of data to be uploaded and the recording time ==
629 629  
630 630  
... ... @@ -655,60 +655,14 @@
655 655  Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
656 656  
657 657  
658 -== 2.16  Battery Analysis ==
637 +== 2.16 Battery & Power Consumption ==
659 659  
660 -=== 2.16.1  ​Battery Type ===
661 661  
640 +CPN01 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
662 662  
663 -The CPN01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
642 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
664 664  
665 -The battery is designed to last for several years depends on the actual use environment and update interval. 
666 666  
667 -The battery-related documents as below:
668 -
669 -* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
670 -
671 -* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
672 -
673 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
674 -
675 -[[image:image-20221021111911-26.png]] ​
676 -
677 -
678 -=== 2.16.2  Power consumption Analyze ===
679 -
680 -
681 -Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
682 -
683 -Instruction to use as below:
684 -
685 -(% style="color:blue" %)**Step 1:  **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
686 -
687 -(% style="color:blue" %)**Step 2: **(%%) Open it and choose
688 -
689 -* Product Model
690 -
691 -* Uplink Interval
692 -
693 -* Working Mode
694 -
695 -And the Life expectation in difference case will be shown on the right.
696 -
697 -[[image:1666596205057-567.png]] ​
698 -
699 -
700 -=== 2.16.3  ​Battery Note ===
701 -
702 -
703 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
704 -
705 -
706 -=== 2.16.4  Replace the battery ===
707 -
708 -
709 -The default battery pack of CPN01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
710 -
711 -
712 712  = 3. ​ Access NB-IoT Module =
713 713  
714 714  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0