Changes for page CPN01- NB-IoT Outdoor Open/Close Dry Contact Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -90,7 +90,6 @@ 90 90 [[image:image-20221117175717-1.png||height="323" width="861"]] 91 91 92 92 93 - 94 94 == 1.5 Applications == 95 95 96 96 ... ... @@ -485,7 +485,11 @@ 485 485 486 486 By default, CPN01 prints the downlink payload to console port. 487 487 488 -[[image:image-20221021111414-18.png]] 487 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:505px" %) 488 +|(% style="width:207px" %)**Downlink Control Type**|(% style="width:56px" %)**FPort**|(% style="width:93px" %)**Type Code**|(% style="width:144px" %)**Downlink payload size(bytes)** 489 +|(% style="width:207px" %)TDC(Transmit Time Interval)|(% style="width:56px" %)Any|(% style="width:93px" %)01|(% style="width:144px" %)4 490 +|(% style="width:207px" %)RESET|(% style="width:56px" %)Any|(% style="width:93px" %)04|(% style="width:144px" %)2 491 +|(% style="width:207px" %)INTMOD|(% style="width:56px" %)Any|(% style="width:93px" %)06|(% style="width:144px" %)4 489 489 490 490 491 491 **Examples:** ... ... @@ -554,9 +554,14 @@ 554 554 555 555 (% style="color:blue" %)**AT Command: AT+DEBUG** 556 556 557 -[[image:image-20221021111629-21.png]] 558 558 561 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:430px" %) 562 +|(% style="width:158px" %)**Command Example**|(% style="width:196px" %)**Function**|(% style="width:74px" %)**Response** 563 +|(% style="width:158px" %)AT+DEBUG=0|(% style="width:196px" %)Disable debug mode to 0|(% style="width:74px" %)OK 564 +|(% style="width:158px" %)AT+DEBUG=1|(% style="width:196px" %)Enable debug mode to 1|(% style="width:74px" %)OK 559 559 566 + 567 + 560 560 == 2.9 Clear Flash Record == 561 561 562 562 ... ... @@ -564,9 +564,15 @@ 564 564 565 565 (% style="color:blue" %)**AT Command: AT+CLRDTA** 566 566 567 -[[image:image-20221021111527-19.png]] 568 568 576 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:498px" %) 577 +|(% style="width:158px" %)**Command Example**|(% style="width:169px" %)**Function**|(% style="width:167px" %)**Response** 578 +|(% style="width:158px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|(% style="width:167px" %)((( 579 +Clear all stored sensor data…OK 580 +))) 569 569 582 + 583 + 570 570 == 2.10 Set trigger mode == 571 571 572 572 ... ... @@ -574,9 +574,13 @@ 574 574 575 575 Feature: Set the trigger interrupt mode. 576 576 577 -[[image:image-20221021111552-20.png]] 591 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:472px" %) 592 +|(% style="width:158px" %)**Command Example**|(% style="width:225px" %)**Function**|(% style="width:88px" %)**Response** 593 +|(% style="width:158px" %)AT+TTRMOD=1|(% style="width:225px" %)Count and trigger from open to close (rising edge)|(% style="width:88px" %)OK 594 +|(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK 578 578 579 579 597 + 580 580 == 2.11 Set the calculate flag == 581 581 582 582 ... ... @@ -584,9 +584,14 @@ 584 584 585 585 (% style="color:blue" %)**AT Command: AT+CALCFLAG** 586 586 587 -[[image:image-20221021111711-22.png]] 588 588 606 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:430px" %) 607 +|(% style="width:158px" %)**Command Example**|(% style="width:196px" %)**Function**|(% style="width:74px" %)**Response** 608 +|(% style="width:158px" %)AT+CALCFLAG=1|(% style="width:196px" %)Set the calculate flag to 1|(% style="width:74px" %)OK 609 +|(% style="width:158px" %)AT+CALCFLAG=2|(% style="width:196px" %)Set the calculate flag to 2|(% style="width:74px" %)OK 589 589 611 + 612 + 590 590 == 2.12 Set count number == 591 591 592 592 ... ... @@ -594,9 +594,14 @@ 594 594 595 595 (% style="color:blue" %)**AT Command: AT+SETCNT** 596 596 597 -[[image:image-20221021111748-24.png]] 598 598 621 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:459px" %) 622 +|(% style="width:158px" %)**Command Example**|(% style="width:239px" %)**Function**|(% style="width:85px" %)**Response** 623 +|(% style="width:158px" %)AT+SETCNT=0|(% style="width:239px" %)Set the count number to 0|(% style="width:85px" %)OK 624 +|(% style="width:158px" %)AT+SETCNT=100|(% style="width:239px" %)Set the count number to 100|(% style="width:85px" %)OK 599 599 626 + 627 + 600 600 == 2.13 Set the number of data to be uploaded and the recording time == 601 601 602 602