... ... @@ -372,8 +372,6 @@
372 372  
373 373  * (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,.......
374 374  
375 -
376 -
377 377  == 2.4  Payload Explanation and Sensor Interface ==
378 378  
379 379  === 2.4.1  Device ID ===
... ... @@ -518,8 +518,6 @@
518 518  * After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
519 519  * For each uplink probe, LED will be on for 500ms.
520 520  
521 -
522 -
523 523  == 2.7  Alarm Base on Timeout ==
524 524  
525 525  
... ... @@ -562,8 +562,6 @@
562 562  |(% style="width:158px" %)AT+DEBUG=0|(% style="width:196px" %)Disable debug mode to 0|(% style="width:74px" %)OK
563 563  |(% style="width:158px" %)AT+DEBUG=1|(% style="width:196px" %)Enable debug mode to 1|(% style="width:74px" %)OK
564 564  
565 -
566 -
567 567  == 2.9  Clear Flash Record ==
568 568  
569 569  
... ... @@ -578,8 +578,6 @@
578 578  Clear all stored sensor data…OK
579 579  )))
580 580  
581 -
582 -
583 583  == 2.10  Set trigger mode ==
584 584  
585 585  
... ... @@ -592,8 +592,6 @@
592 592  |(% style="width:158px" %)AT+TTRMOD=1|(% style="width:225px" %)Count and trigger from open to close (rising edge)|(% style="width:88px" %)OK
593 593  |(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK
594 594  
595 -
596 -
597 597  == 2.11  Set the calculate flag ==
598 598  
599 599  
... ... @@ -607,8 +607,6 @@
607 607  |(% style="width:158px" %)AT+CALCFLAG=1|(% style="width:196px" %)Set the calculate flag to 1|(% style="width:74px" %)OK
608 608  |(% style="width:158px" %)AT+CALCFLAG=2|(% style="width:196px" %)Set the calculate flag to 2|(% style="width:74px" %)OK
609 609  
610 -
611 -
612 612  == 2.12 Set count number ==
613 613  
614 614  
... ... @@ -622,8 +622,6 @@
622 622  |(% style="width:158px" %)AT+SETCNT=0|(% style="width:239px" %)Set the count number to 0|(% style="width:85px" %)OK
623 623  |(% style="width:158px" %)AT+SETCNT=100|(% style="width:239px" %)Set the count number to 100|(% style="width:85px" %)OK
624 624  
625 -
626 -
627 627  == 2.13  Set the number of data to be uploaded and the recording time ==
628 628  
629 629  
... ... @@ -785,6 +785,12 @@
785 785  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string.
786 786  
787 787  
774 +== 6.3 Not able to connect to NB-IoT network and keep showing "Signal Strength:99". ==
775 +
776 +
777 +This means sensor is trying to join the NB-IoT network but fail. Please see this link for **//[[trouble shooting for signal strenght:99>>doc:Main.CSQ\:99,99.WebHome]]//**.