... ... @@ -59,7 +59,6 @@
59 59  * 8500mAh Battery for long-term use
60 60  
61 61  
62 -
63 63  == 1.3  Specification ==
64 64  
65 65  
... ... @@ -78,7 +78,6 @@
78 78  * B28 @H-FDD: 700MHz
79 79  
80 80  
81 -
82 82  == 1.4  Installation ==
83 83  
84 84  
... ... @@ -98,7 +98,6 @@
98 98  * Dry Contact Detection
99 99  
100 100  
101 -
102 102  == 1.6  Mechanical ==
103 103  
104 104  
... ... @@ -373,7 +373,6 @@
373 373  * (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,.......
374 374  
375 375  
376 -
377 377  == 2.4  Payload Explanation and Sensor Interface ==
378 378  
379 379  === 2.4.1  Device ID ===
... ... @@ -519,7 +519,6 @@
519 519  * For each uplink probe, LED will be on for 500ms.
520 520  
521 521  
522 -
523 523  == 2.7  Alarm Base on Timeout ==
524 524  
525 525  
... ... @@ -563,7 +563,6 @@
563 563  |(% style="width:158px" %)AT+DEBUG=1|(% style="width:196px" %)Enable debug mode to 1|(% style="width:74px" %)OK
564 564  
565 565  
566 -
567 567  == 2.9  Clear Flash Record ==
568 568  
569 569  
... ... @@ -579,7 +579,6 @@
579 579  )))
580 580  
581 581  
582 -
583 583  == 2.10  Set trigger mode ==
584 584  
585 585  
... ... @@ -593,7 +593,6 @@
593 593  |(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK
594 594  
595 595  
596 -
597 597  == 2.11  Set the calculate flag ==
598 598  
599 599  
... ... @@ -608,7 +608,6 @@
608 608  |(% style="width:158px" %)AT+CALCFLAG=2|(% style="width:196px" %)Set the calculate flag to 2|(% style="width:74px" %)OK
609 609  
610 610  
611 -
612 612  == 2.12 Set count number ==
613 613  
614 614  
... ... @@ -623,7 +623,6 @@
623 623  |(% style="width:158px" %)AT+SETCNT=100|(% style="width:239px" %)Set the count number to 100|(% style="width:85px" %)OK
624 624  
625 625  
626 -
627 627  == 2.13  Set the number of data to be uploaded and the recording time ==
628 628  
629 629  
... ... @@ -785,6 +785,12 @@
785 785  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string.
786 786  
787 787  
778 +== 6.3 Not able to connect to NB-IoT network and keep showing "Signal Strength:99". ==
779 +
780 +
781 +This means sensor is trying to join the NB-IoT network but fail. Please see this link for **//[[trouble shooting for signal strenght:99>>doc:Main.CSQ\:99,99.WebHome]]//**.
782 +
783 +
788 788  = 7. ​ Order Info =
789 789  
790 790  
... ... @@ -805,7 +805,6 @@
805 805  * Weight:   420g
806 806  
807 807  
808 -
809 809  = 9.  Support =
810 810  
811 811  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved