LoRaST v4 base Hardware

Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade.

ModelMother BoardUART for AT CommandsUART for Upgrade Firmware

PS-LB 

SIBInstructionInstruction

UART for AT Commands

Generate software set up for AT Commands via UART

  1. Use a general serial tool.
  2. Connect PC to device's UART interface
  3. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.

image-20221224170218-1.png

UART Connection for SIB mother board

image-20221224171304-3.png

UART for Firmware Upgrade

General Instruction for UART update firmware

LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:

     Step1: Set BOOT Switch to PROG mode. PROG mode is for update firmware specially.

     Step2: Press Reset button, the module will then boot into program mode. 

     Step3: Use TremoProgrammer to update the firmware to LoRaST v4.

     Step4: Set BOOT Switch to FLASH position. Press Reset button again and module will run the new software.

Below is the method for how to update via TremoProgrammer:

1.  Software download link:  https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0

2.  Run TremoProgrammer.

3.  Choose software and set the address to 0x0800D000

4. Rember to set BOOT Switch to FLASH after update

image-20221224174341-4.png

UART Connection for SIB mother board for Program.

Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.