... ... @@ -195,15 +195,23 @@
195 195  
196 196  == 5.2 See Debug Info ==
197 197  
198 +(((
198 198  **For LoRaWAN Server**
200 +)))
199 199  
202 +(((
200 200  We can check if there is downlink message for this end node, use TTN for example:
204 +)))
201 201  
206 +(((
202 202  Configure a downstream to the end device
208 +)))
203 203  
204 204  [[image:https://wiki.dragino.com/images/thumb/8/82/Downstream_debug_1.png/600px-Downstream_debug_1.png||height="217" width="600"]]
205 205  
212 +(((
206 206  Set a downstream in TTN and see it is sent
214 +)))
207 207  
208 208  
209 209  (((
... ... @@ -212,10 +212,14 @@
212 212  
213 213  [[image:https://wiki.dragino.com/images/thumb/d/dc/Downstream_debug_2.png/600px-Downstream_debug_2.png||height="245" width="600"]]
214 214  
223 +(((
215 215  Gateway Traffic can see this downstream info
225 +)))
216 216  
217 217  
228 +(((
218 218  **For LoRaWAN Gateway**
230 +)))
219 219  
220 220  (((
221 221  When the downstream packet appear on the traffic of Gateway page. The LoRaWAN gateway can get it from LoRaWAN server and transmit it. In Dragion Gateway, this can be checked by runinng "logread -f" in the SSH console. and see below:
... ... @@ -223,10 +223,14 @@
223 223  
224 224  [[image:https://wiki.dragino.com/images/thumb/2/21/Downstream_debug_3.png/600px-Downstream_debug_3.png||height="195" width="600"]]
225 225  
238 +(((
226 226  Gateway Sent out this packet
240 +)))
227 227  
228 228  
243 +(((
229 229  **For End Node**
245 +)))
230 230  
231 231  we can use AT Command (AT+CFG) to check the RX1 configure and RX2 configure. as below:
232 232  
... ... @@ -250,45 +250,38 @@
250 250   AT+RX2DL=2000 ~-~--> Receive Delay 2
251 251  )))
252 252  
253 -(((
254 254  **when the device running, we can see below info:**
255 -)))
256 256  
257 257  (((
258 258  
259 259  )))
260 260  
261 -(% class="box" %)
262 -(((
263 - [12502]~*~*~*~** UpLinkCounter= 0 ~*~*~*~**
275 +{{{ [12502]***** UpLinkCounter= 0 *****
264 264   [12503]TX on freq 868500000 Hz at DR 0
265 265   [13992]txDone
266 - [15022]RX on freq 868500000 Hz at DR 0     ~-~-> RX1 window open at frequency: 868500000, DR0, after 15022-13992= 1030ms of txdone
267 - [15222]rxTimeOut                           ~-~-> no packet arrive in RX1 window. (duration: 200ms)
268 - [15987]RX on freq 869525000 Hz at DR 3     ~-~-> RX2 window open at frequency: 869525000, DR3, after 15987-13992= 1995ms of txdone
269 - [16027]rxTimeOut                           ~-~-> no packet arrive in RX2 window. (duration: 40 ms)
270 -)))
278 + [15022]RX on freq 868500000 Hz at DR 0 --> RX1 window open at frequency: 868500000, DR0, after 15022-13992= 1030ms of txdone
279 + [15222]rxTimeOut --> no packet arrive in RX1 window. (duration: 200ms)
280 + [15987]RX on freq 869525000 Hz at DR 3 --> RX2 window open at frequency: 869525000, DR3, after 15987-13992= 1995ms of txdone
281 + [16027]rxTimeOut --> no packet arrive in RX2 window. (duration: 40 ms)}}}
271 271  
272 272  (((
273 273  
274 274  )))
275 275  
276 -(((
277 277  **Another message:**
278 -)))
279 279  
289 +{{{
290 + [12502]***** UpLinkCounter= 0 *****
291 + [12503]TX on freq 868100000 Hz at DR 0
292 + [13992]txDone
293 + [15022]RX on freq 868100000 Hz at DR 0
294 + [15222]rxTimeOut
295 + [15987]RX on freq 869525000 Hz at DR 3
296 + [16185]rxDone --> We have got the downstream packet.
297 + Rssi= -64
298 + Receive data
299 + 1:0012345678}}}
280 280  
281 - [12502]~*~*~*~** UpLinkCounter= 0 ~*~*~*~**
282 - [12503]TX on freq 868100000 Hz at DR 0
283 - [13992]txDone
284 - [15022]RX on freq 868100000 Hz at DR 0
285 - [15222]rxTimeOut
286 - [15987]RX on freq 869525000 Hz at DR 3
287 - [16185]rxDone                              ~-~-> We have got the downstream packet.
288 - Rssi= -64
289 - Receive data
290 - 1:0012345678
291 -
292 292  == 5.3 If problem doesn’t solve ==
293 293  
294 294  **If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the sceenshots for each step to check. They include:**
... ... @@ -317,6 +317,10 @@
317 317  )))
318 318  
319 319  (((
329 +
330 +)))
331 +
332 +(((
320 320  In this case, please double check the gateway frequency and the server frequency band.
321 321  )))
322 322  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved