From version < 39.2 >
edited by Xiaoling
on 2023/03/23 17:08
To version < 40.1 >
edited by Bei Jinggeng
on 2023/04/23 10:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -215,7 +215,6 @@
215 215  * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). (% style="color:red" %)**This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.**
216 216  
217 217  
218 -
219 219  == 5.2 See Debug Info ==
220 220  
221 221  
... ... @@ -332,7 +332,6 @@
332 332  * End Node traffic (from server UI) to shows end node activity in server.
333 333  
334 334  
335 -
336 336  = 6. Downlink Issue ~-~- Packet REJECTED, unsupported frequency =
337 337  
338 338  
... ... @@ -461,13 +461,29 @@
461 461  
462 462  When using the frequency mentioned above, the server sometimes adjusts the Data Rate (DR) of the node, because the end node has Adaptive Data Rate (ADR) Enabled.
463 463  
462 +1.
463 +
464 464  When the server adjusts end node data rate to 0, the maximum payload length is 11 bytes. The server sometimes sends an ADR packet to the end node, and the node will reply to the server after receiving the ADR packet, but the number of payload bytes exceeds the limit, so it will send a normal uplink packet, and following an additional 00 data packet to handle this MAC command response.
465 465  
466 +2.
466 466  
468 +The server downlinks a calibration time package
469 +This calibration time packet will exceed the byte limit, causing its payload to become 00
470 +
467 467  (% style="color:blue" %)**How to solve:**
468 468  
469 -Solution: Use the decoder to filter out this 0x00 packet.
473 +Solution:
470 470  
475 +~1. Use the decoder to filter out this 0x00 packet.
476 +
477 +2. Data rate changed from DR3 to DR5, increasing upload byte length
478 +AT+ADR=0
479 +AT+DR=3
480 +
481 +Downlink:
482 +
483 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]]
484 +
471 471  Some node decoders may not have the filter function, or you need decoders of other servers and formats. Please send an email to [[support@dragino.com>>mailto:support@dragino.com]]
472 472  
473 473  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0