... ... @@ -205,7 +205,6 @@
205 205  * This packet must match the frequency of the RX1 or RX2 window.
206 206  * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). (% style="color:red" %)**This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.**
207 207  
208 -
209 209  == 5.2 See Debug Info ==
210 210  
211 211  
... ... @@ -263,20 +263,15 @@
263 263  )))
264 264  
265 265  (((
265 +(% style="color:#037691" %)**AT+RX2FQ=869525000**  (%%) **~-~-->**  The RX2 Window frequency
266 +(% style="color:#037691" %)**AT+RX2DR=3**          (%%) **~-~-->**  The RX2 DataRate
267 +(% style="color:#037691" %)**AT+RX1DL=1000**       (%%) ** ~-~-->**  Receive Delay 1
268 +(% style="color:#037691" %)**AT+RX2DL=2000**       (%%) **~-~--> ** Receive Delay 2
269 +
266 266  
267 267  )))
268 268  
269 269  (((
270 -(% class="box infomessage" %)
271 -(((
272 -AT+RX2FQ=869525000     ~-~--> The RX2 Window frequency
273 -AT+RX2DR=3      ~-~--> The RX2 DataRate
274 -AT+RX1DL=1000   ~-~--> Receive Delay 1
275 -AT+RX2DL=2000   ~-~--> Receive Delay 2
276 -)))
277 -)))
278 -
279 -(((
280 280  (% style="color:blue" %)**when the device running, we can see below info:**
281 281  )))
282 282  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved